background image

17

PEA-RP400,500GA

GREEN/YELLOW

INDOOR UNIT

OUTDOOR UNIT

OUTDOOR UNIT

TAB1

TAB1

FAN

CNDK

31

1

5

73

X4

X5

X6

CN20

CN21

CN41

CN29

1

2

3

4

1

2

1

2

2

1

CN2D

CN90

CN22

CN2L

CND

CN32

CN31

CN51

1
2
3
4
5

FUSE

ZNR

31

31

1
2

DC13.1V

LED1

LED2

LED3

2

1

2

1

2

1

2

1

3

3

6

5

4

9

8

7

3

1

2

CN3C

3

1

CNSK

2

1

CN2S

DC

13.1V

3

1

CNSK

2

1

CN2S

DC

13.1V

CN2D

CN90

CN22

CN2L

FAN

CNDK

CND

CN32

CN31

CN51

1
2
3
4
5

FUSE

ZNR

31

31

31

1
2

DC13.1V

1

5

73

X4

X5

X6

LED1

LED2

LED3

2

1

2

1

2

1

2

1

3

3

6

5

4

9

8

7

3

1

2

CN3C

CN20

CN21

CN41

CN29

1

2

3

4

1

2

1

2

2

1

FB11

S1

1

2

REMOTE CONTROLLER

S2

S3

TB5

TB6

LCD

X1

FB21

S1

S2

S3

X2

TH1-1

TH2-1

TH5-1

TH5-2

TH2-2

TH1-2

TB4-2

TB4-1

FB12

FB22

X4

X5

X6

X4

X5

X6

51F

BLUE

POWER SUPPLY

3N~PE

380/400/415V

50Hz

CIRCUIT BREAKER

(FIELD SUPPLY)

PEA-RP400,500GA:15A

BLACK

WHITE

RED

DSR

DSA

N

BLACK

WHITE

RED

TB2

L3

L2

L1

PE

52F

C01

C02

1

2

3

MF1

1

2

3

52F

C01

5

4

X01

X02

49F

SWE

OFF

ON

345

SW1

OFF

ON

5

ON

OFF

34

12

2
1

SWE

OFF

ON

345

SW1

OFF

ON

5

ON

OFF

SW2

34

12

2
1

SW2

AUXILIARY RELAY

X4-6

MF1

51F

49F

TB2,4-1,4-2,5

TH1-1,1-2

TH2-1,2-2

FAN MOTOR (INDOOR)

OVER CURRENT RELAY (INDOOR FAN MOTOR)

INTERNAL THERMOSTAT (INDOOR FAN MOTOR)

TERMINAL BLOCK

THERMISTOR

INDOOR UNIT

FUSE

FUSE (T6.3AL250V)

ZNR

VARISTOR

TH5-1,5-2

CR

SURGE KILLER

MAGNETIC CONTACTOR (INDOOR FAN MOTOR)

52F

ROOM TEMP

LIQUID PIPE TEMP

COND/EVA TEMP 

FERRITE CORE

FB11,FB12

FB21,FB22

INDOOR

CONTROLLER

BOARD

X1,2

AUXILIARY RELAY

NAME

SYMBOL

SNB

BOARD 1

ZNR5~7

VARISTOR

DSA,DSR

ARRESTER

SW2

SWE

LED1

LED (POWER SUPPLY)

LED2

LED (POWER SUPPLY<REMOTE CONTROLLER>)

LED3

LED (TRANSMISSION<INDOOR

·

OUTDOOR>)

SWITCH (MODEL SELECTION)

SW1

SWITCH (CAPACITY CORD)

CONNECTOR (EMERGENCY OPERATION)

OUTDOOR UNIT

TERMINAL BLOCK

NAME

SYMBOL

TB3,TB8

CN2L

CN31

CN90

CN51

CN41

CN32

CONNECTOR (DRAIN SENSOR)

CONNECTOR (REMOTE SWITCH)

CONNECTOR (HA TERMINAL-A)

CONNECTOR (CENTRALLY CONTROL)

CONNECTOR (WIRELESS REMOTE CONTROLLER)

CONNECTOR (LOSSNAY)

REMOTE CONTROLLER

TERMINAL BLOCK

NAME

SYMBOL

TB6

4.Indoor and outdoor connecting wires are made with polarities,make sure

matching wiring and terminal.

