Mitsubishi Electric MSZ-GE60VAD Скачать руководство пользователя страница 4

En-

● OPERATING INSTRUCTIONS ●

•   Make sure the polarity of the batteries is correct.

•   Do not use manganese batteries and leaking batteries. The remote controller 

could malfunction.

•   Do not use rechargeable batteries.

•   Replace all batteries with new ones of the same type.

•  Batteries can be used for approximately 1 year. However, batteries with 

expired shelf lives last shorter.

•  Press RESET gently using a thin instrument.

  If the RESET button is not pressed, the remote controller may not operate 

correctly.

Before operation:

 Insert the power supply plug into the power outlet and/or turn the breaker on.

•  Press CLOCk gently using a thin instrument.

Operation indicator lamp

Remote control receiving section

Emergency  

operation switch 

 Page 4 

Air inlet (back and side)

Refrigerant piping

Drainage hose

Air outlet

Drain outlet

Horizontal vane

vertical vane

Air outlet

Fan

Air filter 

(Nano platinum filter)

Air inlet

Heat exchanger

Front panel

Outdoor unit

Installing the remote controller batteries

Setting current time

N

AME OF EACH PART

P

REPARATION BEFORE OPERATION

1.

 Press CLOCk.

4.

 Press CLOCk again.

2.

 Press either the TIME button or 

the TIMER buttons to set the 

time.

 

Each press increases/decreases 

the time by 1 minute (10 minutes 

when pressed longer).

Indoor unit

Remote controller

Outdoor units may be different in appearance.

1.

 Remove the front lid.

2.

 Insert the negative 

pole of AAA alkaline 

batteries first.

3.

 Install the front lid.

4.

 Press RESET.

Air cleaning filter 

(Electrostatic anti-allergy 

enzyme filter)

Remote controller holder

Signal transmitting 

section

Distance of signal : 

About 6 m

Beep(s) is (are) heard 

from the indoor unit 

when the signal is 

received.

Operation  

display section

ON/OFF 

(operate/stop) button

Temperature 

buttons 

 Page 4 

Operation 

select button  

 Page 4 

ECONO COOL  

button 

 Page 6 

FAN speed control 

button 

 Page 5 

LONG button 

 Page 5 

WIDE vANE control 

button 

 Page 5 

vANE control button 

 Page 5 

TIME, TIMER set but-

tons  

 Pages 3, 6 

  Increase time

  Decrease time

CLOCk button 

 Page 3 

RESET button 

 Page 3 

Lid

Slide the lid down to open 

the remote controller. Slide 

it down further to get to the 

weekly timer buttons.

•  Install the remote 

controller holder in a 

place where the signal 

can be received by the 

indoor unit.

•   When the remote 

controller is not used, 

place it in this holder.

Only use the remote controller provided 

with the unit.

Do not use other remote controllers.

If two or more indoor units are installed 

in proximity to one another, an indoor 

unit that is not intended to be operated 

may respond to the remote controller.

Display section

3.

 Press the DAY button 

to set the day.

POWERFUL 

button 

 Page 5 

i-save button  

 Page 6 

WEEkLY TIMER

set buttons 

 Page 7 

Fan guard

JG79A789H01_en.indd   3

2013/07/18   11:12:42

Содержание MSZ-GE60VAD

Страница 1: ...α βεβαι ωθείτε ότι έχετε διαβάσει αυτό το εγχειρίδιο οδηγιών πριν από τη χρή ση LIBRETTO D ISTRUZIONI Per gli utenti Per utilizzare correttamente ed in tutta sicurezza questo apparecchio leggere il presente libretto d istruzioni prima dell uso MANUAL DE INSTRUCCIONES Para los clientes Para utilizar esta unidad de forma correcta y segura lea previamente estas instrucciones de funcionamiento BEDIENI...

Страница 2: ...ly to cool air for a prolonged length of time This could be detrimental to your health The unit should not be installed relocated disassembled altered or repaired by the user An improperly handled air conditioner may cause fire electric shock injury or water leakage etc Consult your dealer If the power supply cord is damaged it must be replaced by the manufacturer or its service agent in order to ...

Страница 3: ... and immediately seek medical atten tion Ensure that the area is well ventilated when the unit is operated together with a combustion appliance Inadequate ventilation may cause oxygen starvation Turn the breaker OFF when you hear thunder and there is a pos sibility of a lightning strike The unit may be damaged if lightning strikes WARNING Consult your dealer for installing the air conditioner It s...

Страница 4: ...er Indoor unit Remote controller Outdoor units may be different in appearance 1 Remove the front lid 2 Insert the negative pole of AAA alkaline batteries first 3 Install the front lid 4 Press RESET Air cleaning filter Electrostatic anti allergy enzyme filter Remote controller holder Signal transmitting section Distance of signal About 6 m Beep s is are heard from the indoor unit when the signal is...

Страница 5: ... in the following order 3 Press or to set the temperature Each press raises or lowers the temperature by 1 C Press to stop the operation The same setting is selected the next time by simply pressing Auto restart function If a power failure occurs or the main power is turned off during operation Auto restart function automatically starts operation in the same mode as the one set with the remote con...

Страница 6: ...on COOL DRY horizontal position HEAT position 5 Manual For efficient air conditioning select the upper position for COOL DRY and the lower position for HEAT If the lower position is selected during COOL DRY the vane automatically moves to the horizontal position after 0 5 to 1 hour to prevent any condensation from dripping Swing The vane moves up and down intermittently AUTO Silent Low Med High Su...

Страница 7: ...setting with a single push of the button Note When using the multi system MXZ 8A140 the temperature cannot be set to 10 C Even if the temperature is set to 10 C the air conditioner will operate at 16 C ECONO COOL OPERATION Press during COOL mode page 4 to start ECONO COOL operation The unit performs swing operation vertically in various cycles according to the temperature of airflow Press again to...

Страница 8: ...kly timer settings will be saved Press to enter the weekly timer setting mode and press and hold for 5 seconds to erase all weekly timer settings Point the remote controller toward the indoor unit 5 Press to turn the weekly timer ON lights When the weekly timer is ON the day of the week whose timer setting is complete will light Press again to turn the weekly timer OFF goes out Note The saved sett...

Страница 9: ...ticles are incorporated into the filter material which results in pro viding semi permanent antibacterial and deodorizing characteristics for the filter Nano platinum surpasses the catechin a bioflavonoid that is found in green tea in performance Nano platinum filter uses this compound not only to improve air quality but also to eliminate bacteria and viruses This air filter has a semi permanent l...

Страница 10: ...During COOL and DRY operations pipe or pipe connecting sections are cooled and this causes water to condense In the heating operation water condensed on the heat exchanger drips down In the heating operation the defrosting operation makes ice forming on the outdoor unit melt and drip down White smoke is discharged from the outdoor unit In the heating operation vapor generated by the defrosting ope...

Страница 11: ...e or Portable phone 3 m or more 1 m or more The installation location of the outdoor unit should be at least 3 m away from the antennas for TV sets radios etc In areas where the reception is weak provide greater space between the outdoor unit and the antenna of the affected device if operation of the air conditioner interferes with radio or TV reception 1 Set to the highest temperature in manual C...

Страница 12: ...HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN JG79A789H01 ...

Отзывы: