8-1. COOL ( ) OPERATION
(1) Press OFF/ON (stop/operate) button.
OPERATION INDICATOR lamp of the indoor unit turns ON with a beep tone.
(2) Select COOL mode with Operation select button.
(3) Press Temperature buttons (TOO WARM or TOO COOL button) to select the desired temperature. The setting range is
16 - 31°C.
1. Coil frost prevention
When the temperature of indoor heat exchanger becomes too low, the coil frost prevention mode works.
The indoor fan operates at the set speed and the compressor stops. This mode continues until the temperature of indoor
heat exchanger rises.
8-2. DRY ( ) OPERATION
(1) Press OFF/ON (stop/operate) button.
OPERATION INDICATOR lamp of the indoor unit turns ON with a beep tone.
(2) Select DRY mode with Operation select button.
(3) The set temperature is determined from the initial room temperature.
1. Coil frost prevention
Coil frost prevention works the same way as that in the COOL mode. (8-1.1.)
8
-3. FAN ( )OPERATION
(1) Press OFF/ON (stop/operate) button. OPERATION INDICATOR lamp of the indoor unit turns ON with a beep tone.
(2) Select FAN mode with Operation select button.
(3) Select the desired fan speed. When AUTO, it becomes Low. Only indoor fan operates. Outdoor unit does not operate.
Mode
COOL mode of
"I FEEL CONTROL"
DRY mode of
"I FEEL CONTROL"
Initial room temperature
25 or more
more than 13 ,
less than 25
8-4. “I FEEL CONTROL” ( ) OPERATION
(1) Press OFF/ON (stop/operate) button on the remote controller. OPERATION INDICATOR lamp of the indoor unit turns
ON with a beep tone.
(2) Select “I FEEL CONTROL” mode with the Operation select button.
(3) The operation mode is determined by the room temperature at
start-up of the operation.
• Once the mode is fixed, the mode does not change by the room temperature afterwards.
• Under ON-TIMER (
) operation, mode is determined as follows:
When the system is stopped by the remote controller, and restarted within 2 hours in “I FEEL CONTROL” ( ) mode,
the system operates in previous mode automatically regardless of the room temperature.
Previous operation
COOL mode of
“I FEEL CONTROL”
or COOL mode
Restart
COOL mode of
“I FEEL CONTROL”
Operation timer chart
Example
INDOOR UNIT DISPLAY SECTION
Operation Indicator lamp
The operation indicator at the right side of the indoor unit indicates the operation state.
•The following indication applies regardless of shape of the indication.
Indication
Operation state
Room temperature
MS-CP13/18/24VA
MS-CP30VA
The unit is operating to
reach the set temperature
About 2°C or more away
from set temperature
The room temperature is
approaching the set tem-
perature
About 1 to 2°C from set
temperature
Lit
Not lit
OBH782A