35
10-7. TEST POINT DIAGRAM AND VOLTAGE
1. Indoor electronic control P.C. board, indoor terminal P.C. board, receiver P.C. board,
switch/buzzer
P.C. board
and
display
P.C. board
MSZ-FT25VG MSZ-FT35VG MSZ-FT50VG
MSZ-FT25VGK MSZ-FT35VGK MSZ-FT50VGK
Indoor electronic control
P.C. board
Indoor terminal
P.C. board
Receiver P.C. board
Switch/buzzer
P.C. board
Display
P.C. board
Room temperature thermistor (RT11)
Indoor coil thermistor (RT12, RT13)
Temperature (°C)
Resistance (kΩ)
Connector to
Indoor fan motor
(CN211)
Resistor (R111)
Room temperature
thermistor RT11
(CN111)
Connector to
Indoor coil thermistor
RT12, RT13
(CN112)
Connector to
vane motor
(CN151)
12 V DC
5 V DC
GND
To disable
"Auto restart function",
cut the Jumper wire
to JR77. (Refer to 8-3.)
Fuse (F11)
T3.15AL250V
Varistor
(NR11)
Emergency operation
switch (E.O. SW) (SW1)
Connector to
Wi-Fi interface
(CN110)
Cut the jumper wire JR24 when
the room temperature does not
reach the set temperature
during heating operation.
(Refer to 8-5.)
OBH864