 AUTO mode (Auto change over)

The unit selects the operation mode according to the difference between the 

room temperature and the set temperature. During AUTO mode, the unit 

changes mode (COOL↔HEAT) when the room temperature is about 2°C 

away from the set temperature for more than 15 minutes.

Note: 

Auto Mode is not recommended if this indoor unit is connected to a MXZ 

type outdoor unit. When several indoor units are operated simultaneously, 

the unit may not be able to switch operation mode between COOL and 

HEAT. In this case, the indoor unit becomes standby mode (Refer to table 

of Operation indicator lamp).

 COOL mode

Enjoy cool air at your desired temperature. 

Note: 

Do  not  operate  COOL  mode  at  very  low  outside  temperatures  (less  than 

-10°C). Water condensed in the unit may drip and wet or damage furniture, etc.

  DRY mode

Dehumidify your room. The room may be cooled slightly. 

Temperature cannot be set during DRY mode.

 HEAT mode

Enjoy warm air at your desired temperature.

1

Press 

 to start the operation.

2

Press 

 to select operation mode. Each press 

changes mode in the following order:

3

Press 

 or 

 to set the temperature.

Each press raises or lowers the temperature by 1°C.

 

Press 

 to stop the operation.

S

ELECTING OPERATION MODES

Note:

Multi system operation

Two or more indoor units can be operated by one outdoor unit. When several 

indoor units are operated simultaneously, cooling and heating operations can-

not be done at the same time. When COOL is selected with one unit and HEAT 

with another or vice versa, the unit selected last goes into standby mode.

Auto restart function

If a power failure occurs or the main power is turned off during operation, “Auto 

restart function” automatically starts operation in the same mode as the one set 

with the remote controller just before the shutoff of the main power. When timer is 

set, timer setting is cancelled and the unit starts operation when power is resumed.

If you do not want to use this function, please consult the service repre-

sentative because the setting of the unit needs to be changed.

(AUTO) 

(COOL) 

(DRY) 

(HEAT)

Operation indicator lamp

Emergency operation

When the remote controller cannot be used...

Emergency operation can be activated by pressing the emergency operation 

switch (E.O.SW) on the indoor unit.

Each time the E.O.SW is pressed, the operation changes in 

the following order:

Set temperature : 24°C

Fan speed : Medium

Horizontal vane : Auto

Emergency COOL

Emergency HEAT

Stop

Note:

The  fi rst  30  minutes  of  operation  is  test  run.  Temperature 

control does not work, and fan speed is set to High.

Operation indicator lamp

The operation indicator lamp shows the operation state of the unit.

Indication

Operation state

Room temperature

The unit is operating to reach the set 

temperature

About 2°C or more  

away from set tem-

perature

The room temperature is approach-

ing the set temperature

About 1 to 2°C from 

set temperature

Standby  mode  (only  during  multi 

system operation)

  Lighted 

  Blinking 

  Not lighted

JG79Y158H01_en.indd   4

2016/06/13   17:44:29

Содержание MSZ-GE22VAD2

Страница 1: ...SZ GE22VAD2 MSZ GE25VAD2 MSZ GE35VAD2 MSZ GE42VAD2 MSZ GE50VAD2 English OPERATING INSTRUCTIONS For user To use this unit correctly and safely be sure to read these operating in structions before use JG79Y158H01_Cover indd 1 2016 04 12 14 10 07 ...

Страница 2: ...t must be replaced by the manufacturer or its service agent in order to avoid a hazard When installing relocating or servicing the unit make sure that no substance other than the specified refrigerant R410A enters the refrigerant circuit Any presence of foreign substance such as air can cause abnor mal pressure rise and may result in explosion or injury The use of any refrigerant other than that sp...

Страница 3: ...th clean water and immediately seek medical attention Ensure that the area is well ventilated when the unit is oper ated together with a combustion appliance Inadequate ventilation may cause oxygen starvation Turn the breaker OFF when you hear thunder and there is a possibility of a lightning strike The unit may be damaged if lightning strikes After the air conditioner is used for several seasons ...

Страница 4: ...r holder Signal transmitting section Distance of signal About 6 m Beep s is are heard from the indoor unit when the signal is received Operation display section OFF ON stop operate button Temperature buttons Page 4 Operation select button Page 4 ECONO COOL button Page 7 FAN speed control button Page 5 VANE control button Page 5 TIME TIMER set buttons Pages 3 6 Increase time Decrease time CLOCK but...

Страница 5: ...ations can not be done at the same time When COOL is selected with one unit and HEAT with another or vice versa the unit selected last goes into standby mode Auto restart function If a power failure occurs or the main power is turned off during operation Auto restart function automatically starts operation in the same mode as the one set with the remote controller just before the shutoff of the ma...

Страница 6: ...atically moves to the upward position after 0 5 to 1 hour to prevent any condensation from dripping Swing The vane moves up and down intermittently To change the horizontal airflow direction Move the vertical vane manually before starting operation WEEKLY TIMER OPERATION A maximum of 4 ON or OFF timers can be set for individual days of the week A maximum of 28 ON or OFF timers can be set for a week...

Страница 7: ...k whose timer setting is complete will light The beep sound is not heard from the indoor unit Press again to turn the weekly timer OFF goes out Note The saved settings will not be cleared when the weekly timer is turned OFF 6 Put the remote controller in places where its signal always reaches the indoor unit which was blink ing goes out and the current time will be displayed E g ON 6 00 and 24 C a...

Страница 8: ...etting in an instance i save operation cannot be set on the weekly timer Example of use 1 Low energy mode Set the temperature 2 C to 3 C warmer in COOL and cooler in HEAT mode This setting is suitable for unoccupied room and while you are sleeping 2 Saving frequently used settings Save your preferred setting for COOL ECONO COOL and HEAT This ena bles you to select your preferred setting with a sin...

Страница 9: ... Anti Allergy Enzyme Filter option Back side of air filter Every 3 months Remove dirt by a vacuum cleaner When dirt cannot be removed by vacuum cleaning Soak the filter and its frame in lukewarm water before rinsing it After washing dry it well in shade Install all tabs of air filter Every year Replace it with a new air cleaning filter for best performance Parts Number MAC 408FT E What is Catechin air...

Страница 10: ...is low during cooling operation the fan operates intermit tently to maintain sufficient cooling capacity Water leaks from the outdoor unit During COOL and DRY operations pipe or pipe connecting sections are cooled and this causes water to condense In the heating operation water condensed on the heat exchanger drips down In the heating operation the defrosting op eration makes water frozen on the ou...

Страница 11: ... space between the outdoor unit and the antenna of the affected device if operation of the air conditioner inter feres with radio or TV reception 1 Operate by COOL mode with the highest temperature set or FAN mode for 3 to 4 hours Page 4 This dries the inside of the unit Moisture in the air conditioner contributes to favorable conditions for growth of fungi such as mold 2 Press to stop the operati...

Страница 12: ...HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN JG79Y158H01 JG79Y158H01_Cover indd 2 2016 04 12 14 10 07 ...

Отзывы: