55
CHAPTER 3 SPECIFICATIONS
3
3.
7
List
s of
R
e
mot
e
B
u
ffer
Mem
o
ry
Areas
*1
The default value depends on the mode used. For details on the default value, refer to the following.
*2
This column indicates whether data can be read from or written to the remote buffer memory area through sequence
programs.
R: Reading enabled
W: Writing enabled
*3
This column indicates whether the setting in the remote buffer memory area is automatically changed when the input
range is changed. For details, refer to the following.
*4
This column indicates whether data can be written to the non-volatile memory by turning off and on Set value backup
instruction (RY15). For details, refer to the following.
*5
This column indicates whether or not the setting can be changed by turning off and on During operation setting change
instruction (RY10). For details, refer to the following.
*6
This column indicates whether or not the setting can be changed by turning off and on Initial data setting request flag
(RY9) when all channels stop. For details, refer to the following.
*7
(TT) represents NZ2GF2B-60TCTT4. (RT) represents NZ2GF2B-60TCRT4.
*8
Available only when the NZ2GF2B-60TCTT4 is used. With other models, this area is handled as a system area.
652(28CH)
CH3
Sensor two-point correction
offset value (measured
value)
0
R/W
653(28DH)
CH3
Sensor two-point correction
offset value (corrected value)
0
R/W
654(28EH)
CH3
Sensor two-point correction
gain value (measured value)
0
R/W
655(28FH)
CH3
Sensor two-point correction
gain value (corrected value)
0
R/W
656 (290H)
CH4
Sensor two-point correction
offset value (measured
value)
0
R/W
657 (291H)
CH4
Sensor two-point correction
offset value (corrected value)
0
R/W
658 (292H)
CH4
Sensor two-point correction
gain value (measured value)
0
R/W
659 (293H)
CH4
Sensor two-point correction
gain value (corrected value)
0
R/W
660 to
1279(294H to
4FFH)
System area
Address
(decimal
(hexadecimal))
Target
channel
Setting contents
Default
value
*1
Read/Write
*2
Automatic
setting
*3
Non-
volatile
memory
write
availability
*4
Change
of setting
during
operation
*5
Change
of
setting
when all
channels
stop
*6
Reference
Temperature input mode
Содержание NZ2GF2B-60TCRT4
Страница 1: ...CC Link IE Field Network Temperature Control Module User s Manual NZ2GF2B 60TCTT4 NZ2GF2B 60TCRT4 ...
Страница 2: ......
Страница 86: ...84 Memo ...
Страница 233: ...231 CHAPTER 8 FUNCTIONS 8 8 4 CC Link IE Field Network Function 3 Click the OK button on the following window ...
Страница 268: ...266 Memo ...
Страница 377: ...375 APPENDICES A Appendix 6 External Dimensions Memo ...
Страница 383: ...I 4 4 7 8 381 Memo ...
Страница 387: ......