11. Removing the high pressure switch (63H)
(1) Remove the service panel. (See Photo 1)
(2) Remove the top panel. (See Photo 1)
(3) Remove the cover panel. (See Photo 1)
(4) Remove the stay and the side panel (R). (Refer to
Procedure 9)
(5) Remove the electrical parts box (Refer to Procedure 3).
(6) Pull out the lead wire of high pressure switch.
(7) Recover refrigerant.
(8) Remove the welded part of high pressure switch.
Note1: Recover refrigerant without letting it out in the air.
Note2: Access to the welded part becomes easier by
removing the right side panel.
Note3: When installing the high pressure switch, make
sure to cover it with a wet cloth to prevent it from
heating (100°C or more), then braze the pipes so
that the inside of pipes are not oxidized.
Photo 11
12. Removing the pressure sensor (63HS)
(1) Remove the service panel. (See Photo 1)
(2) Remove the top panel. (See Photo 1)
(3) Remove the stay and the side panel (R). (Refer to
Procedure 9)
(4) Pull out the lead wire of pressure sensor.
(5) Remove the electrical parts box (Refer to Procedure 3).
(6) Recover refrigerant.
(7) Remove the welded part of pressure sensor.
Note1: Recover refrigerant without letting it out in the air.
Note2: Access to the welded part becomes easier by
removing the right side panel.
Note3: When installing the pressure sensor, make sure to
cover it with a wet cloth to prevent it from heating
(100°C or more), then braze the pipes so that the
inside of pipes are not oxidized.
Photo 12
13. Removing the compressor (MC)
(1) Remove the service panel. (See Photo 1)
(2) Remove the top panel. (See Photo 1)
(3) Remove the cover panel. (See photo 1)
(4) Remove the stay and the side panel (R). (Refer to Procedure 9)
(5) Remove the electrical parts box. (Refer to Procedure 3)
(6) Remove the soundproof cover and lid.
(7) Remove the Comp. surface thermistor (TH33) (Photo 7)
(8) Remove the terminal cover and remove the lead wire for
compressor.
(9) Recover refrigerant.
(10
) Remove the 3 points of the compressor fixing nut using a
spanner or a adjustable wrench.
(11
) Remove the welded pipe of the compressor, then remove
the compressor.
Note1 : Recover refrigerant without letting it out in the air.
Note2 : When replacing the soundproof lid, fit the lid to
the wrapped cover without making a gap.
Photo 13
69
OCH727
High pressure
switch (63H)
Pressure sensor (63HS)
Compressor
fixing nuts
Compressor
(MC)
Terminal cover
Lead wire for
compressor
Lead wire of
comp. surface
thermistor
(TH33)
Содержание PUZ-WM112VAA
Страница 15: ...15 OCH727 6 WIRING DIAGRAM PUZ WM50VHA UK PUZ WM50VHA BS UK ...
Страница 16: ...16 OCH727 PUZ WM60VAA UK PUZ WM85VAA UK PUZ WM112VAA UK PUZ WM60VAA BS UK PUZ WM85VAA BS UK PUZ WM112VAA BS UK ...
Страница 17: ...17 OCH727 PUZ WM85YAA UK PUZ WM112YAA UK PUZ WM85YAA BS UK PUZ WM112YAA BS UK ...