(2) OPERATION
Mode
Condition
Intake air temperature (°F)
Indoor
Outdoor
DB
WB
DB
WB
Cooling
Standard temperature
80
67
95
—
Maximum temperature
90
73
115
—
Minimum temperature
67
57
14
—
Maximum humidity
78%
—
Heating
Standard temperature
70
60
47
43
Maximum temperature
80
67
75
65
Minimum temperature
70
60
-4
-5
3-1. OPERATING RANGE
(1) POWER SUPPLY
Rated voltage
Guaranteed voltage (V)
Indoor unit
115 V
1 phase
60 Hz
Min. 103
115
Max. 127
3-2. OUTLET AIR SPEED AND COVERAGE
●
The air coverage is the figure up to the
position where the air speed is 1 ft./s.,
when air is blown out horizontally from
the unit properly at the High speed posi-
tion.
The coverage should be used only as a
general guideline since it varies accord-
ing to the size of the room and furniture
arranged inside the room.
Model
Mode
Function
Air
fl
ow
(CFM)
Air speed
(ft./s.)
Coverage
(ft.)
MSZ-JP09WA
HEAT
Dry
406
20.6
29.5
COOL
Dry
399
20.2
29.0
Wet
364
18.4
26.5
MSZ-JP12WA
HEAT
Dry
406
20.6
29.5
COOL
Dry
399
20.2
29.0
Wet
364
18.4
26.5