18
OPERATING PROCEDURE
PHOTOS
3. Removing the propeller and the outdoor fan motor
(1) Remove the cabinet. (Refer to 1.)
(2) Remove the propeller nut and the propeller.
NOTE : Loose the propeller in the rotating direction for
removal.
When attaching the propeller, align the mark on the
propeller and the motor shaft cut section.
Set the propeller in position by using the cut on the shaft
and the mark on the propeller.
(3) Remove the lead clamps and outdoor fan motor lead wires.
(4) Remove the screws fixing the outdoor fan motor.
(5) Remove the outdoor fan motor.
Photo 4
Propeller
Outdoor fan motor
connector
2. Removing the electrical parts
(1) Remove the service panel and the cabinet.(Refer to 1.)
(2) Remove the following parts.
•Compressor capacitor (C1)
•Outdoor fan capacitor (C2)
•Terminal block (TB1,TB2)
•Surge absorber (DSAR)
•Compressor contactor (52C)
Photo 3
Surge absorber (DSAR)
Outdoor fan
capacitor (C2)
Compressor contactor (52C)
Compressor capacitor (C1)
Terminal block (TB2)
Terminal
block
(TB1)
Screws of the
outdoor fan motor
Sound proof felt
Conduit
plate
OB449A.qxp 06.5.9 11:14 AM Page 18