5. Electrical work

•  Perform wiring as shown in the diagram to the lower left. (Procure the cable locally) 

(Fig. 5-)

Make sure to use cables of the correct polarity only.

A

 Connecting cable

B

 Indoor terminal block

C

 Outdoor terminal block

D

 Always install an earth wire longer than other cables.

E

 Power supply cord

 Caution:

•  Use care not to make miswiring.

•  Firmly tighten the terminal screws to prevent then from loosening.

•  After tightening, pull the wires lightly to confirm that they do not move.

•  Connect cable from the indoor unit correctly on the terminal-block.

•  Use the same terminal block and polarity as is used with the indoor unit.

•  For aftercare maintenance, give extra length to connecting cable.

•  Both end of connecting cable (extension wire) are peeled off. When too 

long, or connected by cutting off the middle, peel off power supply cable to 

the size given in the figure.

•  Be careful not to contact connecting cable with piping.

 Caution:

•  Use care not to make miswiring. (Fig. 5-3)

•  Firmly tighten the terminal screws to prevent them from loosening.

•  After tightening, pull the wires lightly to confirm that they do not move.

 Warning:

•  Be sure to attach the service panel of the outdoor unit securely. If it is not 

attached correctly, it could result in a fire or an electric shock due to dust, 

water, etc.

•  Tighten terminal screws securely.

•  Wiring should be done so that the power lines are not subject to tension. 

Otherwise, heat may be generated or fire may occur.

L N

Fig. 5-2

Indoor terminal block

Earth wire (green/yellow)

Indoor/outdoor unit connecting 

wire 3-core 1.5 mm² or more

Outdoor terminal block

Power supply cord SUZ-SA71: .5 mm² or more

A

 Loosen terminal screw

B

 Terminal block

C

 Lead wire

Service panel

 SUZ-SA71VA

Remove fixing 

screw to open the 

service panel.

Be sure to fix the 

indoor/outdoor unit 

connecting wire us-

ing this cord clamp.

Fig. 5-3

01_RG79Y622H02_EN.indd   6

2014/03/27   11:02:18

Содержание Mr.SLIM SUZ-SA71VA

Страница 1: ...nt MANUAL DE INSTALACIÓN Para un uso correcto y seguro lea detalladamente este manual y el manual de instalación de la unidad interior antes de instalar la unidad de aire acondicionado MANUALE DI INSTALLAZIONE Per un uso sicuro e corretto leggere attentamente il presente manuale ed il manuale d installazione dell unità interna prima di installare il condizionatore d aria EΓΧEIPIΔIO OΔHΓIΩN EΓKATAΣ...

Страница 2: ... the air conditioner use only the specified refrigerant R410A to charge the refrigerant lines Do not mix it with any other refrigerant and do not allow air to remain in the lines If air is mixed with the refrigerant then it can be the cause of abnormal high pressure in the refrigerant line and may result in an explosion and other hazards The use of any refrigerant other than that specified for the...

Страница 3: ...indoor and outdoor units the length of refrigerant pipe and the number of bends in the pipe are within the limits shown below Models A Pipe length one way B Height difference C Number of bends one way SUZ SA71 Max 30 m Max 30 m Max of 10 Height difference limitations are binding regardless of which unit indoor or out door is positioned higher Refrigerant adjustment If pipe length exceeds 7 m addit...

Страница 4: ... flaring work again a Smooth all around f Scratch on flared plane b Inside is shining without any scratches g Cracked c Even length all around h Uneven d Too much i Bad examples e Tilted Apply a thin coat of refrigeration oil on the seat surface of pipe Fig 4 8 For connection first align the center then tighten the first 3 to 4 turns of flare nut Use tightening torque table below as a guideline fo...

Страница 5: ...n close the gage manifold valve and stop the vacuum pump Leave it as is for one or two minutes Make sure the pointer of the gage mani fold valve remains in the same position Confirm that the pressure gage show 0 101 MPa 760 mmHg Remove the gage manifold valve quickly from the service port of the stop valve After refrigerant pipes are connected and evacuated fully open all stop valves on gas and li...

Страница 6: ...he size given in the figure Be careful not to contact connecting cable with piping Caution Use care not to make miswiring Fig 5 3 Firmly tighten the terminal screws to prevent them from loosening After tightening pull the wires lightly to confirm that they do not move Warning Be sure to attach the service panel of the outdoor unit securely If it is not attached correctly it could result in a fire ...

Страница 7: ...t S2 S3 2 DC 12 V DC 24 V 1 A breaker with at least 3 mm contact separation in each poles shall be provided Use earth leakage breaker NV Make sure that the current leakage breaker is one compatible with higher harmonics Always use a current leakage breaker that is compatible with higher harmonics as this unit is equipped with an inverter The use of an inadequate breaker can cause the incorrect ope...

Страница 8: ...0 5 to 0 kgf cm2 and quickly stop the air conditioner Push the ON OFF button on the remote controller to stop the air conditioner Note that when the extension piping is very long with a large refrigerant amount it may not be possible to perform a pump down operation In this case use refrigerant recovery equipment to collect all of the refrigerant in the system 7 Turn off the power supply circuit b...

Страница 9: ... и на предприятиях легкой промышленности erklærer et fullstendig ansvar for undernevnte klimaanlegg og varmepumper ved bruk i boliger samt kommersielle og lettindustrielle miljøer MITSUBISHI ELECTRIC SUZ SA71VA 1 2 3 9 Note Its serial number is on the nameplate of the product Hinweis Die Seriennummer befindet sich auf dem Kennschild des Produkts Remarque Le numéro de série de l appareil se trouve ...

Страница 10: ...talingen van het origi neel VOORZICHTIG Het lekken van koelvloeistof kan verstikking veroorzaken Zorg voor ventilatie in overeen stemming met EN378 1 Isoleer de leidingen met isolatiemateriaal Direct contact met de onbedekte leidingen kan leiden tot brandwonden of bevriezing Stop nooit batterijen in uw mond om inslikking te voorkomen Het inslikken van batterijen kan verstikking of vergiftiging ver...

Страница 11: ...ng it to the customer This product is designed and intended for use in the residential commercial and light industrial environment The product at hand is based on the following EU regulations Low Voltage Directive 2006 95 EC Electromagnetic Compatibility Directive 2004 108 EC Machinery Directive 2006 42 EC Energy related Products Directive 2009 125 EC Regulation EU No 206 2012 RoHS Directive 2011 ...

Страница 12: ...umber SUZ SA71VA Mr Slim Inverter Cassette Range Brochure SUZ SA71VA_Parts_Catalog_ OCB561 SUZ SA71VA_Installation_Manual_ RG79Y622H02 SUZ SA71VA_Declaration_of_Conformity_ CE2014B01 B03 SUZ SA71VA_ _Service_Manual_ OCH561 ...

Отзывы: