MSXY-FN20VE MSXY-FN24VE
1. Indoor power P.C. board
GND
12V
5V
Fuse (F11)
T3.15AL250V
Varistor (NR11)
Connector to indoor electronic
control P.C. board (CN20A)
5 V DC
12 V DC
GND
Connector to Indoor fan
motor (CN211)
Resistor (R111)
Connector to
Terminal block
(CN201)
(+)3-6 V DC
15 V DC
(-) GND
(High voltage DC)
325 V DC
(+)0 or 15 V DC
Timer short
mode point
(Refer to 8-1.)
Room temperature thermistor RT11 (CN111)
Interlock
switch (FAN)
(CN1R1)
Connector to
Indoor coil ther-
mistor RT12,
RT13 (CN112)
Vane motor
(CN151)
Connector to indoor power
P.C. board (CN10A)
5V DC
To disable
"Auto restart
function",cut the
Jumper wire to
JR77. (Refer to
8-3.)
Emergency operation
switch (E.O. SW) (SW1)
GND
2.
Indoor electronic control P.C. board
Room temperature thermistor (RT11)
Indoor coil thermistor (RT12, RT13)
Temperature (°C)
Resistance (kΩ)
12 V DC