16
WIRELESS REMOTE CONTROLLER
MICROPROCESSOR CONTROL
9
NOTE
: Last setting will be stored after the unit is turned OFF with the remote controller. Indoor unit receives the signal of the
remote controller with beeps.
Signal transmitting section
Operation display section
TEMPERATURE buttons
STOP/OPERATE
(OFF/ON) button
Indication of
remote controller
model is on back
Distance of signal : About 6 m
Beep(s) is (are) heard from
the indoor unit when the
signal is received.
FAN SPEED CONTROL button
PURIFIER button
DIRECTION button
OPERATION SELECT button
ECONO COOL button
POWERFUL button
CLOCK button
Lid
Slide the lid down
to open the remote
controller. Slide it down
further to get to the
weekly timer buttons.
WEEKLY TIMER
set buttons
TIME, TIMER set buttons
FORWARD button
BACKWARD button
RESET button
i-save button
NIGHT MODE button
SENSOR (i-see) button
VANE CONTROL button
WIDE VANE button
INDOOR UNIT DISPLAY SECTION
Operation Indicator lamp
The operation indicator at the right side of the indoor unit indicates the operation state.
•The following indication applies regardless of shape of the indication.
Indication
Operation state
Room temperature
Standby mode
(Only during multi system
operation)
-
Lit
Blinking
Not lit
MSZ-LN18VGW
MSZ-LN25VGW
MSZ-LN35VGW
MSZ-LN50VGW
MSZ-LN60VGW
MSZ-LN18VGV
MSZ-LN25VGV
MSZ-LN35VGV
MSZ-LN50VGV
MSZ-LN60VGV
MSZ-LN18VGB
MSZ-LN25VGB
MSZ-LN35VGB
MSZ-LN50VGB
MSZ-LN60VGB
MSZ-LN18VGR
MSZ-LN25VGR
MSZ-LN35VGR
MSZ-LN50VGR
MSZ-LN60VGR
MSZ-LN18VG2W
-
E1
,
ET1
MSZ-LN25VG2W
-
E1
,
ET1
MSZ-LN35VG2W
-
E1
,
ET1
MSZ-LN50VG2W
-
E1
,
ET1
MSZ-LN60VG2W
MSZ-LN18VG2V
-
E1
,
ET1
MSZ-LN25VG2V
-
E1
,
ET1
MSZ-LN35VG2V
-
E1
,
ET1
MSZ-LN50VG2V
-
E1
,
ET1
MSZ-LN60VG2V
MSZ-LN18VG2B
-
E1
,
ET1
MSZ-LN25VG2B
-
E1
,
ET1
MSZ-LN35VG2B
-
E1
,
ET1
MSZ-LN50VG2B
-
E1
,
ET1
MSZ-LN60VG2B
MSZ-LN18VG2R
-
E1
,
ET1
MSZ-LN25VG2R
-
E1
,
ET1
MSZ-LN35VG2R
-
E1
,
ET1
MSZ-LN50VG2R
-
E1
,
ET1
MSZ-LN60VG2R
8-6. CHANGING THE CORRECTION VALUE OF THE ROOM TEMPERATURE
Cut the jumper wire JR24 when the room temperature does not reach the set temperature during heating opera-
tion. (Refer to 10-7.)
Cutting the jumper wire JR24 changes the correction value of the room temperature during heating operation from
-2
°C
to -5
°C
and lets the AUTO fan speed of the indoor unit and the compressor frequency increase easily.
The applicable models are MSZ-LN**VG2W, MSZ-LN**VG2V, MSZ-LN**VG2B, and MSZ-LN**VG2R.
JR24
CN1J1
CN151
INDOOR electronic control
P.C. board
CN102
OBH766C