background image

SPLIT-TYPE AIR CONDITIONERS

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS

For customers

To use this unit correctly and safely, be sure to read this instruction manual before
use.

Bedienungsanleitung

Für Kunden

Um diese Einheit richtig und sicher zu verwenden, unbedingt diese Bedienungs-
anleitung vor der Inbetriebnahme durchlesen.

NOTICE D’UTILISATION

A l’attention des clients

Pour avoir la certitude d’utiliser cet appareil correctement et en toute sécurité, veuillez
lire attentivement cette notice d’instructions avant de mettre l’appareil en fonction.

GEBRUIKSAANWIJZING

Voor de klant

Lees deze gebruiksaanwijzing alvorens gebruik goed door voor een veilig en juist
gebruik van deze airconditioner.

MANUAL DE INSTRUCCIONES

Para los clientes

Para emplear correctamente este aparato, lea este manual de instrucciones an-
tes de la utilización.

LIBRETTO D’ISTRUZIONI

Per gli utenti

Per utilizzare correttamente quest’unità, leggere queste manuale attentamente e
per intero.

√¢∏°π∂™ §∂π∆√Àƒ°π∞™

°È· ÙÔÓ ÂÏ¿ÙË

°È· Ó· ¯ÚËÛÈÌÔÔÈ‹ÛÂÙ ·˘Ù‹ ÙËÓ ÌÔÓ¿‰· ÛˆÛÙ¿ Î·È Ì ·ÛÊ¿ÏÂÈ·, ‚‚·Èˆı›ÙÂ
fiÙÈ ¤¯ÂÙ ‰È·‚¿ÛÂÈ ·˘Ùfi ÙÔ ÂÁ¯ÂÈÚ›‰ÈÔ Ô‰ËÁÈÒÓ ÚÈÓ ·fi ÙËÓ ¯Ú‹ÛË.

MANUAL DE INSTRUÇÕES

Para os clientes

Para utilizar esta unidade correctamente, certifique-se de ler este manual de
instruções antes do uso.

BRUGSANVISNING

Til kunden

Læs denne brugsanvisning før brugen så korrekt og forsvarlig anvendelse af klima-
anlægget sikres.

INSTRUKTIONSHANDBOK

För kunder

För att använda denna enhet på ett korrekt och säkert sätt, se till att du läser
denna instruktionshandbok innan du tar den i bruk.

ÇALIfiTIRMA ‹LE ‹LG‹L‹ TAL‹MATLAR

Sat›n al›c›lar için

Klimay› do¤ru ve rahat kullanman›z aç›s›ndan kullanmaya geçmeden evvel k›lavuz
kitap盤›n› okuyunuz.

ADVANCED AND EVER ADVANCING

English

Deutsch

Français

Nederlands

Español

Italiano

∂ÏÏËÓÈο

Português

Dansk

Svenska

Türkçe

MSZ-A09RV
MSZ-A12RV

Содержание MSZ-A09RV

Страница 1: ...strucciones an tes de la utilización LIBRETTO D ISTRUZIONI Per gli utenti Per utilizzare correttamente quest unità leggere queste manuale attentamente e per intero π π Àƒ π È ÙÔÓ ÂÏ ÙË È Ó ÚËÛÈÌÔ ÔÈ ÛÂÙ ٠ÙËÓ ÌÔÓ ÛˆÛÙ Î È Ì ÛÊ ÏÂÈ Â Èˆı Ù fiÙÈ ÂÙÂ È ÛÂÈ Ùfi ÙÔ ÂÁ ÂÈÚ ÈÔ Ô ËÁÈÒÓ ÚÈÓ fi ÙËÓ Ú ÛË MANUAL DE INSTRUÇÕES Para os clientes Para utilizar esta unidade correctamente certifique se de ler este...

Страница 2: ...children or infirm persons without supervisions Do not turn the breaker off on or dis connect connect the power plug during operation This may cause a fire due to spark etc Be sure to turn off the breaker or disconnect the power plug absolutely after switching the indoor unit off with the remote controller Do not expose your skin directly to cool air for a long time This could damage your health W...

Страница 3: ...tep or put any thing on the indoor out door unit This may cause an injury through dropping or falling down Do not leave the unit on an installation stand which is damaged The unit may drop or fall down and this may cause an injury Do not operate the unit for a long time in high humidity e g leaving a door or window open In the cooling mode if the unit is operated in a room with high hu midity 80 R...

Страница 4: ...ERATION 10 TIMER OPERATION ON OFF TIMER 11 WHEN THE AIR CONDITIONER IS NOT GOING TO BE USED FOR A LONG TIME 11 MAINTENANCE 12 CLEANING THE AIR FILTER AND THE DEODORIZING FILTER 12 REPLACEMENT OF THE DEODORIZING FILTER AIR CLEANING FILTER 13 BEFORE CONTACTING THE SERVICE REPRESENTATIVE CHECK THE FOLLOWING AGAIN 13 WHEN YOU THINK THAT TROUBLE HAS OCCURRED 14 INSTALLATION RELOCATION AND INSPECTION 15...

Страница 5: ...emote control receiving section Horizontal vane Remote controller Display section Emergency operation switch Power monitor lamp Receiving section Air inlet back and side Piping Drainage hose Air outlet Drain outlet Signal transmitting section Operation display section ON OFF operate stop button Operation select button Fan speed control button ECONO COOL button On timer button CLOCK set button HR b...

Страница 6: ...e batteries of the remote controller run out or the remote controller malfunctions the emergency op eration can be done using the EMERGENCY OPERA TION switch 1 Press the EMERGENCY OPERA TION switch Each time the EMERGENCY OPERATION switch is pressed the unit will operate in or der of EMERGENCY COOL MODE EMER GENCY HEAT MODE and STOP MODE However when the EMERGENCY OPERA TION switch is once pressed...

Страница 7: ...ows the room temperature The set temperature lit lamp can be adjusted to 2 C either above or below the room temperature blinking lamp GREEN SIGN This shows the current room temperature and the set temperature target temperature The room temperature indicated on the GREEN SIGN may not be exactly the same as the actual room temperature In order to prevent large changes in the room temperature the un...

Страница 8: ...e 7 NOTE When the ambient temperature is too high the room tem perature may not reach the set temperature since the unit operates to cool under high load CONVENIENT INFORMATION COOL For effective cooling 1 Close the windows and pull down blinds Sunshine is re duced and cooling efficiency increases 2 Paste a heat shield film gen erally available on the window Heat entering the room is re duced 3 Bl...

Страница 9: ...the desired position press the SWING button again The vanes stop moving Horizontal AIR FLOW blowing range Auto air flow direction control operation When the AUTO mode is selected with the VANE button the position of the horizontal vane is automatically set to correspond to the operation mode to operate effectively 1 HEAT When the output air temperature is too low The output air temperature rising ...

Страница 10: ...NO COOL operation is released The FAN button the TOO WARM or TOO COOL button and ON OFF timer page 11 are available What is ECONO COOL Swing air flow change of air flow makes you feel cooler than constant air flow So even though the set tempera ture is automatically set 2 C higher it is possible to oper ate cooling operation with keeping comfort As a result energy can be saved ON OFF HR FAN VANE C...

Страница 11: ... If the current time has not been set the timer operation can not be done WHEN THE AIR CONDITIONER IS NOT GOING TO BE USED FOR A LONG TIME When it is not going to be used for a long time 1 Perform the FAN operation for 3 or 4 hours to dry the inside of the air conditioner To perform FAN operation set to the highest temperature in the MANUAL COOL OPERATION mode Refer to page 8 2 Turn off the breake...

Страница 12: ...e dirt is conspicuous use a solution of detergent in lukewarm water If hot water 50 C or more is used the filter may be deformed Do not use a scrubbing brush or sponge This may damage the surface of the filter Do not use a chlorine detergent 3 After washing with water lukewarm water dry the deodorizing filter well in the shade Do not expose the deodorizing filter to direct sunlight or heat from a ...

Страница 13: ...N Optional parts Optional parts are available from your local dealer Name of part Type name DEODORIZING FILTER MAC 1800DF AIR CLEANING FILTER MAC 1300FT The air conditioner cannot be operated d d d d d Check the following 1 Is the breaker turned on 2 Isn t the fuse blown Cannot be cooled or heated sufficiently d d d d d Check the following 1 Is the temperature set ting correct 2 Isn t the air filt...

Страница 14: ...is done the horizontal vane position is automatically set to horizontal This is the sound of the switch turning ON OFF the fan or compressor Question Water leak from the outdoor unit The sound as burbling is heard Air does not blow out quickly in the heating operation The operation is stopped for about 10 minutes in the heating operation Hissing sound is sometimes heard Answer not a malfunction Du...

Страница 15: ...r conditioner Be sure to observe the breaker capacity WARNING The customer should not install this unit If installation is done incorrectly it may cause a fire an electric shock or injury from the unit fall ing water leaking etc Do not connect using a branched outlet or an ex tension cord and do not attach many loads to one electric outlet A fire or an electric shock may result from poor contact p...

Страница 16: ...G79A121H02 This product is designed and intended for use in the residential commercial and light industrial environment The product at hand is based on the following EU regulations Low Voltage Directive 73 23 EEC Electromagnetic Compatibility Directive 89 336 EEC Machinery Directive 89 392 EEC ...