Wireless Remote-Controller (option)

2. Parts Names

■ 

When using the wireless remote controller, point it towards the receiver on the indoor unit.

 If the remote controller is operated within approximately two minutes after power is 

supplied to the indoor unit, the indoor unit may beep twice as the unit is performing the 

initial automatic check.

 The indoor unit beeps to confirm that the signal transmitted from the remote controller has 

been received. Signals can be received up to approximately 7 meters in a direct line from 

the indoor unit in an area 45° to the left and right of the unit. However, illumination such 

as fluorescent lights and strong light can affect the ability of the indoor unit to receive 

signals.

 If the operation lamp near the receiver on the indoor unit is flashing, the unit needs to be 

inspected. Consult your dealer for service.

 Handle the remote controller carefully! Do not drop the remote controller or subject it to 

strong shocks. In addition, do not get the remote controller wet or leave it in a location 
with high humidity.

 To avoid misplacing the remote controller, install the holder included with the remote 

controller on a wall and be sure to always place the remote controller in the holder after 

use.

Battery installation/replacement 

1. Remove the top cover, insert two AAA 

batteries, and then install the top cover.

Top cover

Two AAA batteries
Insert the negative 

(–) end of each 

battery first. Install the 

batteries in the correct 
directions (+, –)!

2. Press the Reset button.

CLOCK

CHECK

RESET

SET

TEST RUN

MODE

FAN

VANE

LOUVER

min

h

AUTO START

AUTO STOP

ON/OFF

TEMP

NOT AVAILABLE

MODEL SELECT

TEST RUN

CHECK

ON/OFF button

Pushing button starts operation. 
Pushing again stops operation. 

MODE SELECT button

This button is used to change 
between auto, cooling, heating 
and drying operation modes.

SET TEMPERATURE button

SET TEMPERATURE button 
sets and any desired room 
temperature.

AUTO STOP/AUTO START button

Used for selecting timed starting 

or stopping. 

h button

Used for setting the current time.

VANE CONTROL button

Used to change the airflow 

direction.

FAN SPEED button

This button is used to set fan 

speed to low, medium or high.

CHECK button

TEST RUN button

min button

Used for setting the current time.

LOUVER button

Used for adjusting the airflow 

direction.

Press the Reset 

button with an object 

that has a narrow end.

Содержание PEA-RP200WKA

Страница 1: ...ditioner gebruikt VOOR DE GEBRUIKER Svenska DRIFTSMANUAL Läs denna driftsmanual noga för säkert och korrekt bruk innan luftkonditioneringen används FÖR ANVÄNDAREN Dansk DRIFTSMANUAL Læs venligst denne driftsmanual grundigt før airconditionanlægget betjenes af hensyn til sikker og korrekt brug TIL BRUGER Português MANUAL DE OPERAÇÃO Para segurança e utilização correctas leia atentamente o manual de...

Страница 2: ...dicated in the manuals provided with the unit and on the nameplate Doing so may cause the unit or pipes to burst or result in explosion or fire during use during repair or at the time of disposal of the unit It may also be in violation of applicable laws MITSUBISHI ELECTRIC CORPORATION cannot be held responsible for malfunctions or accidents resulting from the use of the wrong type of refrigerant ...

Страница 3: ... on the screen When the backlight is off pressing any button turns the backlight on and does not perform its function except for the ON OFF button ON OFF lamp This lamp lights up in green while the unit is in operation It blinks while the remote controller is starting up or when there is an error Function button F1 Main display Press to change the operation mode Main menu Press to move the cursor ...

Страница 4: ...hen the buttons are locked Full mode All icons are displayed for explanation Basic mode Fri Mode Temp Fan Room Cool Set temp Fri Cool Mode Temp Fan Set temp Appears when the On Off timer Night setback or Auto off timer function is enabled appears when the timer is disabled by the centralized control system Appears when the Weekly timer is enabled Appears while the units are operated in the energy ...

Страница 5: ...acing the remote controller install the holder included with the remote controller on a wall and be sure to always place the remote controller in the holder after use Battery installation replacement 1 Remove the top cover insert two AAA batteries and then install the top cover Top cover Two AAA batteries Insert the negative end of each battery first Install the batteries in the correct directions...

Страница 6: ...peration modes in the order of Cool Dry Fan Auto and Heat Select the desired operation mode Cool Dry Fan Auto Heat Operation modes that are not available to the connected indoor unit models will not appear on the display What the blinking mode icon means The mode icon will blink when other indoor units in the same refrigerant system connected to the same outdoor unit are already operated in a diff...

Страница 7: ...ion state in flashing In this case please set all the indoor units to the same operation mode There might be a case that the indoor unit which is operating in AUTO mode Cannot change over to the operating mode COOL HEAT and becomes a state of standby When indoor unit starts the operation while the defrosting of outdoor unit is being done it takes a few minutes max about 15 minutes to blow out the ...

Страница 8: ...display If no buttons are touched for 10 minutes the screen will automatically return to the Main display Any settings that have not been saved will be lost Display of unsupported functions F1 F2 F3 F4 Title Not available Unsupported function Return The message at left will appear if the user selects a function not supported by the corresponding indoor unit model 3 5 2 Vane Vent Lossnay Accessing ...

Страница 9: ... HEAT button selects the following settings Operation mode COOL HEAT Preset temperature 24 C 75 F 24 C 75 F Fan speed High High 1 Set the current time Press the CLOCK button using a thin stick and blink the time Ⓐ Press the h and min button to set the current time Press the CLOCK button using a thin stick 2 Set the time to start the unit as follows Press the AUTOSTART button Time can be set while ...

Страница 10: ... water may form and drip from the heat exchanger During defrosting mode water on the heat exchanger evaporates and water vapor may be emitted appears in the remote controller display During central control appears in the remote controller display and air conditioner operation cannot be started or stopped using the remote controller When restarting the air conditioner soon after stopping it it does...

Страница 11: ... batteries are replaced make sure that the batteries are installed in the correct directions The operation lamp near the receiver for the wireless remote controller on the indoor unit is flashing The self diagnosis function has operated to protect the air conditioner Do not attempt to repair this equipment by yourself Turn off the power switch immediately and consult your dealer Be sure to provide...

Страница 12: ...и ООО Мицубиси Электрик РУС Адрес Россия 115054 Москва Космодамианская наб д 52 стр 1 HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN This product is designed and intended for use in the residential commercial and light industrial environment The product at hand is based on the following EU regulations Low Voltage Directive 2014 35 EU Electromagnetic Compatibility Directive...