1-1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY

•  Be sure to read “THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY” before installing the air conditioner.

•  Be sure to observe the warnings and cautions specified here as they include important items related to safety.

•  After reading this manual, be sure to keep it together with the OPERATING INSTRUCTIONS for future reference.

•  Equipment complying with IEC/EN 61000-3-12.

1-2. SPECIFICATIONS

 

CAUTION

(Could lead to serious injury in particular environments when operated incorrectly.)

n

  Do not install the unit by yourself (user).

  Incomplete installation could cause fire or electric shock, injury due to the unit 

falling, or leakage of water. Consult the dealer from whom you purchased 

the unit or a qualified installer.

n

  Perform the installation securely referring to the installation manual.

  Incomplete installation could cause fire or electric shock, injury due to the 

unit falling, or leakage of water. 

n

  When installing the unit, use appropriate protective equipment and tools 

for safety.

  Failure to do so could cause injury.

n

  Install the unit securely in a place which can bear the weight of the unit.

  If the installation location cannot bear the weight of the unit, the unit could 

fall causing injury.

Perform electrical work according to the installation manual and be sure 

to use an exclusive circuit. Do not connect other electrical appliances 

to the circuit.

  If  the  capacity  of  the  power  circuit  is  insufficient  or  there  is  incomplete 

electrical work, it could result in a fire or an electric shock.

Do not damage the wires by applying excessive pressure with parts 

or screws.

  Damaged wires could cause fire.

Be sure to cut off the main power in case of setting up the indoor P.C. 

board or wiring works.

  Failure to do so could cause electric shock.

n

  Use  the  specified  wires  to  connect  the  indoor  and  outdoor  units 

securely and attach the wires firmly to the terminal block connecting 

sections so the stress of the wires is not applied to the sections.

  Incomplete connecting and securing could cause fire.

Do not install the unit in a place where inflammable gas may leak.

  If gas leaks and accumulates in the area around the unit, it could cause an 

explosion.

n

  Do not use intermediate connection of the power cord or the extension 

cord and do not connect many devices to one AC outlet.

  It could cause a fire or an electric shock due to defective contact, defective 

insulation, exceeding the permissible current, etc.

Be sure to use the parts provided or specified parts for the installation 

work.

  The use of defective parts could cause an injury or leakage of water due 

to a fire, an electric shock, the unit falling, etc.

When plugging the power supply plug into the outlet, make sure that 

there is no dust, clogging, or loose parts in both the outlet and the 

plug. Make sure that the power supply plug is pushed completely into 

the outlet. 

  If there is dust, clogging, or loose parts on the power supply plug or the 

outlet, it could cause electric shock or fire. If loose parts are found on the 

power supply plug, replace it.

Attach the electrical cover to the indoor unit and the service panel 

to the outdoor unit securely.

  If the electrical cover of the indoor unit and/or the service panel of the 

outdoor unit are not attached securely, it could result in a fire or an electric 

shock due to dust, water, etc.

When installing, relocating, or servicing the unit, make sure that no 

substance other than the specified refrigerant (R410A) enters the 

refrigerant circuit.

  Any presence of foreign substance such as air can cause abnormal pres-

sure rise and may result in explosion or injury. The use of any refrigerant 

other than that specified for the system will cause mechanical failure, 

system malfunction, or unit breakdown. In the worst case, this could lead 

to a serious impediment to securing product safety.

Do not discharge the refrigerant into the atmosphere. If refrigerant 

leaks during installation, ventilate the room.

  If refrigerant comes in contact with a fire, harmful gas could be generated.

Refrigerant leakage may cause suffocation. Provide ventilation in accordance 

with EN378-1.

Check that the refrigerant gas does not leak after installation has 

been completed.

  If refrigerant gas leaks indoors, and comes into contact with the flame 

of a fan heater, space heater, stove, etc., harmful substances will be 

generated.

Use appropriate tools and piping materials for installation. 

  The pressure of R410A is 1.6 times more than R22. Not using appropriate 

tools or materials and incomplete installation could cause the pipes to 

burst or injury. 

When pumping down the refrigerant, stop the compressor before 

disconnecting the refrigerant pipes.

  If the refrigerant pipes are disconnected while the compressor is running 

and the stop valve is open, air could be drawn in and the pressure in the 

refrigeration cycle could become abnormally high. This could cause the 

pipes to burst or injury. 

When installing the unit, securely connect the refrigerant pipes 

before starting the compressor.

  If the compressor is started before the refrigerant pipes are connected 

and when the stop valve is open, air could be drawn in and the pressure 

in the refrigeration cycle could become abnormally high. This could cause 

the pipes to burst or injury.

Fasten a flare nut with a torque wrench as specified in this manual.

  If fastened too tight, a flare nut may break after a long period and cause 

refrigerant leakage.

The unit shall be installed in accordance with national wiring regula-

tions. 

n

  Earth the unit correctly.

  Do not connect the earth to a gas pipe, water pipe, lightning rod or tel-

ephone earth. Defective earthing could cause electric shock.

n

   Install an earth leakage breaker depending on the installation place.

  If an earth leakage breaker is not installed, it could cause electric shock.

n

  Perform the drainage/piping work securely according to the installation 

manual.

  If there is defect in the drainage/piping work, water could drop from the unit, 

soaking and damaging household goods.

n

  Do not touch the air inlet or the aluminum fins of the outdoor unit.

  This could cause injury. 

n

  Do not install the outdoor unit where small animals may live.

  If small animals enter and touch the electric parts inside the unit, it could 

cause a malfunction, smoke emission, or fire. Also, advise user to keep 

the area around the unit clean. 

 

WARNING

(Could lead to death, serious injury, etc.)

*1  Connect to the power switch which has a gap of 3 mm or more when open 

to interrupt the source power phase. (When the power switch is shut off, it 

must interrupt all phases.)

*2  Use wires in conformity with design 60245 IEC 57. Use the indoor/outdoor 

connecting wire in conformity with the wire specifications specified in the 

installation manual of the indoor unit.

*3  Never use pipes with thickness less than specified. The pressure resistance 

will be insufficient.

*4  Use a copper pipe or a copper-alloy seamless pipe.

*5  Be careful not to crush or bend the pipe during pipe bending.

*6  Refrigerant pipe bending radius must be 100 mm or more.

*7  Insulation material : Heat resisting foam plastic 0.045 specific gravity

*8  Be sure to use the insulation of specified thickness. Excessive thickness 

may cause incorrect installation of the indoor unit and insufficient thickness 

may cause dew drippage.

*9  If the outdoor unit is installed higher than the indoor unit, max. height 

difference is reduced to 10 m.

*10 If pipe length exceeds 40 m, additional refrigerant (R410A) charge is re-

quired. (No additional charge is required for pipe length less than 40 m.)

  Additional refrigerant = A × (pipe length (m) - 40)

Required Tools for Installation

Phillips screwdriver

Level

Scale

Utility knife or scissors

Torque wrench

Wrench (or spanner)

4 mm hexagonal wrench

Flare tool for R410A

Gauge manifold for R410A

Vacuum pump for R410A

Charge hose for R410A

Pipe cutter with reamer

 ENGLISH

CONTENTS

1. BEFORE INSTALLATION ............................................................1

2. OUTDOOR UNIT INSTALLATION ...............................................4

3. FLARING WORK AND PIPE CONNECTION ...............................5

4. PURGING PROCEDURES, LEAK TEST, AND TEST RUN ......... 5

5. RELOCATION AND MAINTENANCE ..........................................7

Model

Power supply *1

Wire specifications *2

Pipe length and height difference *3, *4, *5, *6, *7, *8

Rated 

Voltage

Fre-

quency

Breaker 

capacity Power supply

Indoor/outdoor 

connecting 

wire

Max. pipe length 

per indoor unit / 

for multi-system

Max. height 

difference *9

Max. no. of bends 

per indoor unit / 

for multi system

Refrigerant adjust-

ment A *10

MXZ-4C80VA

230 V 50 Hz

25 A

3-core 2.5 mm

2

4-core 

1.0 / 1.5 mm

2

25 m / 70 m

15 m

25 / 70

20 g/m

25 m / 80 m

15 m

25 / 80

MXZ-5C100VA

1.  BEFORE INSTALLATION

JG79A366H03_en.indd   1

2016/03/02   8:49:49

Содержание MXZ-4C80VA

Страница 1: ... Για την εγκατάσταση της μονάδας εσωτερικού χώρου ανατρέξτε στο εγχειρίδιο εγκατάστασης της μονάδας εσωτερικού χώρου Manual de Instalação Para o INSTALADOR Este manual descreve apenas a instalação da unidade exterior Quando proceder à instalação da unidade interior consulte o manual de instalação da unidade interior Installationshåndbog Til INSTALLATØREN Denne håndbog beskriver kun hvordan udendør...

Страница 2: ...efrigerant gas does not leak after installation has been completed If refrigerant gas leaks indoors and comes into contact with the flame of a fan heater space heater stove etc harmful substances will be generated n Use appropriate tools and piping materials for installation The pressure of R410A is 1 6 times more than R22 Not using appropriate tools or materials and incomplete installation could ...

Страница 3: ...oil Salty places such as the seaside Where sulfide gas is generated such as a hot spring Where there is high frequency or wireless equipment Where there is emission of high levels of VOCs including phthalate compounds formaldehyde etc which may cause chemical cracking 500 or more 200 or more 350 or more 100 or more 1 Obstacles above When there is no obstacle in front and on the sides of the unit i...

Страница 4: ... 1 Note Place indoor outdoor unit connecting wire B and power supply cord A at least 1 m away from the TV antenna wire The Q ty for B to K in the above table is quantity to be used per indoor unit More than 100 mm Open as a rule More than 500 mm if the front and both sides are open More than 100 mm More than 200 mm if there are obstacles to both sides Open as a rule More than 500 mm if the back bo...

