background image

9

WHEN THE AIR CONDITIONER IS NOT GOING TO BE
USED FOR A LONG TIME

When it is not going to be used for a long
time:

1

Perform the FAN operation for 3 or 4 hours
to dry the inside of the air conditioner.

To perform FAN operation, set the remote controller
to the highest temperature in the MANUAL COOL
mode. (Refer to page 7.)

2

Turn off the breaker and/or disconnect the
power supply plug.

 CAUTION:

Turn off the breaker or disconnect the power supply plug
when the air conditioner is not going to be used for a
long time.
Dirt may collect and this may cause a fire.

3

Remove the batteries from the remote con-
troller.

 CAUTION:

To prevent liquid leakage, take out all batteries when the
remote controller is not going to be used for a long time.

When the air conditioner is to be used
again:

1

Clean the air filter and install it in the indoor
unit.

(Refer to page 10 for cleaning instructions.)

2

Check that the air inlet and outlet of the in-
door/outdoor units are not blocked with any
obstacles.

3

Check that the earth is connected correctly.

  CAUTION:

Earth the unit.
Do not connect the earth to a gas pipe, water pipe,
lightning rod or the earth of a telephone. If the earthing
is incorrect, it may cause an electric shock.

ECONO COOL OPERATION

Use this operation when you want to be comfortable in COOL mode even with energy saved.

TIMER OPERATION (ON/OFF TIMER)

It is convenient to set the timer when you go to bed, when you get home, when you get up, etc.

Perform the following operations while the unit is operating
in the MANUAL COOL mode.

Press the           button.

When the   (ECONO COOL) operation is selected in COOL mode, the air
conditioner performs swing operation vertically in various cycle according to
the temperature of air conditioner.
Also SET TEMPERATURE is automatically set 2°C higher than in COOL mode.

To release the ECONO COOL operation:

Press the           button again.

○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

When the            button is pressed or the operation mode is changed during
the ECONO COOL operation, ECONO COOL operation is released.

The 

FAN

 button, the 

TOO

WARM

 or 

TOO

COOL

 button and ON/OFF timer (explained below)

are available.

What is “ECONO COOL”?

Swing air flow (change of air flow) makes you feel cooler than constant air flow. So, even though the set temperature is
automatically set 2°C higher, it is possible to perform cooling operation with keeping comfort. As a result, energy can be saved.

How to set the ON timer

1

Press the          button during operation.

Each time the button is pressed, the ON timer mode
alternates between ON and OFF.

2

Set the time of the timer using the TIME but-
tons 

 (Forward) and 

 (Backward).

Each time the 

 button is pressed, the set time in-

creases by 10 minutes; each time the 

 button is

pressed, the set time decreases by 10 minutes.

To release the ON timer:

Press the          button.

How to set the OFF timer

1

Press the          button during operation.

Each time the button is pressed, the OFF timer mode
alternates between ON and OFF.

2

Set the time of the timer using the TIME but-
tons 

 (Forward) and 

  (Backward).

Each time the 

 button is pressed, the set time in-

creases by 10 minutes; each time the 

 button is

pressed, the set time decreases by 10 minutes.

To release the OFF timer:

Press the          button.

Programming timer operation

The ON timer and the OFF timer can be used in combination. The timer of the set time that is reached first will operate first.
(“

    

” mark indicates the order of timer operations.)

• If the current time has not been set, the timer operation cannot be used.

NOTE:
If the main power is turned off or a power failure occurs while AUTO START/STOP timer is active, the timer setting is
cancelled. As these models are equipped with an auto restart function, the air conditioner starts operating with timer
cancelled at the same time that power is restored.

MAINTENANCE

Before starting maintenance

Turn off the breaker and/or disconnect the
power supply plug.

 CAUTION:

When the unit is to be cleaned, switch it off and
disconnect the power supply plug or turn off the breaker.
Since the fan rotates at high speed during operation, it
may cause an injury.

Cleaning the indoor unit

Clean the unit using a soft dry cloth.

If the dirt is noticeable, wipe the unit with a cloth
soaked in a solution of mild detergent diluted in
lukewarm water.

Do not use gasoline, thinner, benzine, polishing
powder, or insecticide. The unit may be damaged.

The front panel may come off if it is lifted up past its
level position. If the front panel comes off, refer to
step 

3

 in CLEANING THE FRONT PANEL.

ECONO COOL

ECONO COOL

VANE

     START

     START

    STOP

    STOP

Содержание MSZ-GB35VA

Страница 1: ...nd safely be sure to read this operating instructions before use Keep this manual carefully for later reference Be sure to receive a guarantee card from your dealer and check that the purchased data and shop name etc are entered correctly This air conditioner should not be installed by the customer Safety and performance functions cannot be assured SG79Y987H01_Cover p65 07 4 16 0 05 PM 3 ...

Страница 2: ...cooling mode if the unit is operated at low outside temperature less than 10 C water condensed in the air conditioner may drop and wet or damage furniture etc CAUTION Do not use intermediate connection of the power supply cord or the extension cord and do not connect many devices to one AC outlet A fire or an electric shock may result from poor contact poor insulation exceeding the permissible cur...

Страница 3: ... or something falls down CAUTION ditioner WARNING mable gas could leak he unit it may cause an explosion as pipe water pipe lightning rod or the earth of a telephone If the an electric shock epending on the place where the air conditioner is to be installed installed it may cause an electric shock water may drop from the unit This may wet and damage the furniture CAUTION NAME OF EACH PART Indoor u...

Страница 4: ... memory If a power failure occurs or the main power is turned off during operation Auto restart function sets automatically to start operating in the same mode as the one set with the remote controller just before the shutoff of the main power Refer to page 6 for details Outdoor unit Insert the power supply plug into the power outlet and or turn the breaker on WARNING Remove dirt from the power su...

Страница 5: ... soon The recommended usable time limit is indicated month year on the bottom of the battery To prevent liquid leakage take out all batteries when the remote controller is not going to be used for a long time CAUTION If liquid from the batteries gets onto your skin or clothes wash it well with clean water If liquid from the batteries gets into your eyes wash them well with clean water and consult ...

Страница 6: ...HEAT is not stored in the memory When the main power is turned on the unit decides the operation mode by the initial room temperature at restart and starts operation again Information for multi system air conditioner Multi system air conditioner can connect two or more indoor units with one outdoor unit According to the capacity two or more units can operate simultaneously When you try to operate ...

Страница 7: ...F ON OFF ON OFF AIR FLOW VELOCITY AND DIRECTION ADJUSTMENT To change the AIR FLOW velocity press the button Each time the button is pressed the fan speed is changed in sequence Low Med High Super High AUTO Use the Super High notch to cool heat the room more efficiently If the operating sound of the air conditioner disturbs your sleep use the Low notch To change the AIR FLOW blowing direction verti...

Страница 8: ...y your fingers may be caught To change the air flow direction not to blow directly onto your body To change the air flow direction Pressing and holding the VANE button for 2 seconds or more causes the horizontal vane to reverse and move to horizontal position Horizontal position When to use this function Use this function if you don t want the air from the indoor unit to blow directly onto your bo...

Страница 9: ...OL mode ase the ECONO COOL operation ss the button again hen the button is pressed or the operation mode is changed during e ECONO COOL operation ECONO COOL operation is released he FAN button the TOO WARM or TOO COOL button and ON OFF timer explained below e available cooler than constant air flow So even though the set temperature is cooling operation with keeping comfort As a result energy can ...

Страница 10: ...of the QUICK CLEAN KIT Fan Refer to page 12 for cleaning the fan Heat exchanger CLEANING THE CATECHIN AIR FILTER Cleaning the catechin air filter about once every 2 weeks What is Catechin air filter The air filter is dyed with a natural material catechin that is contained in tea The catechin air filter deodorizes odor and noxious gases such as formaldehyde ammonia and acetaldehyde Moreover it rest...

Страница 11: ...r left one The air cleaning filter is not attached to the right side catechin air filter 2 Pull up the tabs on both sides of the air clean ing filter with your finger and remove the air cleaning filter blue bellows type from the catechin air filter 3 Attach a new air cleaning filter to the catechin air filter so that all 8 tabs on the catechin air filter are securely installed 4 Install the catech...

Страница 12: ...sive force to the fan Otherwise it may be cracked Groove 1 2 Stopper Insert this end first Left Lock 5 Put the vertical vanes back to their original positions one by one 2 Push each vertical vane until it clicks into place 1 Hold the tab of each vertical vane and insert the vertical vanes into their respective grooves Be sure to hold the tabs to install the vertical vanes otherwise the vanes can b...

Страница 13: ...th unction the air conditioner erating again Refer to TO RESTART FUNCTION on Question The air flow direction changes during operation The direction of the horizontal vane cannot be adjusted with the remote controller Water leaks from the outdoor unit White smoke is discharged from the outdoor unit Air does not blow out soon in the heating operation The operation is stopped for about 10 minutes in ...

Страница 14: ...e unit be inspected and maintained charged by specialist in addition to normal maintenance Consult your dealer Operating sound considerations Do not put an object around the air outlet of the outdoor unit This may lower the capacity or increase the volume of the operating sound If an abnormal sound is heard during operation consult your dealer Relocation When the air conditioner is to be removed o...

Страница 15: ......

Страница 16: ...HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODAKU TOKYO 100 8310 JAPAN SG79Y987H01 SG79Y987H01_Cover p65 07 4 16 0 05 PM 2 ...

Отзывы: