63
Outdoor model
Indoor units number
Piping total length
Connecting pipe length
Height difference (Indoor ~ Outdoor)
Height difference (Indoor ~ Indoor)
Function
Capacity [Rated (Min.-Max.) Hz]
Dehumidification
Outdoor air flow
Breaker capacity
Running current
Power input
Power factor
Starting current
Compressor motor current
Fan motor current
Model
Output
Winding
resistance(at 20 °C)
Model
Winding
resistance(at 20 °C)
Dimensions W x H x D
Weight
Sound level (High/Low)
Fan speed (High/Low)
Fan speed regulator
Refrigerant filling
capacity(R410A)
Refrigeration oil (Model)
MXZ-2A52VA
Single phase
230 V, 50 Hz
2
Max. 30
Max. 20
Refer to 9
Refer to 9
15
97
7.64
0.2
1,400
U-V 0.64
V-W 0.64 W-U 0.64
RC0J50-CF
BLK-WHT 14.2
WHT-RED 14.2 RED-BLK 14.2
800 x 550 x 285
40
2
1.3
450 (NEO22)
Cooling
5.2 (1.1 - 6.0)
—
1,860
6.75
1,505
6.55
3.46
49/45
850/530
Heating
6.4 (1.0 - 7.2)
—
1,860
7.64
1,705
7.44
3.75
50/48
850/490
U-V 0.45
V-W 0.45 W-U 0.45
U-V 0.98
V-W 0.98 W-U 0.98
m
m
m
m
kW
/h
m
3
/h
A
A
W
%
A
A
A
W
Ω
Ω
mm
kg
dB
rpm
kg
cc
Compressor
2 Electrical
data
Fan
motor
Special
remarks
Capacity
System
Coefficient of performance(C.O.P) 2
Outdoor unit power supply
MXZ-3A54VA
Single phase
230 V, 50 Hz
2 to 3
Max. 50
Max. 25
Refer to 9
Refer to 9
25
99
6.39
0.2
1,400
RC0J60-AA
BLK-WHT 15.2
WHT-RED 15.2 RED-BLK 15.2
840 x 710 x 330
57
2
2.7
600 (NEO22)
700 (NEO22)
Cooling
5.4 (2.9-6.8)
—
2,525
5.69
1,295
5.49
4.17
46/44
650/510
Heating
6.8 (2.6-9.0)
—
2,470
6.39
1,455
6.19
4.67
48/47
640/510
SNB130FLDH1
SNB130FLEH1
SNB130FGBH1
SNB130FGBH1T
SNB130FKCH
SNB130FKMH
E1
E2
E2
E1
E3
E2
E1
E3
E2
E1
E3
,
,
,
,
,
E5
E4
,
E6
,
E7
,
E5
E4
,
E6
,
E7
,
E7
E5
E4
E6
,
,
TEST CONDITIONS COOLING INDOOR
Dry-bulb temperature 27.0°C Wet-bulb temperature 19.0°C
OUTDOOR Dry-bulb temperature 35.0°C Wet-bulb temperature 24.0°C
HEATING INDOOR
Dry-bulb temperature 20.0°C
OUTDOOR Dry-bulb temperature 7.0°C Wet-bulb temperature 6.0°C
NOTE: •Test conditions are based on ISO 5151. (Refrigerant piping length (one way): 5 m)
•Refer to 3 “INDOOR/OUTDOOR CORRESPONDENCE TABLE” for the combination.
1 Measured under rated operating frequency.
2 Electrical data is for only outdoor unit.
3 These specifications are when all indoor units are operating.
Содержание MXZ-2A30VA
Страница 79: ...79 MXZ 3A54VA E7 ...
Страница 83: ...83 MXZ 4A71VA E7 ...