・Incomplete installation could cause electric shock, fire, etc.

・After using this manual, be sure to pass it to the customer together with the instruction manual provided with indoor unit.  Ask the customer to keep this installation manual and the  

instruction manual in a handy place, and to show them to the engineer when the air-conditioner is moved or repaired. Also ask the customer to pass them to any new user.

・Read these "safety Precautions" thoroughly and install securely.  
・Precautions are classified using the following symbols depending on the extent and type of danger by erroneous handling.

Make sure that the following components, along with this manual, are 
packed in the box.

●Open  the  intake  grill  and  remove  the  corner  panel  where  refrigerant  pipes  are  and  where  local  wires  are 

drawn into. 

 ※The corner panel removed is not needed. 
●Remove  the  thermistor  for  room  temperature  fixed  by  1  screw  and  the  control  box  cover  fixed  by  3 

screws,which is possible to hang temporarily.

Remote control holder can be used for keeping the remote controller on the wall.

Fitting remote controller into holder 

 

 ① Fix the remote control holder to the wall using 
   the two wood screws provided. 
 ② Insert the remote controller into the holder. 
  
Removing remote control 

 

 ●Pull out the remote controller.

●Bring  the  cable  of  wireless  receiving  unit  through  the  square  hole 

underneath  the  corner  panel  removed  where  refrigerant  pipes  are  and 
where local wires are drawn into. 

●As  shown  in  the  figure,pull  the  cable  into  the  inside  of  the  control  box 

and  connect  it  to  CN90  on  the  indoor  controller  board.  Then  fix  the 
cable by the clamp, being able to remove the receiving unit afterwards in 
case.  

●Slide  the  receiving  unit  in  the 

  direction  as  shown  and  fix  it  by  the 

screw which is  used for the corner panel removed. 

●After  the  installation  completed,  set  the  control  box  and  the  thermistor 

as they were . 

・Incomplete installation could cause electric shock, fire, etc.

・Otherwise, the unit could fall, which could cause injury.

・Shortage in electrical circuit capacity or incomplete construction could cause fire, etc.

・Modification or incorrect repair could cause electric shock, fire, etc. Consult the dealer 

from whom you purchased the unit.

・Incomplete installation could cause electric shock, fire, etc.Ask the dealer or a specialist 

for installation.

              

            

・Tension on wires could disconnect them, or cause heat, fire, etc.

                

・Doing so could cause fault, electric shock, etc.

          

・Failure to do so could cause fault, electric shock, etc.

       

・Failure to do so could cause fault, electric shock, etc.

       

・Failure to do so could cause fault, fire, etc.

                  

                

            

・Usage in a place where there is much oil  (including machine oil),  steam, sulfide gas, 

etc. could greatly degrade its performance or damage components.

           

・This  unit  could  malfunction  when  affected  by  inverter  equipment,  private  electric  generator,  high-frequency  medical  instruments,  radio  communication  devices,  etc.  Also,  this  unit 

could adversely affect medical instruments, communication devices, etc., thus interfering with human medical treatment, or causing disturbance in broadcast pictures or noise.

                           

・If gas leaks or accumulates around the unit, it could cause ignition, explosion, etc.

               

・Avoid  installing  in  a  wall  where  condensation  occurs.  Installing  in  such  a  place  could 

cause a fault, electric shock, etc.

                      

・Installing in such a place could cause fault, electric shock, etc.

                         ! 

       

          "         

   #         

   

・Incomplete connection or fixing could cause heat, fire, etc.

           $       

      $     

・Installing in such a place could cause deformation, fault, etc.

                   %&

 

&

  $     

CAUTION

WARNING

CAUTION

WARNING

Erroneous handling can cause death or serious injury.

This manual describes the installation for wireless remote controller of the Mitsubishi package air-conditioner.  
Read this manual or unit's installation manual carefully.

Mitsubishi Package Air-Conditioner

Installation Manual

Erroneous handling can cause personal injury or damage.

Wireless Remote Controller Kit 
PAR-SW96U-E

Component

Wireless Receiving Unit (Corner Panel) 
Wireless remote controller   
Remote control holder  
"AAA" LR03 alkaline batteries  
4.1x16 wood screws  





2

PAR−SW96U−E

Note       The remote signal will reach the receiver over a distance of approx. 7 m in a straight 

line and approx. 45゜

 left or right. If the infrared receiver is affected by fluorescent light 

(especially, inverter type), it    may not be able to receive the signal. Take this into 
consideration when installing fluorescent lights or replacing them.

Wireless Receiving Unit 
(Corner Panel) 

Screw

Indoor Controller 
Board CN90

Cable

Cramp

Square hole

ペアNO. 

J41

J42

Indoor Unit

Grill

Refrigerant pipes

Corner Panel

Screw

Screw

Screw

Indoor 

Controller  

Board

Jumper Wire

Cont. Box Cover

Intake Grill

Intake Sensor

※Turn off the main power before work.

RG79D052H01

Отзывы: