background image

Русский

Türkçe

Svenska

Dansk

Português

Ελληνικά

Italiano

Español

Nederlands

Français

Deutsch

ИНСТРУКЦИИ ПО ЭКСПЛУАТАЦИИ 

Для пользователя

•  В  целях  правильной  и  безопасной  эксплуатации  данного  устройс

-

тва  обязательно  перед  его  использованием  прочтите  настоящее 

руководство по эксплуатации.

ÇALIŞTIRMA TALİMATLARI 

Kullanıcı için

•  Bu  üniteyi  doğru  ve  güvenli  bir  biçimde  kullanmak  için,  kullanmadan 

önce bu işletim talimatlarını okuduğunuzdan emin olun.

BRUKSANVISNING 

För användaren

•  Läs bruksanvisningen innan enheten tas i bruk så att den används sä

-

kert och på rätt sätt.

BETJENINGSVEJLEDNING 

Til kunden

•  Læs denne betjeningsvejledningen før brug, så enheden bruges korrekt 

og sikkert.

INSTRUÇÕES DE OPERAÇÃO 

Para o utilizador

•  Para utilizar esta unidade correctamente e com segurança, certifique-

se de que lê estas instruções de operação antes da utilização.

ΟΔΗΓΙΕΣ ΛΕΙΤΟΥΡΓΙΑΣ 

Για το χρήστη

•  Για να χρησιμοποιήσετε αυτή τη μονάδα σωστά και με ασφάλεια, βεβαι

-

ωθείτε ότι έχετε διαβάσει αυτό το εγχειρίδιο οδηγιών πριν από τη χρή

-

ση.

LIBRETTO D’ISTRUZIONI 

Per gli utenti

•  Per  utilizzare  correttamente  ed  in  tutta  sicurezza  questo  apparecchio, 

leggere il presente libretto d’istruzioni prima dell’uso.

MANUAL DE INSTRUCCIONES 

Para los clientes

•  Para utilizar esta unidad de forma correcta y segura, lea previamente 

estas instrucciones de funcionamiento.

BEDIENINGSINSTRUCTIES 

Voor de klant

•  Om dit apparaat correct en veilig te kunnen gebruiken moet u deze be

-

dieningsinstructies voor gebruik eerst doorlezen.

NOTICE D’UTILISATION 

A l’attention des clients

•  Pour  avoir  la  certitude  d’utiliser  cet  appareil  correctement  et  en  toute 

sécurité, veuillez lire cette notice d’instructions avant de mettre le clima

-

tiseur sous tension.

BEDIENUNGSANLEITUNG

 

For den Anwender

•  Für einen sicheren und ordnungsgemäßen Gebrauch des Geräts unbe

-

dingt diese Bedienungsanleitung vor der Inbetriebnahme durchlesen.

SPLIT-TYPE AIR CONDITIONERS

INDOOR UNIT

MSZ-GE60VAD   MSZ-GE71VAD   MSZ-GE80VAD

English

OPERATING INSTRUCTIONS

 

For user

•  To use this unit correctly and safely, be sure to read these operating in

-

structions before use.

JG79A789H01_Cover.indd   1

2013/07/01   10:35:02

Содержание MSZ-GE60VAD

Страница 1: ...α βεβαι ωθείτε ότι έχετε διαβάσει αυτό το εγχειρίδιο οδηγιών πριν από τη χρή ση LIBRETTO D ISTRUZIONI Per gli utenti Per utilizzare correttamente ed in tutta sicurezza questo apparecchio leggere il presente libretto d istruzioni prima dell uso MANUAL DE INSTRUCCIONES Para los clientes Para utilizar esta unidad de forma correcta y segura lea previamente estas instrucciones de funcionamiento BEDIENI...

Страница 2: ...ly to cool air for a prolonged length of time This could be detrimental to your health The unit should not be installed relocated disassembled altered or repaired by the user An improperly handled air conditioner may cause fire electric shock injury or water leakage etc Consult your dealer If the power supply cord is damaged it must be replaced by the manufacturer or its service agent in order to ...

Страница 3: ... and immediately seek medical atten tion Ensure that the area is well ventilated when the unit is operated together with a combustion appliance Inadequate ventilation may cause oxygen starvation Turn the breaker OFF when you hear thunder and there is a pos sibility of a lightning strike The unit may be damaged if lightning strikes WARNING Consult your dealer for installing the air conditioner It s...

Страница 4: ...er Indoor unit Remote controller Outdoor units may be different in appearance 1 Remove the front lid 2 Insert the negative pole of AAA alkaline batteries first 3 Install the front lid 4 Press RESET Air cleaning filter Electrostatic anti allergy enzyme filter Remote controller holder Signal transmitting section Distance of signal About 6 m Beep s is are heard from the indoor unit when the signal is...

Страница 5: ... in the following order 3 Press or to set the temperature Each press raises or lowers the temperature by 1 C Press to stop the operation The same setting is selected the next time by simply pressing Auto restart function If a power failure occurs or the main power is turned off during operation Auto restart function automatically starts operation in the same mode as the one set with the remote con...

Страница 6: ...on COOL DRY horizontal position HEAT position 5 Manual For efficient air conditioning select the upper position for COOL DRY and the lower position for HEAT If the lower position is selected during COOL DRY the vane automatically moves to the horizontal position after 0 5 to 1 hour to prevent any condensation from dripping Swing The vane moves up and down intermittently AUTO Silent Low Med High Su...

Страница 7: ...setting with a single push of the button Note When using the multi system MXZ 8A140 the temperature cannot be set to 10 C Even if the temperature is set to 10 C the air conditioner will operate at 16 C ECONO COOL OPERATION Press during COOL mode page 4 to start ECONO COOL operation The unit performs swing operation vertically in various cycles according to the temperature of airflow Press again to...

Страница 8: ...kly timer settings will be saved Press to enter the weekly timer setting mode and press and hold for 5 seconds to erase all weekly timer settings Point the remote controller toward the indoor unit 5 Press to turn the weekly timer ON lights When the weekly timer is ON the day of the week whose timer setting is complete will light Press again to turn the weekly timer OFF goes out Note The saved sett...

Страница 9: ...ticles are incorporated into the filter material which results in pro viding semi permanent antibacterial and deodorizing characteristics for the filter Nano platinum surpasses the catechin a bioflavonoid that is found in green tea in performance Nano platinum filter uses this compound not only to improve air quality but also to eliminate bacteria and viruses This air filter has a semi permanent l...

Страница 10: ...During COOL and DRY operations pipe or pipe connecting sections are cooled and this causes water to condense In the heating operation water condensed on the heat exchanger drips down In the heating operation the defrosting operation makes ice forming on the outdoor unit melt and drip down White smoke is discharged from the outdoor unit In the heating operation vapor generated by the defrosting ope...

Страница 11: ...e or Portable phone 3 m or more 1 m or more The installation location of the outdoor unit should be at least 3 m away from the antennas for TV sets radios etc In areas where the reception is weak provide greater space between the outdoor unit and the antenna of the affected device if operation of the air conditioner interferes with radio or TV reception 1 Set to the highest temperature in manual C...

Страница 12: ...HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN JG79A789H01 ...

Отзывы: