24
7
WIRING DIAGRAM
SYMBOL
NAME
C1
FAN MOTOR CAPACITOR
CN120<I.B>
REMOTE CONTROLLER TRANSMISSION WIRE
CONNECTOR
CN51<I.B>
REMOTE INDICATOR CONNECTOR
CNR120<R.B>
REMOTE CONTROLLER TRANSMISSION WIRE
CONNECTOR
FI,2<I.B>
FUSE (6.3A 250V)
I.B
INDOOR CONTROLLER BOARD
LD1<R.B>
RUN INDICATOR LED
LD3<R.B>
COOLING INDICATOR LED
LD4<R.B>
FAN MODE INDICATOR LED
LD5<R.B>
FAN HIGH INDICATOR LED
LD7<R.B>
INDICATOR MODE TEMPERATURE LED
LD8<R.B>
INDICATOR MODE TIMER LED
LD9<R.B>
DRY INDICATOR LED
LD10<R.B>
FAN LOW INDICATOR LED
LD11<R.B>
OFF TIMER INDICATOR LED
LD12<R.B>
ON TIMER INDICATOR LED
SYMBOL
NAME
LD13-24<R.B>
TEMPERATURE / TIMER REMAINING TIME
INDICATOR LED
MF1
INDOOR FAN MOTOR
SW1<I.B>
FUNCTION SWITCH
SW2<I.B>
UNIT SWITCH
SW3<I.B>
EMERGENCY OPERATION SWITCH
SW1<R.B>
ON / OFF SWITCH
SW2<R.B>
OPERATION MODE SWITCH
SW3<R.B>
FAN HIGH / LOW SWITCH
SW5<R.B>
INDICATOR SWITCH
SW6<R.B>
TEMPERATURE TIMER SETTING UP SWITCH
SW7<R.B>
TEMPERATURE TIMER SETTING DOWN
SWITCH
SW8<R.B>
TIMER CONTINUOUS ON / OFF SWITCH
SYMBOL
NAME
R.B
REMOTE CONTROLLER BOARD
T
TRANSFORMER
TB1
POWER SUPPLY TERMINAL BLOCK
TB2
INDOOR / OUTDOOR CONNECTING WIRE TER-
MINAL BLOCK
RT1
ROOM TEMPERATURE THERMISTOR
(0°C / 15k
Ω
, 25°C / 5.4k
Ω
DETECT)
RT2
INDOOR COIL THERMISTOR
( 0°C / 15k
Ω
, 25°C / 5.4k
Ω
DETECT)
X5<I.B>
FAN MOTOR AUXILIARY RELAY
X6<I.B>
FAN MOTOR AUXILIARY RELAY
ZNR<I.B>
VARISTOR
JR
FUNCTION SELECTOR JUMPER RESISTORS
NOTES:
1. Since the indoor transformer (T) is connected with 220V wiring, if 230V or 240V power is used, change the wiring connection as shown fig : 1
w
.
When power supply is
Since the indoor fan motor (MF1) is connected with 220V 60Hz power, if 200V~240V 50Hz power is used, change the wiring connection as shown fig : 2
w
.
Indoor fan motor (MF1)
for 200V ~ 240V 50Hz.
2. Be sure to refer the outdoor unit electric wiring diagram before wiring of outdoor side unit.
3. Symbols used in wiring diagram above are.
/
: Terminal block, : Connector.
4. Emergency operation
If remote controller or microcomputer fails but there is no other trouble, emergency operation is possible by setting dip switch [SW3<I. B>] on the indoor con-
troller board.
[Check items]
(1) Compressor and fan.
(2) Check the trouble position using self diagnostic function. If the result of self diagnosis indicates protective device such as freeze protection is functioning emer-
gency operation is not possible unless the cause is removed.
(3) In emergency operation, the operation made by only ON / OFF circuit breaker manually [ON / OFF with remote controller is not possible].
[Emergency operation procedure]
(1) Cooling is possible by setting
1
.
2
ON and
3
OFF for the dip switch (SW3<I.B>) at indoor controller board.
(2) Turn on outdoor unit side circuit breaker, then indoor unit side circuit breaker in this order.
(3) During emergency operation indoor fan runs at high.
(4) Thermostat will not function.
(5) Do not cooling for more than 10 hours (the indoor unit heat exchanger can freeze).
DWG NO. BG79N636H01
fig
w
2
fig
w
1
JR
01 02 03 04 05 06
Remote control transmission line
DC 12V with 12 core connector
Indoor unit
ORN
RED
C1
T
BLK
YL
W
6
7
LD9
X6
X5
220V
60Hz
POWER SUPPLY
~ (1 PHASE)
220-240V
50Hz
TB1
N
L
GRN/YLW
BLU
RED
14.5VAC
10.6VAC
BLU
BLK
4
3
2
MF1
WHT
5
1
220V
230V
240V
RED
ORN
YL
W
TWIN-2
CN2B
OFF
ON
3
2
1
3
2
1
3 4
2
1
SW3
I.B
FAN1
BLU
X6
X5
5
3
1
CN2A
TWIN-1
POWER
CND
3
1
ZNR
F2
F1
BLU
RED
CNT
BRN
BRN
RED
RED
YL
W
WHT
SW1
OFF
ON
SW2
CN20
3 4
2
1
3
1
CN50
Remote controller
TO.RC
R.B
LD24
SW8
LD23
LD22
LD21
LD20
LD19
LD18
LD17
LD16
LD15
LD14
LD13
LD12
LD11
LD10
LD5
LD4
LD3
LD1
LD7
SW7
SW6
SW5
SW3
LD8
CNR120
SW2
SW1
TO OUTDOOR UNIT
CONNECTING WIRES
DC 12V(non-polar)
TRANS
YLW
ORN
HEA
TER
CN31
13
2
INTAKE
RT1
12
PIPE
CN21
RT2
12
TIMER
CN28
L.TEST
CN2
CN30
12
3
DRAIN
35
4
2
1
OUTDOOR
MUL
TIPLE
CN51
CN120
TB2
11
2
2
1
CN4T
TRANS
240 YELLOW
240V
230 ORANGE
230V
220 RED
LD
YELLOW
BLUE
LD
200—220 230—240
220
BLUE
PE-3EJA
2
.TH / PE-3EJA
3
.TH / PE-4EJSA
2
.TH / PE-5EJSA
2
.TH / PE-6EJSA
2
.TH
OC155-B--1.qxp 7/26/00 4:43 PM Page 24