background image

SPLIT-TYPE AIR CONDITIONERS

INDOOR UNIT

MSZ-GL25VGD   MSZ-GL35VGD   MSZ-GL42VGD
MSZ-GL50VGD   MSZ-GL60VGD   MSZ-GL71VGD   MSZ-GL80VGD

English

OPERATING INSTRUCTIONS

 

For user

•  To  use  this  unit  correctly  and  safely,  be  sure  to  read  these  operating 

 

instructions before use.

JG79A991H01_Cover.indd   1

2015/04/08   14:55:04

Содержание MSZ-GL25VGD

Страница 1: ...INDOOR UNIT MSZ GL25VGD MSZ GL35VGD MSZ GL42VGD MSZ GL50VGD MSZ GL60VGD MSZ GL71VGD MSZ GL80VGD English OPERATING INSTRUCTIONS For user To use this unit correctly and safely be sure to read these operating instructions before use ...

Страница 2: ... outlet This may cause overheating fire or electric shock Make sure the power plug is free of dirt and insert it securely into the outlet A dirty plug may cause fire or electric shock Do not bundle pull damage or modify the power cord and do not apply heat or place heavy objects on it This may cause fire or electric shock Do not turn the breaker OFF ON or disconnect connect the power plug during oper...

Страница 3: ...nit wetting and damaging the furniture In case of an abnormal condition Immediately stop operating the air conditioner and consult your dealer CAUTION Replace all batteries of the remote controller with new ones of the same type Using an old battery together with a new one may cause overheat ing leakage or explosion If the battery fluid comes in contact with your skin or clothes wash them thoroughl...

Страница 4: ...rol button Page 6 TIME TIMER set but tons Pages 4 8 Increase time Decrease time CLOCK button Page 4 RESET button Page 4 Lid Slide the lid down to open the remote controller Slide it down further to get to the weekly timer buttons Install the remote controller holder in a place where the signal can be received by the indoor unit When the remote controller is not used place it in this holder Only us...

Страница 5: ...eries with expired shelf lives last shorter Press RESET gently using a thin instrument If the RESET button is not pressed the remote controller may not operate correctly Before operation Insert the power supply plug into the power outlet and or turn the breaker on Installing the remote controller batteries PREPARATION BEFORE OPERATION 1 Remove the front lid 2 Insert the negative pole of AAA alkali...

Страница 6: ... pressed the operation changes in the following order 1 Press to start the operation 2 Press to select operation mode Each press changes mode in the following order 3 Press or to set the temperature Each press raises or lowers the temperature by 1 C Press to stop the operation The same setting is selected the next time by simply pressing Auto restart function If a power failure occurs or the main ...

Страница 7: ...ng Swing The vane moves up and down intermittently AUTO Quiet Low Med High Super High GL71 80 GL25 35 42 50 60 Press to select fan speed Each press changes fan speed in the following order Two short beeps are heard from the indoor unit when set to AUTO Use higher fan speed to cool heat the room more powerfully It is rec ommended to lower the fan speed once the room is cool warm Use lower fan speed...

Страница 8: ... weekly timer Example of use 1 Low energy mode Set the temperature 2 C to 3 C warmer in COOL and cooler in HEAT mode This setting is suitable for unoccupied room and while you are sleeping 2 Saving frequently used settings Save your preferred setting for COOL ECONO COOL and HEAT This ena bles you to select your preferred setting with a single push of the button LONG OPERATION Press to start LONG o...

Страница 9: ... cessor It is possible to perform cooling operation with keeping comfort As a result energy can be saved 1 Press or during operation to set the timer ON timer The unit turns ON at the set time OFF timer The unit turns OFF at the set time or blinks Make sure that the current time and day are set correctly Page 4 2 Press Increase and Decrease to set the time of timer Each press increases or decrease...

Страница 10: ...setting mode and press and hold for 5 seconds to erase all weekly timer settings Point the remote controller toward the indoor unit 5 Press to turn the weekly timer ON lights When the weekly timer is ON the day of the week whose timer setting is complete will light Press again to turn the weekly timer OFF goes out Note The saved settings will not be cleared when the weekly timer is turned OFF Chec...

Страница 11: ...he air conditioner continues to perform cooling or heating operation during the demand response event but the elec trical energy consumed by the air conditioner in a half hour period is not more than 50 of the total electrical energy that would be consumed if operating at the rated capacity in a half hour period DRM 3 The air conditioner continues to perform cooling or heating operation during the...

Страница 12: ...install all tabs of the air filter When dirt cannot be removed by vacuum cleaning Soak the filter and its frame in lukewarm water before rinsing it Diluted mild detergents can be used when dirt cannot be removed After washing with water dry it well in shade Install all tabs of the air filter Every year Replace it with a new air cleaning filter for best performance Parts Number GL25 35 42 50 60 MAC 408...

Страница 13: ...kes ice forming on the outdoor unit melt and drip down White smoke is discharged from the outdoor unit In the heating operation vapor generated by the defrosting operation looks like white smoke Symptom Explanation Check points Remote controller The display on the remote controller does not appear or it is dim The indoor unit does not respond to the remote control signal Are the batteries exhauste...

Страница 14: ...r trips frequently The remote control signal is not received in a room where an electronic ON OFF type fluorescent lamp inverter type fluorescent lamp etc is used Operation of the air conditioner interferes with radio or TV reception An ampli fier may be required for the affected device When an abnormal sound is heard When any refrigerant leakage is found OPERATING INSTRUCTIONS WHEN YOU THINK THAT TR...

Страница 15: ...ncy and to extend the life time of using the outdoor unit should be installed in well ventilated dry place TV Cordless phone or Portable phone 3 m or more 1 m or more The installation location of the outdoor unit should be at least 3 m away from the antennas for TV sets radios etc In areas where the reception is weak provide greater space between the outdoor unit and the antenna of the affected de...

Страница 16: ...JG79A991H01 HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN ...