8
OCH660A
3
PARTS NAMES AND FUNCTIONS
3-1.
Indoor unit
Filter
Air intake
Louver
Air outlet
Vane
[5] Service tools
Use the below service tools as exclusive tools for R32/R410A refrigerant.
No.
Tool name
Specifications
1.
Gauge manifold
· Use the existing fitting specifications. (UNF1/2)
· Use high-tension side pressure of 5.3MPa·G or over.
2.
Charge hose
· Use pressure performance of 5.09MPa·G or over.
3.
Electronic weighing scale
―
4.
Gas leak detector
· Use the detector for R32 or R410A.
5.
Adaptor for reverse flow check
· Attach on vacuum pump.
6.
Refrigerant charge base
―
7.
Refrigerant cylinder
· Top of cylinder (R32 or R410A refrigerant)
· Cylinder with syphon
8.
Refrigerant recovery equipment
―
Electronic weighing scale
Unit