70
MXZ-A26WV -
MXZ-A32WV -
Outdoor Power board
E1
E1
1
3
325-370V DC
Output
(Red)
(White)
Connect to the compressor
Voltage among phases: 5V to 180V
Connect to
the earth
CN5
Primary current detection
(Connect to the noise filter)
CN2
Connect to the controller board
(+)1-5(–): Signal transmission (To electronic control P.C. board)
5V DC pulse wave
(+)2-5(–): Zero cross signal
3-4 : Not used
(+)6-5(–): 15V
(+)7-5(–): 15V
(+)
(–)
Signal
reception
(From
electronic
control P.C.
board)
5V DC
pulse wave
)
CN3
Fin temperature thermistor
OB319--3.qxp 03.12.3 0:58 PM Page 70