2-4-2. DRAIN PIPING

•  If the extension drain hose has to pass through a room, be sure to wrap it with insula-

WLRQ¿HOGVXSSOLHG

•  The drain hose should point downward for easy drain. (Fig. 1)

‡ ,IWKHGUDLQKRVHSURYLGHGZLWKWKHLQGRRUXQLWLVWRRVKRUWFRQQHFWLWZLWKD¿HOGVXSSOLHG

drain hose (I). (Fig. 2)

•  When connecting the drain hose to a hard vinyl chloride pipe, be sure to insert it 

securely into the pipe. (Fig. 3)

Do not make drain piping as shown below.

Do not raise

Accumulated 

drain water

Air

Waving

Water 

leakage

Water 

leakage

Water 

leakage

Tip of drain 

hose dipped 

in water

Ditch

At least

1-31/32 in. 

(50 mm) 

gap

Downward 

slope

Drain 

hose

Soft hose 

I.D. 19/32 in. 

(15 mm)

Drain hose
Hard vinyl chloride pipe 

I.D. 1-3/16 in.

(30 mm)

Insert  

securely

Different 

diameter 

joint

27-9/16 in.

(70 cm)

 or more

Fig. 1

Fig. 2

Fig. 3

Liquid pipe

Gas pipe

Felt tape (4) 

Indoor/outdoor unit 

connecting wire (A)

Piping tape (G)

2-4. PIPE FORMING AND DRAIN PIPING

2-4-1. PIPE FORMING

•  Place the drain hose below the refrigerant piping.

•  Make sure that the drain hose is not crowded or bent.

•  Do not pull the hose when applying the tape.

•  When the drain hose passes the room, be sure to wrap it with insulation material 

¿HOGVXSSOLHG

Note:

Make sure not to damage the cover of refrigerant pipe when attaching it back on with 

screws.

Left or left-rear piping

Note:

Be sure to reattach the drain hose and the drain cap if the piping is being installed on 

left or bottom left of unit, otherwise, water could drip down from the drain hose.

3ODFHWKHUHIULJHUDQWSLSLQJDQGWKHGUDLQKRVHWRJHWKHUWKHQ¿UPO\DSSO\IHOWWDSH

from the end. 

  Felt tape (4) overlap width should be 1/3 the tape width. Use a bandage stopper at the 

end of felt tape (4).

2) Pull out the drain cap at the back right of the indoor unit. (Fig. 1)

•  Hold the convex section at the end and pull the drain cap.

3) Pull out the drain hose at the back left of the indoor unit. (Fig. 2)

•  Hold the claw marked by the arrows and pull out the drain hose forward.

4) Put the drain cap into the section to which the drain hose is to be attached at the rear 

of the indoor unit. (Fig. 3)

•  Insert a screwdriver into the hole on the cap and insert the cap fully into the 

drain pan.

5) Insert the drain hose fully into the drain pan at the back right of the indoor unit. (Fig. 4)

•  Check if the hose is hooked securely to the projection of its inserting part at the 

drain pan.

6) Insert the drain hose into wall hole sleeve (C), and attach the upper part of indoor unit 

onto the installation plate (1). Then, shift the indoor unit completely to the left to make 

placing the piping in the back of the unit easier.

7) Cut out a piece of cardboard from the shipping box, roll it up, hook it onto the back rib, 

and use it as a spacer to lift the indoor unit. (Fig. 5)

8) Connect the refrigerant piping with the extension pipe (B).

9) Attach the lower part of the indoor unit into the installation plate (1).

Remove panel for piping 

on left side of unit.

Drain cap

Drain hose

Drain cap

Drain hose

Fig. 1

Fig. 2

Fig. 3

Fig. 4

Fig. 5

Piping tape (G)

Felt tape (4)

Rear or bottom piping

3ODFHWKHUHIULJHUDQWSLSLQJDQGWKHGUDLQKRVHWRJHWKHUWKHQ¿UPO\DSSO\SLSLQJWDSH

(G) from the end.

2) Insert the piping and the drain hose into the wall hole sleeve (C), and attach the upper 

part of the indoor unit on the installation plate (1).

3) Check if the indoor unit is attached securely on the installation plate (1) by moving the 

unit to left and right.

4) Attach the lower part of the indoor unit into the installation plate (1).

Right piping

Note:

Before performing the following, make sure that wiring is completed, and the conduit 

cover is installed. (Refer to 2-3.)

1) Place the refrigerant piping and the drain hose together, shift them to left side of the 

XQLWDQGWKHQ¿UPO\DSSO\SLSLQJWDSH*IURPWKHHQG

2) Insert the piping and the drain hose into the wall hole sleeve (C), and attach the upper 

part of the indoor unit on the installation plate (1).

3) Check if the indoor unit is attached securely on the installation plate (1) by moving the 

unit to left and right.

4) Attach the lower part of the indoor unit into the installation plate (1).

To the left

Remove corner 

box for piping 

on right side 

of unit

Remove corner box for piping 

on bottom side of unit

Содержание MSZ-FS06NA

Страница 1: ...power supply plug or the outlet it could FDXVH HOHFWULF VKRFN RU UH I ORRVH SDUWV DUH IRXQG RQ WKH SRZHU VXSSO SOXJ UHSODFH LW Securely attach the electrical cover to the indoor unit and the service panel to the outdoor unit If the electrical cover of the indoor unit and or the service panel of the outdoor unit are QRW DWWDFKHG VHFXUHO GXVW ZDWHU HWF FRXOG FROOHFW LQ WKH XQLW DQG FRXOG FDXVH D UH ...

Страница 2: ...fore use Where it can be easily drained At a distance 3 ft 1 m or more away from a TV and radio Operation of the air conditioner may interfere with UDGLR RU 79 UHFHSWLRQ Q DPSOL HU PD EH UHTXLUHG IRU the affected device Q D SODFH DV IDU DZD DV SRVVLEOH IURP ÀXRUHVFHQW DQG incandescent lights In order to make the infrared remote control operate the air conditioner normally The heat from the lights ...

Страница 3: ...t by drain water or damaged by frozen drain water 4 7 8 in 122 5 mm or more 3 3 8 in 85 mm or more 5 11 16 in 143 mm or more for left left rear piping using spacer 2 3 16 in 56 mm or more 5 1 4 in 132 5 mm or more 33 1 16 13 3 4 14 5 8 19 11 16 Air inlet Air inlet Air inlet Air inlet Air inlet 6 7 8 15 3 8 13 Air outlet 2 3 8 13 16 slot 1 9 16 40 840 175 500 Air inlet 390 330 349 371 Air outlet 2 ...

Страница 4: ...rminal of electrical parts box 7 Process the end of indoor outdoor unit connecting wire A Fig 3 Attach it to the terminal block Be careful not to make mis wiring Attach the wire to the terminal block securely so that its core cannot be seen and no external force affects the connecting section of the terminal block 8 Firmly tighten the terminal screws After tightening verify that the wires are tigh...

Страница 5: ...ection to which the drain hose is to be attached at the rear of the indoor unit Fig 3 Insert a screwdriver into the hole on the cap and insert the cap fully into the drain pan 5 Insert the drain hose fully into the drain pan at the back right of the indoor unit Fig 4 Check if the hose is hooked securely to the projection of its inserting part at the drain pan 6 Insert the drain hose into wall hole...

Страница 6: ...HFWLYH FXW RII WKH VHFWLRQ DQG UHSHDW SURFHGXUH Terminal block Power supply cord K Indoor outdoor unit connecting wire A Make ground wire a little longer than others More than 4 in 100 mm For future servicing leave some slack in the connecting wires Be sure to attach each screw to its corre spondent terminal when securing the cord and or the wire to the terminal block Pipe diameter inch mm B inch ...

Страница 7: ...Otherwise composition of the refrigerant in the system may be changed and affect performance of the air conditioner 10 Remove gauge manifolds and replace service port caps and tighten 11 Leak test 4 2 TEST RUN 1 Insert power supply plug into the power outlet and or turn on the breaker 2 Press the E O SW once for COOL and twice for HEAT operation Test run will be performed for 30 minutes If the lef...

Страница 8: ... 5 2 REMOVING THE INDOOR UNIT Remove the bottom of the indoor unit from the installation plate When releasing the corner part release both left and right bottom corner part of indoor XQLW DQG SXOO LW GRZQZDUG DQG IRUZDUG DV VKRZQ LQ WKH JXUH RQ WKH ULJKW Installation procedure 1 Install the panel assembly following the removal procedure in reverse 2 Be sure to press the positions as indicated by t...

Отзывы: