6
Rack of the equipment system
Securing the printer in the rack of the equipment system
In accordance with the screw hole positions
shown on the printer bottom view, make four
screw holes (3.5 mm in diameter) in the shelf
of the rack.
Place the printer on the shelf, align the screw
holes of the printer with those of the shelf,
and secure the printer by tightening the
screws (four M3 screws, 6 mm long) from the
bottom.
Ensuring proper grounding of the printer
To ensure that the printer is grounded properly, you are recommended to use either of the
following methods.
• Secure the printer on the metal chassis of the system that has been grounded using
a screw.
• Connect the printer to the earth part of the system using a wire.
Attach an M3 ring connector (Ø7.5 mm or less) at the end of a 16 AWG wire and fit the
connector to the EARTH part of the printer using an earth screw.
16 AWG wire
M3 ring connector
Ø7.5 mm or less
EARTH part of the printer
Earth part
of the
system
Earth screw
55
48.2
100
120
130
154
4
EXAMPLE OF INSTALLATION INTO EQUIPMENT SYSTEM
Example of installation in the rack of the equipment system