2
MICROPROCESSOR CONTROL
Once the operation mode are set, the same operation mode
can be repeated by simply turning the
OPERATE/STOP(ON/OFF) button ON.
Indoor unit receives the signal with a beep tone.
When the system turns off, compressor will not restart for 3
minutes as 3-minute time delay function operates to protect
compressor from overload.
Signal transmitting section
Operation display section
TEMPERATURE buttons
VANE CONTROL button
TIME SET button
RESET button
FAN SPEED CONTROL button
ECONO COOL button
POWERFUL COOL button
OPERATION SELECT button
TIMER MODE SELECT button
OPERATE/STOP (ON/OFF) button
WIRELESS REMOTE CONTROLLER
MS-A08ND -
MS-A10ND -
MS-A12ND -
MS-A15ND -
MU-A08ND -
MU-A10ND -
MU-A12ND -
MU-A15ND -
C1
C1
C1
C1
C1
C1
C1
C1
Lighted
Not lighted
Approx. 2
:
or more
Difference
between target
temperature
and room
temperature
Approx. 2
:
or less
This shows that the
air conditioner is
operating to reach
the target temperature.
Please wait unit the
target temperature is
obtained.
This shows that the
room temperature is
approaching the
target temperature.
Operation state
Indication
Operation Indicator
Operation Indicator lamp
The operation indicator at the right side of the indoor
unit indicates the operation state.
INDOOR UNIT DISPLAY SECTION
• The following indication applies regardless of shape
of the indicator.
●
Once the mode is fixed, the mode does not change by
room temperature afterwards.
●
Under ON-TIMER (
) operation, the mode is deter-
mined according to the room temperature at set time the
operation starts.
●
When the system is stopped by the remote controller and
restarted within 2 hours in “I FEEL CONTROL” (
)
mode, the system operates in previous mode automatically
regardless of the room temperature.
1. “I FEEL CONTROL”
(
)
OPERATION
(1) Press OPERATE/STOP(ON/OFF) button on the remote
controller. OPERATION INDICATOR lamp of the indoor
unit turns on with a beep tone.
(2) Select “I FEEL CONTROL”(
) mode with the
OPERATION SELECT button.
(3) The operation mode is determined by the initial room
temperature at start-up of the operation.
Initial room temperature
Mode
25°C or more
COOL mode of
“I FEEL CONTROL”
DRY mode of
“I FEEL CONTROL”
more than 13°C,
less than 25°C
Operation time chart
Example
Previous operation
COOL mode of
“I FEEL CONTROL”
or COOL mode
Operation time chart
Example
Previous operation
COOL mode of
“I FEEL CONTROL”
or COOL mode
When the system is restarted after 2 hours and
more, the operation mode is determined by the
room temperature at start-up of the operation.
Restart
COOL mode of
“I FEEL CONTROL”
Restart
COOL or DRY mode of
“I FEEL CONTROL” that
determined by room
temperature at start-up
of the operation.