9
MSZ-HJ25VA MSZ-HJ35VA MSZ-HJ50VA
Unit : mm
5
OUTLINES AND DIMENSIONS
232
5
69
41
799
785
7
290
120
630
49
57
80
42
43
69
57
42
7
103
130
100
(57°)
225
225
80.5
80.5
61.5
59.5
340
338
41
42
249
248
21.5
3
167
157
207.5
206.5
172
14
140
57
18
46
Air in
Installation plate
Piping
Drain hose
Air out
11×26 Oblong hole
11×20 Oblong hole
Installation plate
Indoor unit
Wall hole Ø65
Piping
Insulation
Ø35 O.D
Liquid line
Ø7 - 0.39m (Flared connection Ø6.35)
Gas line
Ø9.52 - 0.34m (Flared connection Ø9.52)
Drain hose
Insulation Connected part Ø16 O.D active length 370
MSZ-HJ25/35VA
MSZ-HJ50VA
Piping
Insulation
Ø37 O.D
Liquid line
Ø7 - 0.39m (Flared connection Ø6.35)
Gas line
Ø9.52 - 0.34m (Flared connection Ø12.7)
Drain hose
InsulationØ28 Connected part Ø16 O.D active length 370
Piping
Insulation
Ø50 O.D
Liquid line
Ø8 - 0.39m (Flared connection Ø6.35)
Gas line
Ø12 - 0.34m (Flared connection Ø15.88)
Drain hose
Insulation Connected part Ø16 O.D
MSZ-HJ60VA
MSZ-HJ71VA
Piping
Insulation
Ø50 O.D
Liquid line
Ø8 - 0.39m (Flared connection Ø9.52)
Gas line
Ø12 - 0.34m (Flared connection Ø15.88)
Drain hose
Insulation Connected part Ø16 O.D
MSZ-HJ60VA MSZ-HJ71VA
OBH647D
Содержание MSZ-HJ25VA
Страница 11: ...11 MSZ HJ60VA E1 ER1 MSZ HJ71VA E1 ER1 MSZ HJ60VA E2 MSZ HJ71VA E2 OBH647D ...
Страница 43: ...43 ...