21
OPERATING PROCEDURE
PHOTOS
12. Removing the compressor
(1) Remove the service panel. (See Photo 1)
(2) Remove the top panel. (See Photo 1)
(3) Remove the electric parts box. (See Photo 3)
(4) Remove the bell mouth. (See Photo 7)
(5) Remove the 3 valve bed fixing screws (4
✕
10) and the
4 ball valve fixing screws(5
✕
16) to remove the valve bed.
(6) Remove the 3 rear panel fixing screws (5
✕
15) to the panel.
(7) Remove the cover panel fixing screw (5
✕
15) to remove
the front side of cover panel.
(8) Remove the 3 points of the compressor fixing nut with a
monkey wrench.
(9) Remove the braze part of compressor discharging / inlet.
13. Removing the accumulator.
(1) Remove the compressor. Or remove the rear panel.
(2) Remove the pipe of accumulator intake and outlet.
Photo 8
Compressor fixing nuts
Compressor
Accumulator