6 INSTALLATION AND WIRING
6.9 Wiring of I/O Module and External Device
147
6
Wiring of waterproof connectors
Applicable connectors and cables
For connectors and cables that can be used for the I/O module (waterproof module), refer to the following.
Page 148 List of Recommended Cables/Connectors for the I/O Module (Waterproof Module)
Signal names and wiring
For the signal names of the connectors and wiring of the external device, refer to the specifications of each module. (
Page 22 Performance Specifications)
Incorrect wiring can cause malfunction of or damage on the module.
Connecting
1.
Insert the I/O cable connector into the I/O module (waterproof module). Pay attention to the connector's orientation.
2.
Tighten the I/O cable connector.
Disconnecting
1.
Loosen the I/O cable connector and remove the cable.
If the I/O cable is damp, the connector's resin part of the module may get wet from the moisture on the cable
at its removal. Dry or wipe up the water from the resin part for re-connecting the I/O cable.