5.Emergency operation

    If a trouble occurs with either the remote controller or the indoor microcom-

    puter and no other trouble exists, emergency operation for cooling or heating

    can be performed by changing the setting of connector (SWE) "ON" on the

    indoor controller board.

    SWE  :ON / Indoor fan is running high speed.

(No.2)

INDOOR

CONTROLLER

 BOARD

(No.1)

REMOTE CONTROLLER BOARD

INDOOR POWER BOARD

(No.1)

(No.2)

INDOOR

CONTROLLER

BOARD

(No.2)

TO OUTDOOR UNIT

CONNECTING WIRES

 (POLAR)

TO OUTDOOR UNIT

CONNECTING WIRES

 (POLAR)

SNB BOARD 1

(No.1)

INDOOR POWER BOARD

Note:1.The dotted lines show field wiring.

2.Color of earth wire is yellow and green twisting.

3.Specification subject to change without notice.

51F

6.   mark is connector.   mark is terminal.

Caution,

1.To protect fan motor from abnormal current,over current relays is installed.

  Therefore, do not change factory set value of over current relays.

CR

ZNR5~7

Содержание PEA-RP200GA

Страница 1: ...GA CONTENTS 1 TYPES OF CONNECTED OUTDOOR UNITS 2 2 SAFETY PRECAUTION 3 3 PART NAMES AND FUNCTIONS 8 4 SPECIFICATIONS 10 5 DATA 11 6 OUTLINES AND DIMENSIONS 13 7 WIRING DIAGRAM 16 8 REFRIGERANT SYSTEM DIAGRAM 18 9 TROUBLESHOOTING 19 10 SERVICE DATA PARTS NAME 30 Indoor unit Remote controller SPLIT TYPE HEAT PUMP AIR CONDITIONERS 2007 ...

Страница 2: ... P200YHA PUHZ RP200YHA2 PUHZ P250YHA PUHZ RP250YHA2 PUHZ P200YHA x 2 PUHZ RP200YHA2 x 2 PUHZ P250YHA x 2 PUHZ RP250YHA2 x 2 Standard Model Steel fan PEA RP200GA PEA RP250GA PEA RP400GA PEA RP500GA PEA RP200GA TH AF PEA RP250GA TH AF PEA RP400GA TH AF PEA RP500GA TH AF PEA RP200GA TH AFMF PEA RP250GA TH AFMF Model name Specification ...

Страница 3: ...can cause deterioration of refrigerant oil etc Use the following tools specifically designed for use with R410A refrigerant The following tools are necessary to use R410A refrigerant Keep the tools with care If dirt dust or moisture enter into refrigerant cycle that can cause deterioration of refrigerant oil or malfunction of com pressor Do not use a charging cylinder If a charging cylinder is use...

Страница 4: ...ends of the pipes should be sealed until immediately before brazing Wrap elbows and T s in plastic bags for storage The new refrigerator oil is 10 times more hygroscopic than the conventional refrigerator oil such as Suniso Water infiltration in the refrigerant circuit may deteriorate the oil or cause a compressor failure Piping materials must be stored with more care than with the conventional re...

Страница 5: ...o flux when brazing between copper pipes or between a copper pipe and copper coupling 4 If installed refrigerant pipes are not immediately connected to the equipment then braze and seal both ends of them Reasons 1 The new refrigerant oil is 10 times more hygroscopic than the conventional oil The probability of a machine failure if water infiltrates is higher than with conventional refrigerant oil ...

Страница 6: ...frigerant circuit when the vacuum pump power is turned off power failure It is also possible to attach a check valve to the actual vacuum pump afterwards 2 Standard degree of vacuum for the vacuum pump Use a pump which reaches 0 5 Torr 500 MICRON or below after 5 minutes of operation In addition be sure to use a vacuum pump that has been properly maintained and oiled using the specified oil If the...

Страница 7: ...rigerant No Specifications 1 Gauge manifold Only for R410A Use the existing fitting specifications UNF1 2 Use high tension side pressure of 5 3MPa G or over 2 Charge hose Only for R410A Use pressure performance of 5 09MPa G or over 3 Electronic scale 4 Gas leak detector Use the detector for R134a R407C or R410A 5 Adaptor for reverse flow check Attach on vacuum pump 6 Refrigerant charge base 7 Refr...

Страница 8: ...into the unit PAR 21MAA ON OFF FILTER CHECK OPERATION CLEAR TEST TEMP MENU BACK DAY MONITOR SET CLOCK ON OFF Set Temperature buttons Down Up Timer Menu button Monitor Set button Mode button Return button Set Time buttons Back Ahead Timer On Off button Set Day button Opening the door ON OFF button Fan Speed button Filter button Enter button Test Run button Check button Clear button Airflow Up Down ...

Страница 9: ...ponding timer is set Up Down Air Direction indica tor The indicator shows the direc tion of the outcoming airflow One Hour Only indicator Displayed if the airflow is set to weak and downward during COOL or DRY mode Operation varies according to model The indicator goes off after one hour at which time the airflow di rection also changes Room Temperature display Shows the room temperature Louver di...

Страница 10: ...stat Sound level Drain connection Dimensions Weight Mode Fan drive o No Fan motor output Airflow External static pressure Hi Lo Model name Cooling 1 55 3 8 Heating 1 55 3 8 H W D kW A CMM L s Pa mmAq dB A mm mm mm kg lbs PEA RP400GA PEA RP500GA 3PH 4W 50Hz 380 415V Galvanized steel Cross fin coil Centrifugal direct o2 1 3 120 2 000 150 15 Remote control built in 52 R1 595 1947 764 130 286 Cooling ...

Страница 11: ...0 250 Upper High Lower Low SPL dB A 63Hz 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz 8000Hz 51 55 54 51 49 47 43 33 27 48 50 50 47 46 44 40 29 21 52 56 55 52 50 48 44 34 28 49 51 51 48 47 45 41 30 22 53 55 54 51 50 48 44 40 31 OCTAVE BAND FREQ Hz Model 52 53 51 52 50 46 44 39 30 PEA RP200GA PEA RP250GA PEA RP500GA PEA RP400GA ...

Страница 12: ...0 110 0 120 0 130 0 90 0 Pa Pa Pa External static pressure Air flow CMM 0 50 100 150 200 300 250 110 0 100 0 120 0 130 0 140 0 150 0 160 0 170 0 Pa External static pressure Air flow CMM 0 50 100 150 200 350 300 250 Hi Lo 45 0 50 0 55 0 60 0 65 0 70 0 Hi Lo 0 50 100 150 200 250 300 0 50 100 150 200 250 60 0 65 0 70 0 75 0 80 0 85 0 90 0 External static pressure Air flow Air flow CMM CMM External st...

Страница 13: ... ø3 Holes Refrigerant pipe ø9 52 3 8 braze Refrigerant pipe ø25 4 1 braze Accessory 2pcs Pipe cover For dew condensation prevention of local piping and unit connection 1pc Remote controller Return air Left side view Supply air Front view 75 55 129 70 42 124 34 131 530 50 95 250 11 7x130 910 10 130 130 45 45 31 31 1102 200 10 8x130 1040 1300 20 199 100 40 20 462 144 1284 400 155 1000 105 40 1260 40...

Страница 14: ...eft side view Supply air Return air Front view Return air sensor Accessory Pipe cover 2pcs For dew condensation prevention of local piping and unit connection Remote controller 1pc Refrigerant pipe ø12 7 1 2 braze Refrigerant pipe ø25 4 1 braze 42 144 145 75 55 70 129 124 131 50 530 34 130 95 250 11 10 66 1302 1484 7x130 910 130 45 45 200 20 100 20 199 40 1500 462 66 9X130 1170 10 25 100 100 25 10...

Страница 15: ...t flange Control box Supply air duct flange A Rubber bush Remote controller wiring Rubber bush Power supply wiring Rubber bush Outdoor unit connection wiring A Accessory Pipe cover 4pcs For dew condensation prevention of local piping and unit connection Remote controller 1pc 81 117 156 117 10 20 1840 10 40 60 60 61 60 40 40 1800 1880 50 664 525 22 102 22 5 120 4X120 480 22 5 595 1824 50 764 280 11...

Страница 16: ...OSTAT INDOOR FAN MOTOR OVER CURRENT RELAY INDOOR FAN MOTOR FAN MOTOR INDOOR TH2 TH1 TB2 4 5 49F 51F MF1 52FLo MAGNETIC CONTACTOR INDOOR FAN MOTOR LOW SPEED AUXILIARY RELAY X1 FERRITE CORE FB BOARD CONTROLLER INDOOR CN2L CN31 CN90 CN51 CN41 CN32 CONNECTOR DRAIN SENSOR CONNECTOR REMOTE SWITCH CONNECTOR HA TERMINAL A CONNECTOR CENTRALLY CONTROL CONNECTOR WIRELESS REMOTE CONTROLLER CONNECTOR LOSSNAY 4...

Страница 17: ...FB21 FB22 INDOOR CONTROLLER BOARD X1 2 AUXILIARY RELAY NAME SYMBOL SNB BOARD 1 ZNR5 7 VARISTOR DSA DSR ARRESTER SW2 SWE LED1 LED POWER SUPPLY LED2 LED POWER SUPPLY REMOTE CONTROLLER LED3 LED TRANSMISSION INDOOR OUTDOOR SWITCH MODEL SELECTION SW1 SWITCH CAPACITY CORD CONNECTOR EMERGENCY OPERATION OUTDOOR UNIT TERMINAL BLOCK NAME SYMBOL TB3 TB8 CN2L CN31 CN90 CN51 CN41 CN32 CONNECTOR DRAIN SENSOR CO...

Страница 18: ...TH2 Distributor Condenser evaporator temperature thermistor TH5 Room temperature thermistor TH1 Refrigerant flow in cooling Refrigerant flow in heating Strainer Strainer Heat exchanger Refrigerant GAS pipe connection Brazing Refrigerant LIQUID pipe connection Brazing 8 REFRIGERANT SYSTEM DIAGRAM ...

Страница 19: ...ve action according to TROUBLESHOOTING BY INFERIOR PHENOMENA 9 3 The inferior phenomenon is not reoccurring Logged Not logged 1Consider the temporary defects such as the work of protection devices in the refrigerant circuit including compressor poor connection of wiring noise and etc Re check the symptom and check the installation environment refrigerant amount weather when the inferior phenomenon...

Страница 20: ...rature with remote controller in test run mode If pipe liquid temperature is exclusively low in cooling mode or high in heating mode refrigerant circuit may have defective 5 Check pipe liquid temperature with remote controller in test run mode If there is exclusive difference with actual pipe liquid temperature replace indoor controller board Turn the power off and on again to operate after check ...

Страница 21: ...s defective Indoor controller board is defective 5 Defective outdoor fan control 6 Overcharge of refrigerant 7 Defective refrigerant circuit clogs 8 Bypass circuit of outdoor unit is defective Cooling or drying mode 1 Check clogs of the filter 2 Remove shields 4 Measure the resistance of fan motor s winding Measure the output voltage of fan s connector Relay for FAN on the indoor controller board ...

Страница 22: ...ndoor units max 16units The number of connecting remote con troller max 2units When it is not the above mentioned problem of 1 3 4 Diagnose remote controllers a When RC OK is displayed Remote controllers have no problem Put the power off and on again to check If abnormality generates again replace indoor controller board b When RC NG is displayed Replace remote controller c When RC E3 is displayed...

Страница 23: ... Defective transmitting receiving circuit of indoor controller board 3 Defective transmitting receiving circuit of indoor controller board 4 Noise has entered into indoor outdoor unit connecting wire Check LED display on the outdoor control cir cuit board Connect A control service tool PAC SK52ST Refer to EA EC item if LED displays EA EC 1 Check disconnection or looseness of indoor outdoor unit co...

Страница 24: ...between indoor controller board and indoor power board Check the fuse on indoor controller board If no problems are found indoor controller board is defective When LED1 on indoor controller board is lit 1 Mis setting of refrigerant address for outdoor unit There is no unit corresponding to refrigerant address 0 1 Reconfirm the setting of refrigerant address for outdoor unit Set the refrigerant add...

