60
OCH737B
Outdoor power circuit board
Brief Check of POWER MODULE
If they are short-circuited, it means that they are broken.
Measure the resistance in the following points (connectors, etc.).
1. Check of DIODE MODULE
L1 - P1 , L2 - P1 , L3 - P1 , L1 - N1 , L2 - N1 , L3 - N1
2. Check of DIP-IPM
P2 - U , P2 - V , P2 - W , N2 - U , N2 - V , N2 - W
Note: The marks L1 , L2 , L3 , N1 , N2 , P1 , P2 , U , V and W
shown in the diagram are not actually printed on the board.
CN5
Detection of primary
current (Connect to
the outdoor noise filter
circuit board (CNCT))
CN4
Connect to the
outdoor controller
circuit board (CN4)
CN2
Connect to the outdoor controller circuit board (CN2)
1
–
5
: Power circuit board
→
Transmitting
signal to the controller board (0–5 VDC)
2
–
5
: Zero cross signal (0–5 VDC)
3
–
4
: Not used
6
–
5
: 16 VDC
7
–
5
: 16 VDC
TB-U, TB-V, TB-W
Connect to the compressor (MC)
Voltage among phases:
10–400 VAC
Diode module
U
P2
V
W
N2
L3
N1
L1
P1
L2
DIP-IPM
TAB connector
on X52CA
Connect to the
RS resistor
CN6
Thermistor
<Heat sink> (TH8)
TB-L1,
TB-L2,
TB-L3
Connect to the outdoor
noise filter circuit board
(LO1, LO2, LO3)
400 VAC
L3OUT-L3IN
Lead connect
TB-P3
Connect to the DCL
TB-P1
Connect to the DCL
5
: –
1
,
2
,
6
,
7
: +