background image

10

GB

D

F

SW

I

NL

E

P

5

D

4
6

When something other than the Auto Off Timer is displayed, set it to AUTO
OFF TIMER using the function selection of remote controller (see Installa-
tion Manual).

2. Hold down the Timer Menu button 

B

 for 

3 seconds

, so that the “Set Up”

appears on the screen (at 

2

).

(Note that each press of the button toggles the display between “Set Up”
and “Monitor”.)

3. Press the appropriate Set Time button 

A

 as necessary to set the OFF time

(at 

3

).

4. Press the Filter 

 button 

4

 to lock in the setting.

Note:
Your entry will be cancelled if you press the Mode (Return) button 

2

2

2

2

2

 before

pressing the Filter 

 button 

4

4

4

4

4

.

5. Press the Mode (Return) button 

2

 to complete the setting procedure and

return to the standard control screen.

6. If the air conditioner is already running, the timer starts countdown immedi-

ately. 

Be sure to check that the timer setting appears correctly on the

display.

s

Checking the Current Auto Off Timer Setting

1. Be sure that the “Auto Off” is visible on the screen (at 

1

).

2. Hold down the Timer Menu button 

B

 for 

3 seconds

, so that “Monitor” is

indicated on the screen (at 

4

).

• The timer remaining to shutdown appears at 

5

.

3. To close the monitor and return to the standard control screen, press the

Mode (Return) button 

2

.

s

To Turn Off the Auto Off Timer...

Hold down the Timer On/Off button 

9

 for 

3 seconds

, so that “Timer Off” ap-

pears (at 

6

) and the timer value (at 

7

) disappears.

Alternatively, turn off the air conditioner itself. The timer value (at 

7

) will disap-

pear from the screen.

s

To Turn On the Auto Off Timer...

Hold down the Timer On/Off button 

9

 for 

3 seconds

. The “Timer Off” indica-

tion disappears (at 

6

), and the timer setting comes on the display (at 

7

).

Alternatively, turn on the air conditioner. The timer value will appear at 

7

.

Using the timer for wireless remote controller (option)

1. Press the 

AUTO STOP

 or 

AUTO START

 button 

4

 (TIMER SET).

Time can be set while the following symbol is blink-
ing.

OFF timer : 

D

 

 is blinking.

ON timer : 

D

 

 is blinking.

2. Use the 

h

 and 

min

 buttons 

5

 to set the de-

sired time.

3. Cancelling the timer.

To cancel the OFF timer, press the 

AUTO STOP

 button 

6

.

To cancel the ON timer, press the 

AUTO START

 button 

6

.

˚C

˚C

AUTO OFF

6

7

AUTO OFF

7

˚C

˚C

AFTER

OFF

AUTO OFF

6

7

AFTER

TIMER

OFF

AUTO OFF

5

1

4

Timer Setting

Examples

If ON and OFF times have both been set at the simple timer, operation and display
are as indicated below.

Example 1:
Start the timer, with ON time set sooner than OFF time
ON Setting:

3 hours

OFF Setting:

7 hours

Example 2:
Start the timer, with OFF time is sooner than ON time
ON Setting:

5 hours

OFF Setting:

2 hours

3.6.3.

Using the Auto Off Timer

This timer begins countdown when the air conditioner starts, and shuts the air
conditioner off when the set time has elapsed.

Available settings run from 30 minutes to 4 hours, in 30-minute intervals.

Note:
*1. Weekly Timer/Simple Timer/Auto Off Timer cannot be used at the same

time.

*2. The Auto Off  timer will not operate when any of the following conditions

is in effect.
The timer is off; the system is in malfunction state; a test run is in progress;
the remote controller is undergoing self-check or remote controller check;
the user is in the process of selecting a function; the user is in the proc-
ess of setting the timer; the system is under central control.  (Under these
conditions, On/Off operation is prohibited.)

s

How to Set the Auto Off Timer

1. Be sure that you are at a standard control screen, and that the Auto Off

timer indicator is visible in the display (at 

1

).

AFTER

OFF

AUTO OFF

PAR-21MAA

ON/OFF 

FILTER

CHECK

OPERATION

CLEAR

TEST

TEMP.

MENU

BACK

DAY

MONITOR/SET

CLOCK

ON/OFF

2

A 9

4

B

AFTER

OFF

AUTO OFF

3

1

2

Timer Setting

ON

Hr

AFTER

SIMPLE

˚C

˚C

OFF

Hr

AFTER

SIMPLE

SIMPLE

At 3 hours after

timer start

At Timer Start

At 7 hours after
timer start

Display shows the tim-
er’s ON setting (hours
remaining to ON).

Display changes to
show the timer’s OFF
setting (hours remain-
ing to OFF). The time
displayed is OFF set-
ting (7 hours) – ON
setting (3 hours) = 4
hours.

The air conditioner
goes off, and will re-
main off until someone
restarts it.

˚C

˚C

OFF

Hr

AFTER

SIMPLE

ON

Hr

AFTER

SIMPLE

˚C

˚C

SIMPLE

At 2 hours after

timer start

At Timer Start

At 5 hours after
timer start

Display shows the tim-
er’s OFF setting
(hours remaining to
OFF).

Display changes to
show the timer’s ON
setting (hours remain-
ing to ON). The time
displayed is ON set-
ting (5 hours) – OFF
setting (2 hours) = 3
hours.

The air conditioner
comes on, and will
continue to run until
someone turns it off.

Содержание PEH-P400

Страница 1: ...trucciones hasta el final antes de poner en marcha la unidad de aire acondicionado para garantizar un uso seguro y correcto ISTRUZIONI DI FUNZIONAMENTO Leggere attentamente questi istruzioni di funzionamento prima di avviare l unità per un uso corretto e sicuro della stessa BEDIENINGSHANDLEIDING Voor een veilig en juist gebruik moet u deze bedieningshandleiding grondig doorlezen voordat u de airco...

Страница 2: ...P AUTO START h min LOUVER MODE CHECK RESET SET CLOCK 5 A 2 Fig 2 0 1 A Air outlet B Air inlet C Air filter Fig 2 0 2 A Wireless remote controller option B Remote controller Fig 3 0 1 ON OFF TEMP B 1 2 3 4 6 5 A B D C Fig 5 0 1 A Air outlet C Air filter B Air inlet D Air filter handle 3 A B C ...

Страница 3: ...ided Indicates that important instructions must be followed Indicates a part which must be grounded Indicates that caution should be taken with rotating parts This symbol is displayed on the main unit label Color yellow Beware of electric shock This symbol is displayed on the main unit label Color yellow Warning Carefully read the labels affixed to the main unit 1 1 Installation s After you have r...

Страница 4: ...detect odd smells stop using the unit turn off the power switch and consult your dealer Otherwise a breakdown electric shock or fire may result When you notice exceptionally abnormal noise or vibration stop opera tion turn off the power switch and contact your dealer Do not over cool The most suitable inside temperature is one that is within 5 C of the outside temperature Do not leave handicapped ...

Страница 5: ...eless remote controller option Replacing the Batteries and how to set the current time Fig 3 0 1 P 2 If no signal is transmitted and the indoor unit s lamp does not light up even if the remote controller is operated the batteries may have run out so replace them with new ones as described below 1 Remove the front lid 2 Replace the batteries with alkali batteries size AAA Make sure that the bat ter...

Страница 6: ... current time unless the simple or Auto Off timer is set If the simple or Auto Off timer is set shows the time remaining B Sensor indication Displayed when the remote controller sensor is used C Identifies the current operation Shows the operating mode etc Multilanguage display is supported D Centrally Controlled indicator Indicates that operation of the remote controller has been prohibited by a ...

Страница 7: ...of your choice The compressor and indoor fan function is linked motion according to the change of the room temperature and automatically repeat ON OFF 2 When reaching room temperature of your choice Both the compressor and indoor fan stop When stop continues for 10 minutes the compressor and indoor fan are oper ated for 3 minutes to keep the humidity low For heating Press the 2 2 2 2 2 operation m...

Страница 8: ...ay Saturday 8 30 ON 23 C 10 00 OFF 10 00 OFF 10 00 OFF 10 00 OFF Operation 1 settings for Sunday Start the air conditioner at 8 30 with the tem perature set to 23 C Operation 2 settings for every day Turn off the air condi tioner at 10 00 No 1 No 2 No 8 s How to Set the Day of the Week and Time 1 Press the or Set Time button A to show display 2 2 Press the Timer On Off Set Day button 9 to set the ...

Страница 9: ...t the Set Up appears on the screen at 2 Note that each press of the button toggles the display between Set Up and Monitor 3 Press the ON OFF button 1 to display the current ON or OFF simple timer setting Press the button once to display the time remaining to ON and then again to display the time remaining to OFF The ON OFF indication appears at 3 ON timer The air conditioner will start operation w...

Страница 10: ...he AUTO START button 6 C C AUTO OFF 6 7 AUTO OFF 7 C C AFTER OFF AUTO OFF 6 7 AFTER TIMER OFF AUTO OFF 5 1 4 Timer Setting Examples If ON and OFF times have both been set at the simple timer operation and display are as indicated below Example 1 Start the timer with ON time set sooner than OFF time ON Setting 3 hours OFF Setting 7 hours Example 2 Start the timer with OFF time is sooner than ON tim...

Страница 11: ...NCTION 1 C C TIME SUN FUNCTION PAR 21MAA ON OFF FILTER CHECK OPERATION CLEAR TEST TEMP MENU BACK DAY MONITOR SET CLOCK ON OFF 4 1 1 Lock Indicator ON OFF TEMP C C ON OFF TEMP C C FILTER ON OFF C C ERROR CODE Error Code 3 8 2 Flashing Mode Indicator When flashes continuously Displayed when another indoor unit connected to the outdoor unit is already operating in a different operation mode Match wit...

Страница 12: ...away lightly or clean it up with a vacuum cleaner In the case of severe staining wash the filter in lukewarm water mixed with dissolved neutral detergent or water and then rinse off the detergent completely After washing dry it and fix it back into place Caution Do not dry the filter by exposing it to direct sunlight or warming it using fire etc Doing so can result in the deformation of the filter...

Страница 13: ...in the remote controller An automatic startup test is being performed will last for about two minutes An error code is displayed in the remote controller A self diagnostic function is being performed to preserve the air conditioner Do not attempt to make repairs yourself Turn the main switch off and contact the dealer from whom you bought the air conditioner Provide him or her with the name of the...

Страница 14: ...s of installa tion sites For further details consult with your dealer Regarding electrical work Caution The electrical work must be undertaken by a person who is qualified as an electric engineer according to the technical standard respecting elec trical installation internal wiring rules and the installation instruction manual with the absolute use of exclusive circuits The use of other prod ucts...

Страница 15: ...r The product at hand is based on the following EU regulations Low Voltage Directive 73 23 EEC Electromagnetic Compatibility Directive 89 336 EEC This product is designed and intended for use in the residential commer cial and light industrial environment HEAD OFFICE MITSUBISHI DENKI BLDG 2 2 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN ...

Страница 16: ......

Отзывы: