34
35
35
<How to operate>
To change the airflow direction, press VANE button.
(1) COOL/DRY operation
At the start-up of COOL or DRY operation, the airflow direction in automatically set to 10°. After, it can be changed to
another direction with VANE button on the remote controller.
<Auto return>
When 50° or 60° airflow is set with fan speed on LOW, “1 Hr” appears below the room temperature display. One hour later
the direction changes to 10° degrees, automatically and “1 Hr” disappears.
(2) HEAT operation
At the start-up of HEAT operation, discharge direction depends on the setting of the last operation.
After, it can be changed to another direction with VANE button. The discharge direction shifts to 10° regardless of the
remote controller settings under any of the following conditions.
● Thermostat OFF
● Defrosting
● Indoor fan speed EXTRA-LOW in hot adjustment
Available in COOL operation with fan speed on HIGH or
in HEAT operation.
Unavailable in DRY operation.
If fan speed changes from HIGH to LOW during 30°
downward airflow in COOL mode, the direction auto-
matically changes to 10°.
10°
30°
HEAT•FAN/ COOL•DRY
OPERATION
60°/ 50°
70°/ 60°
Swing
Changes by pressing
the VANE button.
ON/OFF
CHECK
ADDRESS
UNIT No.
FUNCTION No.
SELECTION No.
AM
PM
AM
PM
TEST RUN
FUNCTION
°C
TEMP.
2-5 Auto vane control
OC231A