Страница 5: ...ng section of the terminal block 3 Firmly tighten the terminal screws to prevent them from loosening After tightening pull the wires lightly to confirm that they do not move 4 Perform 2 and 3 for each indoor unit 5 Connect power supply cord A 6 Fix indoor outdoor unit connecting wire B and power supply cord A with the cable clamps 7 Close the service panel securely Make sure that 3 2 PIPE CONNEC T...

Страница 6: ...ted 5 Check Compare the flared work with Fig 6 If flare is noted to be defective cut off the flared section and do flaring work again 1 Remove service port cap of stop valve on the side of the outdoor unit gas pipe The stop valves are fully closed and covered in caps in their initial state 2 Connect gauge manifold valve and vacuum pump to service port of stop valve on the gas pipe side of the outd...

Страница 7: ...1 on the outdoor controller board to OFF To lock the operation in HEAT mode set the same switch to ON 4 Turn on the main power for the air conditioner Description of the function With this function the operating noise of the outdoor unit can be lowered by reducing the operation load for example during nighttime in COOL mode However please note that the cooling and heating capacity may lower if thi...

Страница 8: ... the live parts may cause P C board damage To prevent electronic control P C board damage make sure to perform static elimination before operating this function This function does not operate when the outside temperature is 0 C or below LED indication during detection LED 1 Red 2 Yellow 3 Green Lighted Lighted Blinking Result of piping wiring correction function LED Result 1 Red 2 Yellow 3 Green L...

Страница 9: ...работающем компрессоре и открытом стопорном клапане возможно засасывание воздуха и чрезмерное повышение дав ления в контуре охлаждения Это может привести к разрыву труб или нанесению увечий n При установке прибора надежно подсоедините трубы с хладагентом до запуска компрессора Если компрессор запускается до подсоединения труб с хладагентом и при открытом стопорном клапане возможно засасывание возд...

Страница 10: ...нтально Производите установку в местах где отсутствует воздействие снегопада ветра и снега В районах с сильным снегопадом уста новите навес опору и или несколько отражательных перегородок Примечание Рекомендуется сделать трубную петлю рядом с наружным прибором для уменьшения передаваемой оттуда вибрации Примечание При эксплуатации кондиционера при низкой температуре наружно го воздуха обязательно ...

Страница 11: ... Воздуховыпускное отверстие 1 6 ТРУБОПРОВОДЫ ДРЕНАЖНОЙ СИСТЕМЫ НАРУЖНОГО БЛОКА Воздухозаборное отверстие 900 мм 500 мм 200 мм 2 U образные отверстия с пазом Болт основания M10 320 мм 2 12 мм 36 мм овальные отверстия Болт основания M10 355 мм 387 мм После проверки на отсутствие утечек плотно нанесите изо ляционный материал чтобы обеспечить отсутствие зазоров В случае крепления трубопро водов к стен...

Страница 12: ...е винты клеммной колодки для предотвраще ния их ослабления После затяжки винтов слегка потяните за про вода чтобы убедиться в их неподвижности 4 Выполните 2 и 3 для каждого внутреннего прибора 5 Подсоедините шнур электропитания А 6 Закрепите провод соединения внутреннего наружного приборов В и шнур электропитания А с помощью проводных зажимов 7 Надежно закройте сервисную панель Убедитесь что этап ...

Страница 13: ... виде запорные клапаны полностью закрыты и прикрыты колпачками 2 Подключите клапан коллектора с измерителем и вакуумный насос к сервисному порту стопорного клапана на стороне трубы для газа наружного прибора 3 Включите вакуумный насос Продолжайте создавать вакуум в течение не менее 15 минут 4 Проверьте вакуум с помощью клапана коллектора с измерителем затем закройте клапан коллектора с измерителем...

Страница 14: ... переключатель 1 в SW1 на наружной панели управления в положение ON ВКЛ чтобы включить эту функцию 3 Установите переключатель 2 в SW1 на наружной панели управления в положение OFF ВЫКЛ чтобы заблокировать режим работы COOL DRY ОХЛАЖДЕНИЕ СУШКА Чтобы заблокировать режим работы HEAT ОБОГРЕВ установите тот же переключатель в позиции ON ВКЛ 4 Включите электропитание кондиционера Описание функции С дан...

Страница 15: ...атной платы системы электронно го управления обязательно выполните процедуру снятия электростати ческого заряда перед включением данной функции Данная функция не работает при температуре наружного воздуха 0 C или ниже Индикация светодиода во время обнаружения Светодиод 1 Красный 2 Желтый 3 Зеленый Горит Горит Мигает Результат работы функции коррекции труб проводов Светодиод Результат 1 Крас ный 2 ...

Страница 16: ...HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN JG79A366H03 ...

Отзывы: