background image

OPTIONAL

PAR
TS

20

2) How To Install

[Fig. 8-8] to [Fig. 8-15] 

1. Common items for “Installation on the ceiling” and “Installation on the switch

box or on the wall”

[Fig. 8-8] 

A

Signal receiving unit external

E

6.5 mm (1/4 inch)

B

Center of Switch box

F

70 mm (2 - 3/4 inch)

C

Switch box

G

83.5 ± 0.4 mm (3 - 9/32 inch)

D

Installation pitch

H

Protrusion (pillar, etc)

[Fig. 8-9] 

A

Remote controller wire

B

Hole (drill a hole on the ceiling to pass the remote controller wire.)

C

Signal Receiving Unit

(1) Select the installation site.

The following must be observed.

1

Connect the signal receiving unit to the indoor unit with the supplied remote

controller wire. Note that the length of the remote controller wire is 5 m (16 ft).
Install the remote controller within the reach of the remote controller wire.

2

When installing on either the switch box or the wall, allow space around the

Signal Receiving Unit as shown in the figure in [Fig. 8-8].

3

When installing the Signal Receiving Unit to the switch box, the Signal Re-

ceiving Unit slipped downward for 6.5 mm (1/4 inch) as right illustrated.

4

Parts which must be supplied on site.

Switch box for one unit
Thin-copper wiring pipe
Lock nut and bushing

5

The thickness of the ceiling to which the remote controller is installed must be

between 9 mm (3/8 inch) and 25 mm (1 inch).

6

Install the unit on the ceiling or on the wall where the signal can be received

from the wireless remote controller.

The  area  where  the  signal  from  the  wireless  remote  controller  can  be  re-

ceived is 45 ° and 7 m (22 ft) away from the front of the signal receiving unit.

7

Install the signal receiving unit to the position depending on the indoor unit

model.

Connect the remote controller wire securely to the order wire. To pass the
remote controller wire through the conduit, follow the procedure as shown in

[

Fig. 8-10

]

.

[Fig. 8-10] 

A

Fix tightly with tape.

C

Order wire

B

Remote controller wire

Note:

The point where the remote controller wire is connected differs depending
on the indoor unit model.
Take into account that the remote controller wire cannot be extended when
selecting the installation site.

lf the Signal Receiving Unit is installed near a fluorescent lamp specially
inverter type,signal interception may occur.
Be careful for installing the Signal Receiving Unit or replacing the lamp.

(2) Use the remote controller wire to connect it to the connector (CN90) on the

controller circuit board on the indoor unit.
Refer  to  the  2)  Setting  the  Pair  Number  Switch  for  details  on  controller  circuit
board on the indoor unit.

(3) Seal the Signal Receiving Unit cord lead-in hole with putty in order to pre-

vent the possible entry of dew, water droplets, cockroaches, other insects,
etc.

[Fig. 8-11]

A

150 mm (5 - 15/16 inch)

B

Remote controller wire (Accessory)

C

Wiring pipe

D

Locknut

E

Bushing

F

Switch box

G

Seal around here with putty

• When installing on the switch box, seal the connections between the switch

box and wiring pipe with putty.

[Fig. 8-11] 

H

Seal around here with putty

I

Remote controller wire

J

Seal around here with putty

• When opening a hole using a drill for Signal Receiving Unit wire (or taking the

wire out of the back of the Signal Receiving Unit), seal that hole with putty.

• When routing the wire via the portion cut off from the upper case, equally seal

that portion with putty.

(4) Install the remote control wire to the terminal block. [Fig. 8-12] 

(5) Installing hole when the Signal Receiving Unit is installed on the wall direct.

[Fig. 8-13] 
• Cut the thin-wall portion inside the bottom case (oblique section) by a knife or a

nipper.

• Take out the connected remote controller wire to the terminal brock through

this space.

(6) Install the lower case on the switch box or directly on the wall. [Fig. 8-14] 

Mounting the cover [Fig. 8-15] 

 Caution:

• Insert the cover securely until the clicking sound is made. If not doing so, the

cover may fall.

  

Signal Receiving Unit

1) Sample system connection

[Fig. 8-7] 

Only the wiring from the signal receiving unit and between the remote controllers is
shown in [Fig. 8-7]. The wiring differs depending on the unit to be connected or the
system to be used.
For details on restrictions, refer to the installation manual or the service handbook
that came with the unit.
1. Connecting to Mr. SLIM air conditioner
(1) Standard 1:1

1

Connecting the signal receiving unit

Connect the signal receiving unit to the CN90 (Connect to the wireless re-
mote controller board) on the indoor unit using the supplied remote controller
wire. Connect the signal receiving units to all the indoor units.

