Содержание Mr. Slim PU-5TJSA1

Страница 1: ...RAM 7 7 PARTS LIST 8 Outdoor unit Model names PU 5TJSA PU 6TJSA Service Ref PU 5TJSA1 PU 5TJSA2 PU 6TJSA1 PU 6TJSA2 No OC199 REVISED EDITION A Outdoor unit 2003 Revision This service manual describes only the change points Please refer to OC127 REVISED EDITION A as to excluding this manual PU 5TJSA2 and PU 6TJSA2 are added to REVISED EDITION A Please void OC199 SPLIT TYPE AIR CONDITIONERS ...

Страница 2: ......

Страница 3: ...C GJSD OC215 OC199 PU 5TJSA PU 5TJSA1 PU 6TJSA PU 6TJSA1 CHANGE POINTS 1 LP switch is added Refer to 5 WIRING DIAGRAM 6 REFRIGERANT SYSTEM DIAGRAM and 7 PARTS LIST for details 2 Combination of indoor and outdoor units are added Refer to 2 COMBINATION OF INDOOR AND OUTDOOR UNITS 3 The location of GROUND TERMINAL is changed Refer to 4 OUTLINES AND DIMENSIONS OC199 REVISED EDITION A PU 5TJSA1 PU 5TJS...

Страница 4: ...nce Piping length OUTDOOR UNIT REFRIGERANT PIPING kW A A kW kW k min CFM dB mm in mm in mm in kg lbs kg lbs L mm in mm in Notes1 Rating Conditions JIS B8616 Indoor D B 27 C 80 F W B 19 C 66 F Outdoor D B 35 C 95 F W B 24 C 75 F PU 5TJSA1 PU 5TJSA2 5 63 16 83 135 ZR61KC TF5 3 5 55 114 282 5 1 11 2 2 130 SONTEX 200LT PU 6TJSA1 PU 6TJSA2 6 15 18 70 140 ZR68KC TF5 4 0 56 117 313 5 7 12 6 1 774 SONTEX ...

Страница 5: ... outdoor unit connection Terminal block for power line with ground terminal 300 10 10 10 Note Allow adequate upper clearance 150 500 500 Service space Handle for moving 524 61 585 83 524 345 382 403 959 1258 49 1 2 90 60 524 Service panel Handle for moving Refrigerant pipe flared connection 19 05 3 4F Refrigerant pipe flared connection 9 52 3 8F Knock out hole for front piping refrigerant drainage...

Страница 6: ...S SHOW FIELD WIRING 2 TO INDOOR UNIT TERMINAL BLOCK BLK A C 63H 26C 47 PHASE PROTECTOR TB1 PHASE PROTECTOR 47 TERMINAL BLOCK CONNECTING WIRES INDOOR OUTDOOR CP TERMINAL BLOCK POWER SUPPLY COMPRESSOR FAN MOTOR FUSE 5A FAN MOTOR CAPACITOR COMPRESSOR PROTECTOR THERMAL RELAY 51C LOW PRESSURE SWITCH 63L INTERNAL THERMOSTAT FOR MC 49C 2 TO INDOOR UNIT TERMINAL BLOCK NOTES 1 THE DOTTED LINES SHOW FIELD W...

Страница 7: ...re switch Compressor Accumulator DPR Capillary tube PU 5TJSA1 O D 4 0 oI D 2 4 o400 PU 5TJSA2 PU 6TJSA1 O D 4 0 oI D 2 4 o200 PU 6TJSA2 Capillary tube PU 5TJSA1 PU 5TJSA2 O D 4 0 oI D 2 4 o840 o2pcs PU 6TJSA1 PU 6TJSA2 O D 4 0 oI D 2 4 o740 o2pcs 9 52 3 8 19 05 3 4 Check plug Charge plug flow of refrigerant Strainer Low pressure switch Strainer ...

Страница 8: ... Diagram Symbol Recom mended Q ty Price Unit Amount Remarks Drawing No BC79G510H02 DG79R130H01 Z004M203H10 5o10 TJSA TJSA1 TJSA2 TJSA TJSA1 TJSA2 PU 5 PU 6 R01 A14 668 R01 A00 675 R01 A00 655 R01 AK6 686 R01 A14 658 R01 A14 682 R01 A14 661 T7W E03 698 R01 A14 641 T7W E00 130 R01 A14 662 FRONT PANEL FAN GUARD HANDLE BASE PANEL COVER LABEL BRAND REAR PANEL SERVICE PANEL LABEL MITSUBISHI REAR GUARD T...

Страница 9: ...CHARGE PRESSURE REGULATOR CAPILLARY TUBE CHARGE PLUG CAPILLARY TUBE LOW PRESSURE SWITCH ACCUMULATOR ACCUMULATOR COMPRESSOR CONTACTOR COMPRESSOR CONTACTOR FAN MOTOR CAPACITOR PHASE PROTECTOR TERMINAL BLOCK COMPRESSOR PROTECTOR TERMINAL BLOCK FUSE HOLDER FUSE PA6N100 UE M8 CUT 3 3MPa ZR61KC TF5 3 8 3 4 4 0o 2 4o400A 4 0o 2 4o840A CUT 0 03MPa S N25EX MSO N25KF 4 440V 4P L1 L2 L3 220V 2P 1 2 250V 5A T...

Страница 10: ...CHARGE PRESSURE REGULATOR CAPILLARY TUBE CHARGE PLUG CAPILLARY TUBE LOW PRESSURE SWITCH ACCUMULATOR ACCUMULATOR COMPRESSOR CONTACTOR COMPRESSOR CONTACTOR FAN MOTOR CAPACITOR PHASE PROTECTOR TERMINAL BLOCK COMPRESSOR PROTECTOR TERMINAL BLOCK FUSE HOLDER FUSE PA6N100 UE M8 CUT 3 3MPa ZR68KC TF5 3 8 3 4 4 0o 2 4o200A 4 0o 2 4o740A CUT 0 03MPa S N25EX MSO N25KF 4 440V 4P L1 L2 L3 220V 2P 1 2 250V 5A T...

Страница 11: ......

Страница 12: ...Reprinted in Oct 2002 No OC199 5 Reprinted in Apr 2002 No OC199 50 Reprinted in Feb 2002 No OC199 5 Issued in Jul 1999 No OC199 570 Made in Japan New publication effective Nov 2002 Specifications subject to change without notice HEAD OFFICE MITSUBISHI DENKI BLDG 2 2 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN ...