18
PEA-RP400,500GAQ
FUSE
FUSE
t˚
t˚
t˚
t˚
t˚
t˚
DSR
U
U
U
DSA
GREEN/YELLO
W
(*1)SW2
12
2
1
4
3
OFF
ON
5
ON
OFF
SW1
5
4
3
ON
OFF
SWE
12
2
1
4
3
OFF
ON
5
ON
OFF
SW1
5
4
3
ON
OFF
SWE
49F
X02
X01
4
5
C01
52F
3
2
1
3
2
1
C02
C01
52F
L1
L2
L3
TB2
RED
WHITE
BLA
CK
N
RED
WHITE
BLACK
BLUE
51F
FB22
FB12
TB4-1
TB4-2
TH1-2
TH2-2
TH5-2
TH5-1
TH2-1
TH1-1
X2
S3
S2
S1
FB21
X1
TB5
S3
S2
2
1
S1
FB11
1
2
2
1
2
1
4
3
2
1
CN29
CN41
CN21
CN20
CN3C
2
1
3
3
1
2
1
2
1
2
LED3
LED2
LED1
X6
X5
X4
3
75
1
DC13.1V
21
1
3
1
3
1
3
ZNR
54321
CN51
CN31
CN32
CND
CNDK
FA
N
CN2L
CN22
CN2D
DC
13.1V
CN2S
1
2
CNSK
1
3
DC
13.1V
CN2S
1
2
CNSK
1
3
CN3C
2
1
3
3
1
2
1
2
1
2
LED3
LED2
LED1
DC13.1V
21
1
3
1
3
ZNR
54321
CN51
CN31
CN32
CND
CN2L
CN22
CN2D
1
2
2
1
2
1
4
3
2
1
CN29
CN41
CN21
CN20
X6
X5
X4
3
75
1
1
3
CNDK
FA
N
TAB1
TAB1
(*1)SW2
PO
WER BO
ARD
INDOOR
SNB BO
ARD 1
(No
.2)
CONTR
OLLER BO
ARD
INDOOR
INDOOR
PO
WER BO
ARD
CONTR
OLLER BO
ARD
51F
CR
ZNR5~7
12
4
3
OFF
ON
5
(*1)SW2
(No
.1)
(No
.2)
(No
.1)
INDOOR
Note:1.
Color of ear
th wire is y
ello
w and g
reen twisting.
2.
Specification subject to change without notice
.
3.
Indoor and outdoor connecting wires are made with polar
ities
,mak
e sure
matching wir
ing and ter
minal.
4.
Emergency oper
ation
If a troub
le occurs with either the remote controller or the indoor
microcomputer and no other troub
le e
xists
, emergency oper
ation f
or
cooling or heating
can be perf
or
med b
y changing the setting of connector (SWE) "ON" on the
indoor controller board.
SWE :ON / Indoor f
an is r
unning high speed.
5.
Symbols used in wir
ing diag
ram abo
ve are
,
:CONNECT
OR
:TERMINAL
(HEA
VY DO
TTED LINE):FIELD
WIRING
(THIN DO
TTED LINE) :OPTIONAL P
AR
TS
6.
(*1)SW2 sho
ws PEA-RP500 setting.(2places)
In case of PEA-RP400 setting is sho
wn as belo
w
.
M
1~
INDOOR UNIT
TB6
REMO
TE CONTR
OLLER
2
1
BO
ARD
REMO
TE CONTR
OLLER
PE
CIRCUIT BREAKER
(FIELD SUPPL
Y)
PEA-RP400,500GA
Q:15A
PO
WER SUPPL
Y
3N~PE
380/400/415V
50Hz
OUTDOOR UNIT
OUTDOOR UNIT
TO
OUTDOOR UNIT
CONNECTING WIRES
(POLAR)
TO
OUTDOOR UNIT
CONNECTING WIRES
(POLAR)
(No
.1)
(No
.2)
CONNECT
OR (LOSSNA
Y)
CONNECT
OR (CENTRALL
Y CONTR
OL)
CONNECT
OR (HA
TERMINAL-A)
CONNECT
OR (REMO
TE SWITCH)
CONNECT
OR (DRAIN SENSOR)
CN32
CN41
CN51
CN31
CN2L
TB3,TB8
SYMBOL
NAME
TERMINAL BLOCK
OUTDOOR UNIT
CONNECT
OR (EMERGENCY OPERA
TION)
SWITCH (CAP
A
CITY CORD)
SW1
SWITCH (MODEL SELECTION)
LED (TRANSMISSION<INDOOR·OUTDOOR>)
LED3
LED (PO
WER SUPPL
Y<REMO
TE CONTR
OLLER>)
LED2
LED (PO
WER SUPPL
Y)
LED1
SWE
SW2
ARRESTER
DSA,DSR
V
ARIST
OR
ZNR5~7
SNB BO
ARD 1
SYMBOL
NAME
A
UXILIAR
Y RELA
Y
X1,2
INDOOR
CONTR
OLLER
BO
ARD
FB21,FB22
FB11,FB12
FERRITE CORE
COND/EV
A TEMP
LIQ
UID PIPE
TEMP
R
OOM TEMP
52F
MA
GNETIC CONT
A
CT
OR (INDOOR F
AN MO
T
OR)
SURGE KILLER
CR
TH5-1,5-2
V
ARIST
OR
ZNR
FUSE (T6.3AL250V)
FUSE
INDOOR UNIT
THERMIST
OR
TERMINAL BLOCK
INTERNAL
THERMOST
A
T (INDOOR F
AN MO
T
OR)
O
VER CURRENT RELA
Y (INDOOR F
AN MO
T
OR)
F
AN MO
T
OR (INDOOR)
TH2-1,2-2
TH1-1,1-2
TB2,4-1,4-2,5
49F
51F
MF1
X4-6
A
UXILIAR
Y RELA
Y
NAME
REMO
TE CONTR
OLLER
SYMBOL
TB6
TERMINAL BLOCK
Caution,
1.
T
o protect f
an motor from abnor
mal current,o
ver current rela
ys is installed.
Theref
ore
, do not change f
actor
y set v
alue of o
ver current rela
ys
.
U
U
HWE1007B.qx 6/2/15 4:27 PM Page 18