°

2. Setting example
(1) To use the units in the same room

[Fig. 8-17] (P.10)

1

Separate setting
Assign a different pair number to each indoor unit to operate each indoor unit
by its own wireless remote controller.

[Fig. 8-18] (P.10)

2

Single setting
Assign the same pair number to all the indoor units to operate all the indoor
units by a single wireless remote controller.

[Fig. 8-19] (P.10)

(2) To use the units in different rooms

Assign the same pair number to the wireless remote controller as that of the
indoor unit. (Leave the setting as it is at purchase.)

2) Setting the Model No.

[Fig. 8-20] (P.10)

1

Insert batteries.

2

Press the SET button with something sharp at the end.

MODEL SELECT

 blinke and Model No. lighted.

3

Press the temp 

 button to set the Model No.

4

Press the SET button with something sharp at the end.

MODEL SELECT

 and Model No. are lighted for three seconds, then turned off.

8.4.3. Setting

1) Setting the pair number switch

[Fig. 8-16] 

1. Setting method

Assign the same pair number to the wireless remote controller as that of the in-
door unit. If not doing so, the remote controller cannot be operated. Refer to the
installation manual that came with the wireless remote controller for how to set
pair numbers of wireless remote controllers.
Position of daisy wire on the controller circuit board on the indoor unit.

Controller circuit board on the indoor unit (reference) [Fig. 8-16] 

A

 CN90: Connector for remote controller wire connection

For pair number settings, the following 4 patters (A-D) are available.

Pair number

setting pattern

Pair number on

remote controller side

Indoor controller circuit board side Point

where the daisy wire is disconnected

A
B
C
D

0
1
2

3~9

Not disconnected
J41 disconnected
J42 disconnected

J41 and J42 disconnected

Indoor Unit Model

Model No.

PEAD

026

Emergency Operation for Wireless Remote-controller

ON/OFF

HEAT

COOL

ON/OFF lamp

(lit when unit is operating; unlit when unit is

not operating)

Emergency operation

In cases where the remote control unit does not operate properly,

use either the

COOL or

HEAT button on the wireless remote

control signal receiver to toggle the unit on or off. On cooler only units,

pushingthe

HEAT  button toggles the fan on and off.

Pressing the

COOL or

HEAT button selects the following settings.

Operation mode

COOL

HEAT

Preset temperature

24

o

C/75

o

F

24

o

C/75

o

F

Fan speed

High

High

Signal reciever   

PAR-SA9CA-E

Содержание PAR-SA9CA-E

Страница 1: ...E Unit mm Descriptions Applicable Models Dimensions ON OFF 120 H 70 W 22 5 D mm external dimensions Content Item DC12V supplied from indoor unit control Power Tempreture 0 40 Humidity 30 90 RH no condensing Colour Munsell White Grey 4 8Y7 92 0 66 Material ABS 0 2kg Weight 9 9 83 5 19 4 8 35 2 9 2 4 6 22 5 120 70 ON OFF COOL HEAT ...

Страница 2: ...A Fix tightly with tape B Remote controller wire C Order wire Indoor unit Fig 8 8 Fig 8 11 H J I When using the switch box When installing directly on the wall A 150 mm 5 15 16 inch B Remote controller wire Accessory C Wiring pipe D Locknut H Seal around here with putty I Remote controller wire J Seal around here with putty E Bushing F Switch box G Seal around here with putty C D B F E G A Wall 8 ...

Страница 3: ... directly on the wall or the ceiling use wood screws Insert the minus screwdriver toward the arrow pointed and wrench it to remove the cover A flat screwdriver whose width of blade is between 4 and 7mm 5 32 9 32inch must be used Fig 8 15 1 1 2 A 1 Hang the cover to the upper hooks 2 places 2 Mount the cover to the lower case A Cross section of upper hooks Signal reciever PAR SA9CA E ...

Страница 4: ...al block Fig 8 12 5 Installing hole when the Signal Receiving Unit is installed on the wall direct Fig 8 13 Cut the thin wall portion inside the bottom case oblique section by a knife or a nipper Take out the connected remote controller wire to the terminal brock through this space 6 Install the lower case on the switch box or directly on the wall Fig 8 14 Mounting the cover Fig 8 15 Caution Inser...

Отзывы: