background image

POUR L’INSTALLATEUR

FÜR INSTALLATEURE

FOR INSTALLER

Air to Water Heat Pump
PUHZ-W85VHA

MONTÖR 

İ

Ç

İ

N

ДЛЯ

 

УСТАНОВИТЕЛЯ

TIL INSTALLATØREN

FÖR INSTALLATÖREN

PARA O INSTALADOR

ΓΙΑ

 

ΑΥΤΟΝ

 

ΠΟΥ

 

ΚΑΝΕΙ

 

ΤΗΝ

 

ΕΓΚΑΤΑΣΤΑΣΗ

PER L’INSTALLATORE

PARA EL INSTALADOR

VOOR DE INSTALLATEUR

РУКОВОДСТВО

 

ПО

 

УСТАНОВКЕ

Для

 

обеспечения

 

безопасной

 

и

 

надлежащей

 

эксплуатации

 

внимательно

 

прочитайте

 

данное

 

руководство

 

и

 

руководство

 

по

 

установке

 

внутреннего

 

прибора

 

перед

 

установкой

 

прибора

.

INSTALLATIEHANDLEIDING

Lees deze handleiding en de installatiehandleiding van het binnenapparaat zorgvuldig door voordat u met het 
installeren van de unit begint.

MANUAL DE INSTALACIÓN

Para una utilización segura y correcta, lea este manual y el manual de instalación de la unidad interior 
atentamente antes de proceder a la instalación de la unidad.

MANUALE DI INSTALLAZIONE

Per un uso sicuro e corretto, leggere attentamente il presente manuale ed il manuale di installazione dell'unità 
interna prima di installare l'unità.

E

ΓΧ

EIPI

Δ

IO O

Δ

H

Γ

I

Ω

N E

Γ

KATA

Σ

TA

Σ

H

Σ

Για

 

ασφαλή

 

και

 

σωστή

 

χρήση

διαβάστε

 

προσεκτικά

 

αυτό

 

το

 

εγχειρίδιο

 

όπως

 

και

 

το

 

εγχειρίδιο

 

εγκατάστασης

 

της

 

εσωτερικής

 

μονάδας

 

προτού

 

εγκαταστήστε

 

τη

 

μονάδα

.

MANUAL DE INSTALAÇÃO

Para uma utilização segura e correcta, leia atentamente este manual e o manual de instalação da unidade 
interior antes de instalar a unidade.

INSTALLATIONSMANUAL

Læs af sikkerhedshensyn denne vejledning samt monteringsvejledningen til indendørsenheden grundigt, før 
De monterer enheden.

INSTALLATIONSMANUAL

Läs bruksanvisningen och inomhusenhetens installationshandbok noga innan enheten installeras så att den 
används på ett säkert och korrekt sätt. 

MONTAJ ELK

İ

TABI

Üniteyi kurmadan önce, güvenli ve do

ğ

ru kullanım için bu kılavuzu ve iç mekan ünitesi kullanım kılavuzunu 

dikkatle okuyun.

Türkçe

Русский

Nederlands

Español

Italiano

E

λληνικά

Português

Dansk

Svenska

INSTALLATION MANUAL

For safe and correct use, read this manual as well as the indoor unit installation manual thoroughly before 
installing the unit.

INSTALLATIONSHANDBUCH

Aus Sicherheitsgründen und zur richtigen Verwendung vor der Installation die vorliegende 
Bedienungsanleitung und die Installationsanleitung der Innenanlage gründlich durchlesen die Anlage.

MANUEL D’INSTALLATION

Avant d’installer l'unité, lire attentivement ce manuel, ainsi que le manuel d’installation de l’appareil intérieur 
pour une utilisation sûre et correcte.

English

Deutsch

Français

Содержание PUHZ-W85VHA

Страница 1: ...εγκατάστασης της εσωτερικής μονάδας προτού εγκαταστήστε τη μονάδα MANUAL DE INSTALAÇÃO Para uma utilização segura e correcta leia atentamente este manual e o manual de instalação da unidade interior antes de instalar a unidade INSTALLATIONSMANUAL Læs af sikkerhedshensyn denne vejledning samt monteringsvejledningen til indendørsenheden grundigt før De monterer enheden INSTALLATIONSMANUAL Läs bruksa...

Страница 2: ...rly installed it may cause water leakage electric shock or fire Do not remodel the unit Consult an installer for repairs If alterations or repairs are not performed correctly it may cause water leakage electric shock or fire The user should never attempt to repair the unit or transfer it to another location If the unit is installed improperly it may cause water leakage electric shock or fire If th...

Страница 3: ...unit is not properly grounded there may be a risk to get an electric shock Make sure to use circuit breakers ground fault interrupter isolating switch B fuse and molded case circuit breaker with the specified capacity If the circuit breaker capacity is larger than the specified capacity break down or fire may result 1 4 Before starting the test run Caution Turn on the main power switch more than 1...

Страница 4: ... shows three examples of precautions against strong winds 1 Face the air outlet towards the nearest available wall keeping about 50 cm dis tance Fig 2 2 2 Install an optional air guide if the unit is installed in a location where strong winds such as a typhoon etc may directly blow to the air outlet Fig 2 3 A Air outlet guide 3 Position the unit so that the outlet air can blow at right angle to th...

Страница 5: ...que at the water piping connection is 50 N m Check if water leaks after installation Use the water pressure in more than 0 MPa gauge and less than 0 3MPa gauge Use the inlet water of higher than 5 C and lower than 55 C 5 2 Water quality condition The water in a system should be clean and with a pH value of 6 5 8 0 The followings are the maximum values Calcium 100mg L Chlorine 100mg L Iron manganes...

Страница 6: ...S1 S2 S3 Warning In case of A control wiring there is high voltage potential on the S3 terminal caused by electrical circuit design that has no electrical insulation between power line and communication signal line Therefore please turn off the main power supply when servicing And do not touch the S1 S2 S3 terminals when the power is energized If isolator should be used between indoor unit and out...

Страница 7: ... CNDM connector option on the control board of the outdoor unit The ability varies according to the outdoor temperature and conditions etc 1 Complete the circuit as shown when using the external input adapter PAC SC36NA Option 2 SW1 ON Low noise mode SW1 OFF Normal operation A Circuit diagram example low noise mode B On site arrangement C External input adapter PAC SC36NA D Outdoor unit control bo...

Страница 8: ...act address telephone number on this manual before handing it to the customer This product is designed and intended for use in the residential commercial and light industrial environment The product at hand is based on the following EU regulations Low Voltage Directive 2006 95 EC Electromagnetic Compatibility Directive 2004 108 EC ...

Отзывы: