4.5
Intelligent Function Module Switch Setting
This section describes the intelligent function module switch setting.
The switch setting is made on the [I/O assignment] screen of GX Developer.
(1) Intelligent function module switch setting
The switch has five switches and is set at 16-bit data.
When the switch setting is not made, the default values of the switches from 1 to 5 are
0.
Table 4.7 Intelligent function module switches
Setting item
Setting value
Default value
Switch 1
Pulse input mode
Pulse input mode (Refer to Section 5.1.1.)
0
H
: 1 multiple of 1 phase
1
H
: 2 multiples of 1 phase
2
H
: CW/CCW
3
H
: 1 multiple of 2 phases
4
H
: 2 multiples of 2 phases
5
H
: 4 multiples of 2 phases
0000
H
Switch 2
Pulse input mode
0000
H
Switch 3
Counting speed setting
Counting speed setting (Refer to Section 3.1.)
Set the following bit pattern with hexadecimal.
00: 10 kPPS
01: 100 kPPS
10: 200 kPPS
Example) CH1 and 2: 200 kPPS, CH3: 100 kPPS, and
CH4 to 6 : 10 kPPS
00 00 00 01 10 10 001A
H
0000
H
Switch 4
Counter format, present value
selection setting
Counter format (Refer to Section 5.2.1 and Section
5.2.2.)
Set the following bit pattern with hexadecimal.
0: Linear counter
1: Ring counter
Example) Linear counter: CH1, CH2, and CH5
Ring counter: CH3, CH4, and CH6
00101100
2C
H
0000
H
Present value selection setting (Refer to Section 3.4.2
(5).)
0: Present value A (Un\G10 and 11)
1: Present value B (Un\G200 and 201)
Switch 5
Reserved: Fixed to 0.
H
CH4 CH3 CH2
CH1
H
0 0
Reserved:
Fixed to 0
CH6
CH5
H
0
Reserved: Fixed to 0
CH1
CH2
CH3
CH4
CH5
CH6
b11
b8 b7
b0
H
0
Reserved: Fixed to 0
0 0
CH CH CH CH CH CH
6
5
4
3
2
1
b7
b0