8
The standard specifications apply only to the operation of the air conditioner under normal conditions, since operating condi-
tions vary according to the areas where these units are installed. The following information has been provided to clarify the
operating characteristics of the air conditioner under the conditions indicated by the performance curve.
(1) GUARANTEED VOLTAGE
198~264 V
(2) AIR FLOW
Air flow should be set at MAX.
(3) MAIN READINGS
(1) Indoor intake air wet-bulb temperature:
°CWB
(2) Indoor outlet air wet-bulb temperature:
°CWB
(3) Outdoor intake air dry-bulb temperature:
°CDB
(4)
Total
input:
W
(5) Indoor intake air dry-bulb temperature:
°CDB
(6) Outdoor intake air wet-bulb temperature:
°CWB
(7) Total input:
W
Indoor air wet/dry-bulb temperature difference on the left side of the following chart shows the difference between the
indoor intake air wet/dry-bulb temperature and the indoor outlet air wet/dry-bulb temperature for your reference at service.
}
}
Cooling
Heating (
MUH-GE50VB
)
Length of connecting pipe: m
Indoor unit
Piping size O.D: mm
Liquid
6.35
Gas
12.7
Outdoor unit
Gas 0.43
Liquid 0.5
Gas 0
Liquid 0
Model
MU-GE50VB
MUH-GE50VB
10
25
Refrigerant piping: m
Max. length
A
Max. height
B
Indoor
unit
Max. height
B
Outdoor unit
Refrigerant Piping
Max. length
A
7 m
0
10 m
60
15 m
160
20 m
260
Calculation : Xg = 20 g/m × (A-7)m
25 m
360
MUH-GE50VB
1350
1450
MU-GE50VB
Outdoor unit precharged
Model
Refrigerant piping length (one way)
MAX. HEIGHT DIFFERENCE
ADDITIONAL REFRIGERANT CHARGE (R410A: g)
MAX. REFRIGERANT PIPING LENGTH
PERFORMANCE CURVES
8
MU-GE50VB MUH-GE50VB