Страница 25: ...ontroller wires again and if LED2 is blinking remote controller is defective if LED2 is lit connection failure of remote controller terminal block etc has returned to normal 9 4 WHEN WIRED REMOTE CONTROLLER OR INDOOR UNIT MICRO COMPUTER TROUBLES 1 If there is not any other wrong when trouble occurs emergency operation starts as the indoor controller board switch SWE is set to ON During the emergen...

Страница 26: ...A Red White White Blue Red Blue Red White White Blue Red Blue Red White White Blue Red Blue Red White White Blue Red Blue Abnormal Open or short Hi Lo 34 2Ω PEA RP 400GA 25 2Ω PEA RP 500GA Measure the resistance value across the terminals with a multimeter Winding temperature 20 C LO LO HI HI U2 U1 V1 V1 W1 W2 LO HI Black marking Black marking Black marking Yellow Blue Red Red Blue Yellow White Wh...

Страница 27: ... 1 Power board PEA RP200GA PEA RP250GA PEA RP400GA PEA RP500GA CNSK Connect to the indoor controller board CNDK Between 1 1 to 3 3 220 240V AC CN2S Connect to the indoor controller board CN2D Between 1 1 to 3 3 12 6 13 7V DC Pin1 1 ...

Страница 28: ...L Connector LOSSNAY CN51 Centrally control CN6V Vane motor output MV CN90 Connect to the wireless remote controller board CNB CN31 Drain sensor DS CN29 Condenser evaporator temperature thermistor TH5 CN21 Pipe temperature thermistor Liquid TH2 CN20 Room temperature thermistor TH1 CN22 Remote controller connecting wire 10 4 14 6V DC LED3 Transmission Indoor outdoor LED2 Power supply R B LED1 Power ...

Страница 29: ... these models have the cond eva temperature thermistor TH5 Marks in the table below Jumper wire Short Open Without TH5 With TH5 Model JP1 Factory shipment Service parts Indoor controller board type JP3 PEA RP200 250 PEA RP400 500 1 OFF ON 5 4 3 2 1 OFF ON 5 4 3 2 1 OFF ON 5 4 3 2 9 7 FUNCTIONS OF DIP SWITCH AND JUMPER WIRE Each function is controlled by the dip switch and the jumper wire on contro...

Страница 30: ...rain pan Drain pipe connection R1 Fan motor Sirocco fan Suspension bracket Special washer Liquid pipe thermistor TH2 2 phase pipe thermistor TH5 Strainer Strainer Heat exchanger Liquid pipe Gas pipe Inlet thermistor TH1 Drain pan PEA RP200 250GA ...

Страница 31: ...an Liquid pipe thermistor TH2 1 Liquid pipe thermistor TH2 2 Strainer No 2 Strainer Strainer No 1 Strainer 2 phase pipe thermistor TH5 1 Heat exchanger No 1 Liquid pipe No 1 Gas pipe No 2 Liquid pipe 2 phase pipe thermistor TH5 2 No 2 Gas pipe No 2 Inlet thermistor TH1 2 No 1 Inlet thermistor TH1 1 PEA RP400 500GA ...

Страница 32: ...F Hi 52F 51F X1 FB view A L2 N L3 L1 TB2 TB4 TB5 1 2 S2 S1 S3 Relay SNB board Magnetic contactor Fan motor Lo speed Magnetic contactor Fan motor Hi speed Terminal block for remote controller Terminal block for outdoor indoor control wiring connection Power supply terminal block PEA RP200 250GA ...

Страница 33: ...core Ferrite core Control board No 2 unit Control board No 1 unit Relay Power supply terminal block Terminal block for outdoor indoor control wiring connection No 1 unit Terminal block for outdoor indoor control wiring connection No 2 unit Terminal block for remote controller Magnetic contactor Control board No 1 unit Control board No 2 unit SNB board PEA RP400 500GA ...

Страница 34: ...New publication effective Nov 2007 Specifications subject to change without notice HWE0708B Printed in Japan ...

Отзывы: