9
TROUBLESHOOTING
9-1. TROUBLESHOOTING
<Check code displayed by self-diagnosis and actions to be taken for service (summary)>
3UHVHQWDQGSDVWFKHFNFRGHVDUHORJJHGDQGWKH\FDQEHGLVSOD\HGRQWKHFRQWUROERDUGRIRXWGRRUXQLW$FWLRQVWREHWDNHQ
IRUVHUYLFHZKLFKGHSHQGVRQZKHWKHURUQRWWKHWURXEOHLVUHRFFXUULQJLQWKHILHOGDUHVXPPDUL]HGLQWKHWDEOHEHORZ&KHFN
WKHFRQWHQWVEHORZEHIRUHLQYHVWLJDWLQJGHWDLOV
Unit conditions at service
Check code
Actions to be taken for service (summary)
The trouble is reoccurring.
Displayed
Not displayed
Judge what is wrong and take a corrective action according
to “9-2. SELF-DIAGNOSIS ACTION TABLE”.
Conduct troubleshooting and ascertain the cause of the
trouble according to “9-3. TROUBLESHOOTING OF
PROBLEMS”.
The trouble is not reoccurring.
Logged
Not logged
1
Consider the temporary defects such as the work of
protection devices in the refrigerant circuit including
compressor, poor connection of wiring, noise, etc.
Re-check the symptom, and check the installation
environment, refrigerant amount, weather when the
trouble occurred, matters related to wiring, etc.
2
Reset check code logs and restart the unit after finishing
service.
3
There is no abnormality in electrical component,
controller board, remote controller, etc.
1
Re-check the abnormal symptom.
2
Conduct troubleshooting and ascertain the cause of the
trouble according to “9-3. TROUBLESHOOTING OF
PROBLEMS”.
3
Continue to operate unit for the time being if the cause
is not ascertained.
4
There is no abnormality concerning of parts such as
electrical component, controller board, remote controller,
etc.
OCH651