17
2. Vertical vane (MS-GH18/24/30VA)
(1) Vane motor drive
These models are equipped with a stepping motor for the vertical vane. The rotating direction, speed, and angle of
the motor are controlled by pulse signals (approximately 12 V) transmitted from microprocessor.
(2) The vertical vane angle and mode change as follows by pressing WIDE VANE CONTROL button.
(3) Positioning
To confirm the standard position, the vane moves until it touches the vane stopper. Then the vane is set to the select-
ed angle.
(SWING)
1
2
3
4
5
6
Confirming of standard position is performed in the following cases:
(a) OPERATE/STOP (ON/OFF)
(MS-GH13/18/24/30VA-
KU1
)/
STOP/OPERATE (OFF/ON)
(MS-GH13/18VA-
KU2
,
KU2
U
)
button is pressed (POWER ON).
(b) SWING is started.
(4) SWING (
) MODE
By selecting SWING mode with WIDE VANE button, the vertical vane swings horizontally. The remote controller
displays “
”. Swing mode is cancelled when WIDE VANE button is pressed once again.
(5) WIDE MODE (
)
By selecting WIDE mode with WIDE VANE button, indoor fan speed becomes faster than setting fan speed on the
remote controller ( ). The remote controller displays “
”.
Indoor fan speed becomes faster than setting fan speed on the remote controller even when
or
is selected.
1. How to set the time
(1) Check that the current time is set correctly.
NOTE:
Timer operation will not work without setting the current time. Initially “0:00” blinks at the current time display
of TIME MONITOR, so set the current time correctly with CLOCK button.
How to set the current time
(a) Press the CLOCK button.
(b) Press the TIME SET buttons (
and
) to set the current time.
• Each time FORWARD button (
) is pressed, the set time increases by 1 minute, and each time BACKWARD
button (
) is pressed, the set time decreases by 1 minute.
• Pressing those buttons longer, the set time increases/decreases by 10 minutes.
(c) Press the CLOCK button.
(2) Press OPERATE/STOP (ON/OFF)
(MS-GH13/18/24/30VA-
KU1
)/
STOP/OPERATE (OFF/ON)
(MS-GH13/18VA-
KU2
,
KU2
U
)
button to start the air conditioner.
(3) Set the time of timer.
ON timer setting
(a) Press ON TIMER button(
) during operation.
(b) Set the time of the timer using TIME SET buttons (
and
).
OFF timer setting
(a) Press OFF TIMER button (
) during operation.
(b) Set the time of the timer using TIME SET buttons (
and
).
Each time FORWARD button (
) is pressed, the set time increases by 10 minutes: each time BACKWARD
but-
ton (
) is pressed, the set time decreases by 10 minutes.
8-6. TIMER OPERATION
COOL / DRY
Fan speed : Faster
Solid arrow : When the LONG mode is used.
Dotted arrow : When the LONG mode is not used.
(10) LONG MODE (
)
(MS-GH18/24/30VA)
By pressing LONG button indoor fan speed becomes faster than setting fan speed on the remote controller, and the
horizontal vane moves to the position for LONG mode. The remote controller displays “
”. To cancel this opera-
tion, press one of the following buttons: LONG, VANE CONTROL, or ECONO COOL (during cool mode). In the fol-
lowing example, the vertical vane is set to
(front.).
OBH664B