21
9-5. TROUBLE CRITERION OF MAIN PARTS
MSZ-HE09NA MSZ-HE12NA MSZ-HE15NA MSZ-HE18NA MSZ-HE24NA
Part name
Check method and criterion
Figure
Room temperature
thermistor (RT11)
Indoor coil thermistor
(RT12, RT13)
Measure the resistance with a tester.
Refer to 9-7. "Test point diagram and voltage", 2 or 3. "Indoor electronic
control P.C. board", for the chart of thermistor.
Indoor fan motor (MF)
Check 9-6.
MSZ-HE09/12/15/18NA
Vane motor (MV)
Measure the resistance between the terminals with a tester.
(Temperature: 50 - 86°F (10 - 30°C))
Color of the lead wire
Normal
RED - BLK
223 - 268
Ω
MSZ-HE24NA
Horizontal vane motor
(MV)
Measure the resistance between the terminals with a tester.
(Part temperature 50 ~ 86°F (10 ~ 30°C))
Color of the lead wire
Normal
Horizontal vane motor (MV)
RED-BLK
313 ~ 375
Ω
BLK
BLK
RED
BLK
BLK
ROTOR
BLK
BLK
RED
BLK
BLK
ROTOR
ROTOR
OBH685