• Confirm that the box contains the following parts.
* In addition to the parts mentioned above, other parts need to be procured locally in order to operate this device. Furthermore, other Mitsubishi optional
parts may be required depending on how the device is to be used.
For details, refer to "6 Installation Method".
4-1. Product Specifications
*1: Supply electric power from a power supply unit for the transmission line or an outdoor unit. Furthermore, the power consumption factor of the M-NET
circuitry of this unit is "1/4" (equivalent to one ME Remote Controller).
*2: Configure the dip switch settings for the analog input method to use while referring to "9 Switch List".
*3: The measurement error for the system includes the measurement error for this unit, sensor, and wiring.
*4: Settings for the interlock function are performed from the maintenance tool. For details, refer to the instruction manual for the Maintenance Tool.
4-2. External View
3
Confirmation of Parts
Number
Part Name
Quantity
1
AI controller
1
2
Installation/instruction manual (this document)
1
4
Specifications
Item
Description
Power Supply
24 VDC±10%: 5 W
Screw terminal
block (M3)
Interface
M-NET communication
17 to 30 VDC (*1)
Screw terminal
block (M3)
Input
Ch
Sensor
Measurement
target
Measurement
range
Measurement error
External connection
method
Ch1
Pt100
(3-wire system)
Temperature
-30 to 60°C
[-22 to 140°F]
±0.3%FS ±0.1°C (0.18°F) (*3)
[at 25°C (77°F)]
Screwless terminal
block (3 poles)
Analog
4 to 20 mADC
Temperature/
humidity
(Set by system
controller)
±0.5%FS ±0.1°C (0.18°F) (*3)
±0.5%FS ±0.1%RH
[at 25°C (77°F)]
Screwless terminal
block (2 poles)
1 to 5 VDC
0 to 10 VDC
Ch2
Analog
4 to 20 mADC
Temperature/
humidity
(Set by system
controller)
±0.5%FS ±0.1°C (0.18°F) (*3)
±0.5%FS ±0.1%RH
[at 25°C (77°F)]
Screwless terminal
block (2 poles)
1 to 5 VDC
(*2)
0 to 10 VDC
Output
Upper/lower limit
alarm output
(non-voltage contact)
Applied load
MAX: 24 VDC, 5 W
MIN: 5 VDC, 2 mW
* AC loads cannot be connected.
Screw terminal
block (M3.5)
Interlock
Function
Interlock M-NET devices according to measurement data values. (*4)
Environment
Conditions
Temperature
Operating temperature range
0 to 40°C [32°F to 104°F]
Storage temperature range
-20 to 60°C [-4°F to 140°F]
Humidity
30 to 90%RH (no condensation)
Dimensions
200 (W) × 120 (H) × 45 (D) mm / 7
7
/
8
(W) × 4
3
/
4
(H) × 1
25
/
32
(D) in
Weight
0.6 kg / 1 3/8 lb
Current Time
Power Failure
Backup
If the power is cut, an internal capacitor will normally keep counting the current time for approximately one week.
(The internal capacitor takes approximately a day to charge. Replacement of a battery is not necessary.)
Installation
Environment
Inside a control panel (indoors)
* Use this product in a hotel, a business office environment or similar environment.
[ 24 VDC Power Supply]
N623
Al controller
PAC-YG63MCA
MODEL
SERVICE REF. PAC-
INPUT
WEIGHT
SERIAL No.
MADE IN JAPAN
YG60MCA-J
VOLTAGE
DC24V;0.2A
0.6 kg / 1 /
3 8
lb
Al controller
PAC-YG63MCA
[ Output LEDs ]
Alarm
Alarm
Ch2
Ch1
[ OUTPUT ] Non-voltage Contact Output
Alarm
Alarm
Ch2
Ch1
[ INPUT ]
Pt100
4 to 20 mA / 1 to 5 V / 0 to 10 V
4 to 20 mA / 1 to 5 V / 0 to 10 V
Ch1
Ch2
harmful interference, and (2)this device must accept any interference
received, including interference that may cause undesired operation.
subject to the following two conditions: (1)this device may not cause
This device complies with Part15 of the FCC Rules.Operation is
200
(
7
7
/
8
)
46
(
1
13
/
16
)
26
(
1
1
/
32
)
45
(
1
25
/
32
)
9
(
3
/
8
)
15
(
19
/
32
)
11
0
(
4
11
/
32
)
26
(
1
1
/
32
)
120
(
4
3
/
4
)
150
(
5
29
/
32
)
26
(
1
1
/
32
)
83.5
(
3
5
/
16
)
27
(
1
3
/
32
)
4.5
(
3
/
16
)
Unit: mm (in)