En-9
● OPERATING INSTRUCTIONS ●
Installation place
Avoid installing the air conditioner in the following places.
• Where there is much machine oil.
• Salty places such as the seaside.
• Where sulfi de gas is generated such as hot spring, sewage, waste water.
• Where oil is splashed or where the area is fi lled with oily smoke (such as cook-
ing areas and factories, in which the properties of plastic could be changed
and damaged).
• Where there is high-frequency or wireless equipment.
• Where the air from the outdoor unit air outlet is blocked.
• Where the operation sound or air from the outdoor unit bothers the house next
door.
• The mounting height of indoor unit 1.8 m to 2.3 m is recommended. If it is
impossible, please consult your dealer.
• Do not operate the air conditioner during interior construction and fi nishing
work, or while waxing the fl oor. Before operating the air conditioner, ventilate
the room well after such work is performed. Otherwise, it may cause volatile
elements to adhere inside the air conditioner, resulting in water leakage or
scattering of dew.
Electrical work
• Provide an exclusive circuit for the power supply of the air conditioner.
• Be sure to observe the breaker capacity.
If you have any questions, consult your dealer.
I
NSTALLATION PLACE AND
ELECTRICAL WORK
S
PECIFICATIONS
1
Operate by COOL mode with the highest temperature
set or FAN mode for 3 to 4 hours.
Page 4
• This dries the inside of the unit.
• Moisture in the air conditioner contributes to favorable conditions for
growth of fungi, such as mold.
2
Press
to stop the operation.
3
Turn off the breaker and/or disconnect the power sup-
ply plug.
4
Remove all batteries from the remote controller.
When using the air conditioner again:
1
Clean the air fi lter.
Page 7
2
Check that the air inlet and outlet of the indoor and
outdoor units are not blocked.
3
Check that the earth is connected correctly.
4
Refer to the “PREPARATION BEFORE OPERATION”,
and follow the instructions.
Page 3
W
HEN THE AIR CONDITIONER IS NOT
GOING TO BE USED FOR A LONG TIME
Rating condition
Model
Set name
MS-GH13VA
Indoor
MS-GH13VA
Outdoor
MU-GH13VA
Power supply
~/N, 220-230-240V, 50Hz
Capacity
kW
3.45-3.45-3.45
Input (set)
kW
1.09-1.12-1.14
Rated current (set)
A
5.0-5.0-5.0
Weight
Indoor
kg
9
Outdoor
kg
34
Dimensions
H × W × D
Indoor
mm
295 × 798 × 232
Outdoor
mm
525 × 718 × 255
Power supply
~/N, 230V, 50Hz
Net total cooling capacity
kW
2.915
Btu/h
9946
Energy Effi ciency Ratio (EER)
Btu/h/W
7.76
Annual Energy Consumption
kWh
1281
Indoor
Outdoor
Upper limit
35°C DB
24°C WB
46°C DB
—
Lower limit
21°C DB
15°C WB
21°C DB
—
Guaranteed operating range
T3 condition (Tested data)
DB: Dry Bulb
WB: Wet Bulb
Note:
Rating condition
Indoor: 27°C DB, 19°C WB
Outdoor: 35°C DB, 24°C WB
T3 condition
Indoor: 29°C DB, 19°C WB
Outdoor: 46°C DB, 24°C WB
To prevent the ef-
fects of a fl uorescent
lamp, keep as far
apart as possible.
wall, etc.
Inverter-type
fl uorescent lamp
Keep a space
to prevent the
picture distortion
or the noise.
1 m
or more
Radio
100 mm or
more
200 mm or
more
TV
Cordless
phone or
Portable
phone
3 m or
more
1 m
or more
The installation location of the outdoor
unit should be at least 3 m away from the
antennas for TV sets, radios, etc. In areas
where the reception is weak, provide greater
space between the outdoor unit and the
antenna of the affected device if operation
of the air conditioner interferes with radio or
TV reception.
For the optimum effi ciency
and to extend the life time
of using, the outdoor unit
should be installed in a
well-ventilated dry place.
JG79Y165H02_en.indd 9
2016/12/20 19:01:01