background image

7

PLFY-12NAMU-A

PLFY-20NAMU-A

PLFY-24NAMU-A

PLFY-32NAMU-A

PLFY-40NAMU-A

Single 208/230V 60Hz

12,000

20,000

24,000

32,000

40,000

13,000

22,500

26,500

36,000

39,000

10-3/16 (1-3/16)

11-3/4 (1-3/16)

33-1/16 (37-3/8)

33-1/16 (37-3/8)

49 (11)

53 (11)

66 (11)

390-420-460-490

490-530-570-640

530-570-640-710

710-810-920-990

780-880-990-1060

350-380-410-440

470-500-530-600

500-530-600-670

670-770-870-930

730-830-930-1000

24-27-28-30

27-28-31-33

28-30-33-34

34-36-40-41

37-40-43-44

6. Specifications

Model

Power source

Capacity

Cooling

<BTU/h>

Heating

<BTU/h>

Dimension (Grille)

H

<inch>

W

<inch>

D

<inch>

Net weight (Grille)

<Ibs>

DRY

<CFM>

WET

<CFM>

Noise level

(Low-Middle2-Middle1-High)

<dB(A)>

PLFY Series

Fan Airflow rate

(Low-Middle2-Middle1-High)

PKFY-08NAMU-A

PKFY-12NGMU-A

PKFY-20NFMU-A

PKFY-32NFMU-A

Single 208/230V 60Hz

8,000

12,000

20,000

32,000

9,000

13,500

22,500

35,500

11-5/8

13-3/8

13-3/8

32-3/32

39

55-1/8

66-1/8

6-7/32

9-1/4

9-1/4

19

35

53

62

170-180-200-210

280-340-370-410

490-640

780-990

160-170-180-190

250-300-330-370

440-570

700-890

32-33-35-36

32-36-40-42

39-45

46-49

Model

Power source

Capacity

Cooling

<BTU/h>

Heating

<BTU/h>

Dimension

H

<inch>

W

<inch>

D

<inch>

Net weight

<Ibs>

DRY

<CFM>

WET

<CFM>

Noise level

(Low-Middle2-Middle1-High)*1

<dB(A)>

PKFY Series

Fan Airflow rate

(Low-Middle2-Middle1-High)*1

*1 (Low-High) for PKFY-20/32NFMU-A

Содержание PLFY-NAMU-A

Страница 1: ...rs For Building Application INDOOR UNIT PLFY NAMU A PKFY NAMU A PKFY NGMU A PKFY NFMU A OPERATION MANUAL For safe and correct use please read this operation manual thoroughly before operating the air conditioner unit ...

Страница 2: ...the buttons as this may damage the remote controller Never wipe the remote controller with benzene thinner chemical rags etc Never block or cover the indoor or outdoor unit s intakes or outlets Warning Do not remove the front panel or the fan guard from the outdoor unit when it is running When you notice exceptionally abnormal noise or vibration stop operation turn off the power switch and contact...

Страница 3: ...door unit When a remote controller for one indoor unit is used to change modes at the same time as a different indoor unit is working together with the outdoor unit the operation underway stops and the new operation begins Until the old operation is complete the display on the remote controller flashes to indicate that the new operation is in waiting status Warning Check and confirm the power circ...

Страница 4: ... impossible PKFY NFMU A has 2 stage Low High 3 5 Adjusting the vertical airflow direction The vertical air vane helps select the vertical direction of the airflow 1 Press AIR DIRECTION button to select the vertical airflow direction Each time you press the button the option changes are displayed on the remote controller as shown below If the room temperature is higher than the temperature set on t...

Страница 5: ...ean the filters using a vacuum cleaner If you do not have a vacuum cleaner tap the filters against a solid object to knock off dirt and dust If the filters are especially dirty wash them in lukewarm water Take care to rinse off any detergent thoroughly and allow the filters to dry completely before putting them back into the unit Caution Do not dry the filters in direct sunlight or by using a heat...

Страница 6: ... when air cooling operation is stopped Before you ask for repair service check the following points The following symptoms are not air conditioner failures The air blown out from the air conditioner can sometimes give off odors This is due to cigarette smoke contained in the air of the room the smell of cosmetics the walls furniture etc absorbed in the air conditioner A hissing noise can be heard ...

Страница 7: ...ille H inch W inch D inch Net weight Grille Ibs DRY CFM WET CFM Noise level Low Middle2 Middle1 High dB A PLFY Series Fan Airflow rate Low Middle2 Middle1 High PKFY 08NAMU A PKFY 12NGMU A PKFY 20NFMU A PKFY 32NFMU A Single 208 230V 60Hz 8 000 12 000 20 000 32 000 9 000 13 500 22 500 35 500 11 5 8 13 3 8 13 3 8 32 3 32 39 55 1 8 66 1 8 6 7 32 9 1 4 9 1 4 19 35 53 62 170 180 200 210 280 340 370 410 ...

Страница 8: ...phone number on this manual before handing it to the customer This product is designed and intended for use in the residential commercial and light industrial environment HEAD OFFICE MITSUBISHI DENKI BLDG 2 2 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN BG79S714H02 ...

Отзывы: