17
PEA-RP400,500GAQ
Caution,
1.To protect fan motor from abnormal current,over current relays is installed.
Therefore, do not change factory set value of over current relays.
CONNECTOR (LOSSNAY)
CONNECTOR (WIRELESS REMOTE CONTROLLER)
CONNECTOR (CENTRALLY CONTROL)
CONNECTOR (HA TERMINAL-A)
CONNECTOR (REMOTE SWITCH)
CONNECTOR (DRAIN SENSOR)
CN32
CN41
CN51
CN90
CN31
CN2L
TB3,TB8
SYMBOL
NAME
TERMINAL BLOCK
OUTDOOR UNIT
CONNECTOR (EMERGENCY OPERATION)
SWITCH (CAPACITY CORD)
SW1
SWITCH (MODEL SELECTION)
LED (TRANSMISSION<INDOOR
·
OUTDOOR>)
LED3
LED (POWER SUPPLY<REMOTE CONTROLLER>)
LED2
LED (POWER SUPPLY)
LED1
SWE
SW2
ARRESTER
DSA,DSR
VARISTOR
ZNR5~7
SNB BOARD 1
SYMBOL
NAME
AUXILIARY RELAY
X1,2
INDOOR
CONTROLLER
BOARD
FB21,FB22
FB11,FB12
FERRITE CORE
COND/EVA TEMP
LIQUID PIPE TEMP
ROOM TEMP
52F
MAGNETIC CONTACTOR (INDOOR FAN MOTOR)
SURGE KILLER
CR
TH5-1,5-2
VARISTOR
ZNR
FUSE (T6.3AL250V)
FUSE
INDOOR UNIT
THERMISTOR
TERMINAL BLOCK
INTERNAL THERMOSTAT (INDOOR FAN MOTOR)
OVER CURRENT RELAY (INDOOR FAN MOTOR)
FAN MOTOR (INDOOR)
TH2-1,2-2
TH1-1,1-2
TB2,4-1,4-2,5
49F
51F
MF1
X4-6
AUXILIARY RELAY
NAME
REMOTE CONTROLLER
SYMBOL
TB6
TERMINAL BLOCK
Note:1.Color of earth wire is yellow and green twisting.
2.Specification subject to change without notice.
3.Indoor and outdoor connecting wires are made with polarities,make sure
matching wiring and terminal.
4.Emergency operation
If a trouble occurs with either the remote controller or the indoor
microcomputer and no other trouble exists, emergency operation for
cooling or heating
can be performed by changing the setting of connector (SWE) "ON" on the
indoor controller board.
SWE :ON / Indoor fan is running high speed.
5.Symbols used in wiring diagram above are,
:CONNECTOR
:TERMINAL
(HEAVY DOTTED LINE):FIELD WIRING
(THIN DOTTED LINE)
:OPTIONAL PARTS
6.(*1)SW2 shows PEA-RP500 setting.(2places)
In case of PEA-RP400 setting is shown as below.
12
4
3
OFF
ON
5
(*1)SW2
M
1~
PE
CIRCUIT BREAKER (FIELD SUPPL
Y)
PEA-RP400,500GA
Q:15A
PO
WER SUPPL
Y
3N~PE 380/400/415V 50Hz
OUTDOOR UNIT
OUTDOOR UNIT
TO
OUTDOOR UNIT
CONNECTING WIRES
(POLAR)
TO
OUTDOOR UNIT
CONNECTING WIRES
(POLAR)
(No
.1)
(No
.2)
INDOOR UNIT
2
1
TB6
REMO
TE CONTR
OLLER
BO
ARD
REMO
TE CONTR
O
LLER
(No
.1)
(No
.2)
(No
.1)
INDOOR
GREEN/YELLO
W
(*1)SW2
12
2
1
4
3
OFF
ON
5
ON
OFF
SW1
5
4
3
ON
OFF
SWE
12
2
1
4
3
OFF
ON
5
ON
OFF
SW1
5
4
3
ON
OFF
SWE
49F
X02
X01
4
5
C01
52F
3
2
1
3
2
1
C02
C01
52F
L1
L2
L3
TB2
RED
WHITE
BLA
C
K
N
RED
WHITE
BLAC
K
BLUE
FUSE
51F
FUSE
FB22
FB12
TB4-1
TB4-2
TH1-2
TH2-2
TH5-2
TH5-1
TH2-1
TH1-1
t˚
t˚
t˚
X2
S3
S2
S1
FB21
X1
t˚
t˚
t˚
TB5
S3
S2
2
1
S1
FB11
1
2
2
1
2
1
4
3
2
1
CN29
CN41
CN21
CN20
DSR
DSA
CN3C
2
1
3
7
8
9
4
5
6
3
3
1
2
1
2
1
2
1
2
LED3
LED2
LED1
X6
X5
X4
3
75
1
DC13.1V
21
1
3
1
3
1
3
ZNR
54321
CN51
CN31
CN32
CND
CNDK
FA
N
CN2L
CN22
CN90
CN2D
DC
13.1V
CN2S
1
2
CNSK
1
3
DC
13.1V
CN2S
1
2
CNSK
1
3
CN3C
2
1
3
7
8
9
4
5
6
3
3
1
2
1
2
1
2
1
2
LED3
LED2
LED1
DC13.1V
21
1
3
1
3
ZNR
54321
CN51
CN31
CN32
CND
CN2L
CN22
CN90
CN2D
1
2
2
1
2
1
4
3
2
1
CN29
CN41
CN21
CN20
X6
X5
X4
3
75
1
1
3
CNDK
FA
N
TAB1
TAB1
(*1)SW2
PO
WER BO
ARD
INDOOR
SNB BO
ARD 1
(No
.2)
CONTR
OLLER BO
ARD
INDOOR
INDOOR PO
WER BO
ARD
CONTR
OLLER BO
ARD
51F
CR
ZNR5~7