Mitsubishi Electric PEA-RP200 GA Скачать руководство пользователя страница 5

5

GB

D

F

I

NL

E

SW

P

PAR-21MAA

ON/OFF 

FILTER

CHECK

OPERATION

CLEAR

TEST

TEMP.

MENU

BACK

DAY

MONITOR/SET

CLOCK

ON/OFF

1

4

5

67

8

9

0

A

B

C

2

3

˚F˚C

˚F˚C

ERROR CODE

AFTER

TIMER

TIME SUN MON TUE WED THU FRI SAT

ON

OFF

Hr

AFTER

FILTER

FUNCTION

ONLY1Hr.

WEEKLY

SIMPLE

AUTO OFF

A

C

D
E

F

G H

J K

M

I

L

N

O
P

B

1

Set Temperature buttons

 Down

 Up

2

Timer Menu button (Monitor/Set button)

3

Mode button (Return button)

4

Set Time buttons

 Back

 Ahead

5

Timer On/Off button (Set Day button)

6

Louver button (

 Operation button)

 To preceding operation number.

7

Ventilation button (

 Operation button)

 

 To next operation number.

8

ON/OFF button

9

Fan Speed button

Opening the door.

0

Filter 

 button (<Enter> button)

A

Test Run button

B

Check button (Clear button)

C

Airflow Up/Down button

Notes:

If you press a button for a feature that is not installed at the indoor unit,
the remote controller will display the “Not Available” message.

If you are using the remote controller to drive multiple indoor units, this
message will appear only if the feature is not present at the parent unit.

Never expose the remote controller to direct sunlight. Doing so can re-
sult in the erroneous measurement of room temperature.

Never place any obstacle around the lower right-hand section of the re-
mote controller. Doing so can result in the erroneous measurement of
room temperature.

A

Day-of-Week

Shows the current day of the week.

Time/Timer Display

Shows the current time, unless the simple or Auto Off timer is set.
If the simple or Auto Off timer is set, shows the time remaining.

B

“Sensor” indication

Displayed when the remote controller sensor is used.

C

Identifies the current operation

Shows the operating mode, etc.
* Multilanguage display is supported.

D

“Centrally Controlled” indicator

Indicates that operation of the remote controller has been prohibited by a main controller.

E

“Timer Is Off” indicator

Indicates that the timer is off.

F

Temperature Setting

Shows the target temperature.

G

Up/Down Air Direction indicator

The indicator 

 shows the direction of the outcoming airflow.

H

“One Hour Only” indicator

Displayed if the airflow is set to weak and downward during COOL or DRY mode. (Opera-
tion varies according to model.)
The indicator goes off after one hour, at which time the airflow direction also changes.

I

Louver display

Indicates the action of the swing louver. Does not appear if the louver is stationary.

J

Room Temperature  display

Shows the room temperature.

K

 (Power On indicator)

Indicates that the power is on.

L

Ventilation indicator

Appears when the unit is running in Ventilation mode.

M

Fan Speed indicator

Shows the selected fan speed.

N

“Locked” indicator

Indicates that remote controller buttons have been locked.

O

“Clean The Filter” indicator

Comes on when it is time to clean the filter.

P

Timer indicators

The indicator comes on if the corresponding timer is set.

Note:

For purposes of this explanation, all parts of the display are shown as lit.
During actual operation, only the relevant items will be lit.

Remote controller-Button

Remote controller-Display

3. Operation

WT05223X02_en

08.2.18, 5:37 PM

5

Содержание PEA-RP200 GA

Страница 1: ...Air Conditioners INDOOR UNIT PEA RP170 200 250 WGA FOR USER OPERATION MANUAL For safe and correct use please read this operation manual thoroughly before operating the air conditioner unit GB ...

Страница 2: ...2 GB D F SW I NL E P 2 Fig 2 0 1 A Air outlet B Air inlet C Air filter Fig 2 0 2 A B C A LCD remote controller ON OFF TEMP A 5 A C B D Fig 5 0 1 A Air outlet C Air filter B Air inlet D Air filter handle ...

Страница 3: ...event damage to the unit Symbols put on the unit Indicates an action that must be avoided Indicates that important instructions must be followed Indicates a part which must be grounded Beware of electric shock This symbol is displayed on the main unit label Color yellow Warning Carefully read the labels affixed to the main unit 1 1 Installation s After you have read this manual keep it and the Ins...

Страница 4: ...aler Otherwise a breakdown electric shock or fire may result When you notice exceptionally abnormal noise or vibration stop opera tion turn off the power switch and contact your dealer Do not over cool The most suitable inside temperature is one that is within 5 C of the outside temperature Do not leave handicapped people or infants sitting or standing in the path of the airflow from the air condi...

Страница 5: ...nt time unless the simple or Auto Off timer is set If the simple or Auto Off timer is set shows the time remaining B Sensor indication Displayed when the remote controller sensor is used C Identifies the current operation Shows the operating mode etc Multilanguage display is supported D Centrally Controlled indicator Indicates that operation of the remote controller has been prohibited by a main c...

Страница 6: ... keep the humidity low For heating Press the 2 2 2 2 2 operation mode button to bring up the HEAT display Regarding displays during heating operation DEFROST Displayed only during the defrosting operation STAND BY Displayed from the start of heating operation until the moment warm air blows out For automatic cooling heating Press the 2 2 2 2 2 operation mode button to bring up the AUTO display Cau...

Страница 7: ... Selection of remote controller refer to Installation Manual s How to Set the Day of the Week and Time 1 Press the or Set Time button A to show display 2 2 Press the Timer On Off Set Day button 9 to set the day Each press advances the day shown at 3 Sun Mon Fri Sat 3 Press the appropriate Set Time button A as necessary to set the time As you hold the button down the time at 4 will increment first ...

Страница 8: ...imer indicator is visible in the display at 1 When something other than the Simple Timer is displayed set it to SIMPLE TIMER using the function selection of remote controller see Installation Manual 2 Press the Timer Menu button B so that the Set Up appears on the screen at 2 Note that each press of the button toggles the display between Set Up and Monitor 3 Press the ON OFF button 1 to display th...

Страница 9: ... Hr AFTER SIMPLE ON Hr AFTER SIMPLE C C SIMPLE At 2 hours after timer start At Timer Start At 5 hours after timer start Display shows the tim er s OFF setting hours remaining to OFF Display changes to show the timer s ON setting hours remain ing to ON The time displayed is ON set ting 5 hours OFF setting 2 hours 3 hours The air conditioner comes on and will continue to run until someone turns it o...

Страница 10: ...ou can use the Func tion Selection of remote controller to select which type of lock to use For information about selecting the lock type see Installation Manual Specifically you can use either of the following two lock types 1 Lock All Buttons Locks all of the buttons on the remote controller 2 Lock All Except ON OFF Locks all buttons other than the ON OFF button Note The Locked indicator appears...

Страница 11: ...acuum cleaner In the case of severe staining wash the filter in lukewarm water mixed with dissolved neutral detergent or water and then rinse off the detergent completely After washing dry it and fix it back into place Caution Do not dry the filter by exposing it to direct sunlight or warming it using fire etc Doing so can result in the deformation of the filter Washing it in hot water more than 5...

Страница 12: ...mmand sent from the remote controller Find out if the remote controller was used Is the indicator lit Find out if the remote controller was used PLEASE WAIT is displayed in the remote controller An automatic startup test is being performed will last for about two minutes An error code is displayed in the remote controller A self diagnostic function is being performed to preserve the air conditione...

Страница 13: ...ils consult with your dealer In some types of installation sites the installation of an earth leakage breaker is mandatory For details consult with your dealer Regarding transfer of installation When removing and reinstalling the air conditioner when you enlarge your home remodel or move consult with your dealer in advance to ascertain the cost of the professional engineering work required for tra...

Страница 14: ......

Страница 15: ......

Страница 16: ...WT05223X02 Please be sure to put the contact address telephone number on this manual before handing it to the customer HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN ...

Отзывы: