background image

41

 Part number that is circled is not shown in the figure.

RU

1
1
1
5
2
1
1
1
1
1
1
1
1

1
1

R01 12G 662
R01 E00 812
R01 E01 811
R01 A17 500
R01 12G 691
R01 24K 658
T7W E05 661
R01 E00 075
R01 E01 049
T7W E06 714
R01 16G 808
R01 E00 641


R01 16G 692
R01 12G 523

1
2
3
4
5
6
7
8
9

10
11
12

13

14
15

(RG00A734GH0)
(RG00A734GH2)

Part No.

No.

Wiring

Diagram

Symbol

Recom-

mended

Q

,

ty

Remarks

(Drawing No.)

Part Name

Specification

Q,ty/set

LEFT SIDE PANEL
UNDER PLATE
NOSE
AIR FILTER
INTAKE GRILLE
RECEIVER
RIGHT SIDE PANEL
WIRELESS  REMOTE  CONTROLLER  HOLDER
WIRELESS  REMOTE  CONTROLLER  DOOR
WIRELESS  REMOTE  CONTROLLER
BACK PLATE
TOP PLATE
BOX ASSEMBLY
BOX ASSEMBLY
INTAKE GRILLE
DRAIN SOCKET

RP100FAL

1
1
1
5
2
1
1
1
1
1
1
1

1
1
1

P100FALH

PKA-

PKH-

9

10

8

7

4

2

3

11

12

1

6

13

5

STRUCTURAL PARTS
PKA-RP100FAL PKH-P100FALH

14

Содержание Mr.Slim PKA-RP100FAL

Страница 1: ... REVISED EDITION B Remote controller SPLIT TYPE HEAT PUMP AIR CONDITIONERS SPLIT TYPE AIR CONDITIONERS Note This manual describes only service data of the indoor units RoHS compliant products have G mark on the spec name plate For servicing of RoHS com pliant products refer to the RoHS Parts List Model name indication PKH P60FALH PKH P60FALH PKH P71FALH PKH P71FALH PKH P100FALH PKH P100FALH May 20...

Страница 2: ...UHZ P100 125 140VHA UK OC359 PUHZ RP35 50 60 71 100 125 140VHA2 1 PUHZ RP100 125 140YHA2 1 PUHZ RP35 50 60 71 100VHA3 PUHZ RP100YHA3 OC374 PU H P71 100VHA 1 UK PU H P100 125 140YHA 1 UK OC379 PUHZ P100 125 140VHA2 1 UK OCH415 OCB415 PUHZ RP71 100 125 140VHA2 A PUHZ RP100 125 140YHA2 A OCH422 OCB422 PUHZ BP100 125 140VHA A PUHZ BP200 250YHA A OCH423 OCB423 PUHZ P200 250YHA2 OCH424 OCB424 PUHZ HRP71...

Страница 3: ...eal the system the composition of the refrigerant in the cylinder will change and performance may drop Do not use a refrigerant other than R407C If another refrigerant R22 etc is used the chlorine in the refrigerant may cause the lubricant deterioration Use a vacuum pump with a reverse flow check valve The vacuum pump oil may flow back into the refrigerant cycle and cause the lubricant deteriorati...

Страница 4: ...frigerant recovery equipment 2 Refrigerant recharging 1 Refrigerant recharging process 1Direct charging from the cylinder R407C cylinder are available on the market has a syphon pipe Leave the syphon pipe cylinder standing and recharge it By liquid refrigerant 2 Recharge in refrigerant leakage case After recovering the all refrigerant in the unit proceed to working Do not release the refrigerant i...

Страница 5: ...ly designed for use with R410A refrigerant The following tools are necessary to use R410A refrigerant Keep the tools with care If dirt dust or moisture enter into refrigerant cycle that can cause deterioration of refrigerant oil or malfunction of com pressor Do not use a charging cylinder If a charging cylinder is used the composition of refrigera nt will change and the efficiency will be lowered ...

Страница 6: ...NF1 2 Use high tension side pressure of 5 3MPa G or over 2 Charge hose Only for R410A Use pressure performance of 5 09MPa G or over 3 Electronic scale 4 Gas leak detector Use the detector for R134a R407C or R410A 5 Adaptor for reverse flow check Attach on vacuum pump 6 Refrigerant charge base 7 Refrigerant cylinder Only for R410A Top of cylinder Pink Cylinder with syphon 8 Refrigerant recovery equ...

Страница 7: ...urrent time and timer settings h and min buttons display SET TEMP display indicates desired temperature set display FAN SPEED display indicates which fan speed has been selected display The vertical direction of air flow is indicated display Blinks when model is selected display Lights up while transmission to the indoor unit is mode using switches display CHECK TEST RUN display indicates that the...

Страница 8: ... 235 9 1 4 340 13 3 8 24 53 PKA RP50FAL2 PKA RP50FAL2 1 PKA RP60FAL PKA RP60FAL 1 kW A A kW min CFM Pa mmAq dB mm in mm in mm in mm in kg lbs Service Ref Mode Power supply phase cycle voltage Input Running current Starting current External finish Heat exchanger Fan Fan drive x No Fan motor output Airflow Low High External static pressure Operation control Thermostat Noise level Low High Unit drain...

Страница 9: ...atic pressure Booster heater 1 Operation control Thermostat Noise level Low High Unit drain pipe O D Dimensions Weight INDOOR UNIT W D H Cooling 0 09 0 43 0 80 Heating 0 09 1 93 0 43 8 39 0 80 8 39 Single phase 50Hz 230V Munsell 3 4Y 7 7 0 8 Plate fin coil Line flow direct x 2 0 040 15 20 530 706 0 direct blow 1 93 Wireless remote controller built in 39 45 20 13 16 1 400 13 16 235 9 1 4 340 13 3 8...

Страница 10: ...UENCIES Hz PKA RP50FAL2 PKA RP50FAL2 1 PKA RP60 71FAL PKA RP60 71FAL 1 PKH P60 71FALH High Low 45 SPL dB 39 LINE NOTCH UNIT WALL 1m 1m MICROPHONE 90 80 70 60 50 40 30 20 10 63 125 250 500 1000 2000 4000 8000 APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE NC 60 NC 50 NC 40 NC 30 NC 20 NC 70 OCTAVE BAND SOUND PRESSURE LEVEL dB 0dB 0 0002 μbar BAND CENTER FREQUENCIES Hz PKA RP100FAL PKA RP100F...

Страница 11: ...erant pipe Drain pipe Rear piping opening Range for left rear piping opening 12 ø6 hole for tapping screw 66 ø6 hole for tapping screw Wall fixture Unit center 32 ø12 hole for bolt 225 18 18 91 900 990 455 285 245 19 240 280 314 610 90 Drainage range on left hand side Drainage range on right hand side 10 91 910 180 Terminal block for heater PKH only Terminal block for indoor outdoor connecting lin...

Страница 12: ...65 100 A B C Knockout hole for wiring 25 1110 183 240 B 1400 55 120 102 111 694 Air outlet 694 Air outlet Louvers manual Under panel Removable at left hand side piping Knockout hole for under piping Refrigerant pipe Drain pipe Rear piping opening Range for left rear piping opening Range for left rear piping opening 84 ø6 hole for tapping screw Wall fixture Unit out line Unit center 41 ø12 hole for...

Страница 13: ...TRALLY CONTROL SW1 SWITCH MODEL SELECTION See Table 1 SW2 SWITCH CAPACITY CODE See Table 2 SWE SWITCH EMERGENCY OPERATION X4 RELAY FAN MOTOR BCR POWER SUPPLY R B LED1 POWER SUPPLY I B LED2 TRANSMISSION INDOOR OUTDOOR LED3 FAN CONTROL ELEMENT C CAPACITOR FAN MOTOR FAN MOTOR VANE MOTOR MF MV SYMBOL NAME TB4 TERMINAL BLOCK INDOOR OUTDOOR TB2 TERMINAL BLOCK HEATER PKH P FALH models only or option for ...

Страница 14: ... PKA RP100FAL 1 PKH P100FALH Pipe temperature thermistor liquid TH2 Distributor with strainer 50 Condenser evaporator temperature thermistor TH5 Room temperature thermistor TH1 Refrigerant flow in cooling Refrigerant flow in heating Strainer 50 Strainer 50 Heat exchanger Refrigerant GAS pipe connection Flare Refrigerant LIQUID pipe connection Flare ...

Страница 15: ...g to TROUBLESHOOTING BY INFERIOR PHENOMENA 10 4 The problem is not reoccurring Logged Not logged Consider the temporary defects such as the work of protection devices in the refrigerant circuit including compressor poor connection of wiring noise and etc Re check the symptom and check the installation environment refrigerant amount weather when the trouble occurred matters related to wiring and et...

Страница 16: ...Procedure 1 Press the CHECK button twice 2 Press the temperature buttons 3 Point the remote controller at the sensor on the indoor unit and press the HOUR button 4 Point the remote controller at the sensor on the indoor unit and press the ON OFF button Malfunction diagnosis method at maintenance service 10 2 MALFUNCTION DIAGNOSIS METHOD BY REMOTE CONTROLLER In case of trouble during operation When...

Страница 17: ... Number of times Wireless remote controller Wired remote controller Beeper sounds OPERATION INDICATOR lamp flashes Check code Number of times Wireless remote controller Wired remote controller 1 P1 Intake sensor error P9 Pipe TH5 sensor error 2 P2 Pipe TH2 sensor error 3 E6 E7 Indoor outdoor unit communication error 4 P4 Drain sensor error 5 P5 PA Drain pump error Forced compressor stop due to wat...

Страница 18: ...ection device is not connected Reverse or open phase wiring for the outdoor unit s power terminal block L1 L2 L3 Incorrect wiring between indoor and outdoor units incorrect polarity of S1 S2 S3 Remote controller wire short Note Operation is not possible for about 30 seconds after cancellation of function selection Correct operation For description of each LED LED1 2 3 provided on the indoor contro...

Страница 19: ...gain to operate after check Room temperature thermistor TH1 1 The unit is in 3 minute resume prevention mode if short open of thermistor is detected Abnormal if the unit does not reset normally after 3 min utes The unit returns to normal opera tion if it has been reset normally 2 Constantly detected during cooling drying and heating operation Short 90 or more Open 40 or less 1 Defective thermistor...

Страница 20: ...e 4 Defective indoor fan motor Fan motor is defective Indoor controller board is defec tive 5 Defective outdoor fan control 6 Overcharge of refrigerant 7 Defective refrigerant circuit clogs 8 Bypass circuit of outdoor unit is defective Cooling or drying mode 1 Check clogs of the filter 2 Remove shields 4 Refer to 10 7 1 5 Check outdoor fan motor 67 Check operating condition of refrigerant circuit ...

Страница 21: ... connecting remote control ler max 2 units When it is not the above mentioned problem of 1 3 4 Diagnose remote controllers a When RC OK is displayed Remote controllers have no problem Turn the power off and on again to check If abnormality generates again replace indoor controller board b When RC NG is displayed Replace remote controller c When RC E3 or ERC 00 66 is dis played noise may be causing...

Страница 22: ...Contact failure short circuit or miswiring converse wiring of indoor outdoor unit connecting wire 2 Defective transmitting receiving circuit of indoor controller board 3 Defective transmitting receiving circuit of indoor controller board 4 Noise has entered into indoor outdoor unit connecting wire Check LED display on the outdoor control circuit board Connect A control service tool PAC SK52ST Refe...

Страница 23: ...n between indoor controller board and indoor power board Check the fuse on indoor controller board If no problems are found indoor controller board is defective When LED1 on indoor controller board is lit 1 Mis setting of refrigerant address for outdoor unit There is no unit corresponding to refrigerant address 0 1 Reconfirm the setting of refrigerant address for outdoor unit Set the refrigerant a...

Страница 24: ...r wires 4 Defective remote controller Check indoor outdoor unit connecting wire for connection failure 1 Check the connection of remote con troller wires in case of twin triple indoor unit system When 2 or more indoor units are wired in one refrigerant system connect remote controller wires to one of those units 2 Check the setting of refrigerant address in case of grouping control system If there...

Страница 25: ...me as cold air is blown when the outdoor unit starts defrosting operation during heat emer gency operation 4 Cool emergency operation must be within 10 hours at most It may cause heat exchanger frosting in the indoor unit 5 After completing the emergency operation return the switch setting etc in former state 6 Since vane does not work at emergency operation position the vane manually and slowly 1...

Страница 26: ...a tester Heater Only PKH Normal Abnormal 60 71 18 9 700W 240V 100 16 5 800W 240V Open or short Disconnect the connector then measure the resistance with a tester Surrounding temperature 10 30 Room temperature thermistor TH1 Pipe temperature thermistor TH2 Condenser evaporator temperature thermistor TH5 Normal 4 3k 9 6k Abnormal Open or short Normal 0 10 20 30 40 50 20 10 0 10 20 30 40 50 Thermisto...

Страница 27: ...tor Liquid TH2 CN20 Room temperature thermistor TH1 CN41 Connector HA terminal A CN6V Vane motor output MV CN90 Connect to the wireless remote controller board CNB CN31 Drain sensor DS CN51 Centrally control CN29 Condenser evaporator temperature thermistor TH5 CN24 Heater output 12V DC SW1 Model setting SW2 Capacity setting SWE Emergency operation LED1 Power supply I B LED2 Power supply R B LED3 T...

Страница 28: ...FAL PKA RP60FAL 1 PKH P60FALH PKA RP71FAL PKA RP71FAL 1 PKH P71FALH PKA RP100FAL PKA RP100FAL 1 PKH P100FALH CNSK Connect to the indoor controller board CNDK Between 1 to 3 220 240V AC CN2S Connect to the indoor controller board CN2D Between 1 to 3 12 6 13 7V DC Pin1 ...

Страница 29: ... in the table on the left in the table indicates the jumper line is disco nnected There is no jumper JP1 because these models have the cond eva temperature thermistor TH5 Marks in the table below Jumper wire Short Open Without TH5 With TH5 Model JP1 For product Service parts Indoor controller board type JP3 1 2 3 4 5 ON OFF Models PKA RP60FAL PKH P60FALH PKA RP50FAL2 PKA RP71FAL PKH P71FALH 1 2 3 ...

Страница 30: ...e interval of rotation setting w Main and sub unit should be set by refrigerant address Outdoor Dip switch setting Refrigerant address 00 Main unit Refrigerant address 01 Sub unit When error occurrs to one unit another unit will start operation Back up function System constraint This function is available only by the grouping control system INDOOR UNIT OUTDOOR UNIT 1 1 of 2 refrigerant groups Refe...

Страница 31: ... interval 1day and back up function No 5 314 Rotation ON Alternating interval 3day and back up function No 6 315 Rotation ON Alternating interval 5day and back up function No 7 316 Rotation ON Alternating interval 7day and back up function No 8 317 Rotation ON Alternating interval 14day and back up function No 9 318 Rotation ON Alternating interval 28day and back up function Setting No Request cod...

Страница 32: ...ars on the screen when Maintenance monitor is activated The display now allows you to set a request code No 4 Press the TEMP and buttons to select the desired refrigerant address 5 Press the CLOCK and buttons to set the desired request code No 311 318 321 324 6 Press the button to perform function setting If above setting operations are done correctly Request code number will appear in data displa...

Страница 33: ...ntroller board 4 To unhook the catches on the right hand side of the indoor controller board pull the left hand side toward you and lift up the cover to the right Then the indoor controller board can be removed 4 Removing the electrical parts box 1 Remove the right side panel 2 Remove the screw of the electrical parts box cover and remove the cover 3 Remove the room temperature thermistor and the ...

Страница 34: ...nhook the catch on the panel from the catch on the unit 2 Slide the left side panel to the left to remove the panel Note Fix the unit to the metal fixture securely 3 Remove the air filters 4 Hold and press the centre cover to remove 5 Remove the screws of the grilles 6 Pull the lower side of the grille toward you and slide the upper to the right to remove the grilles 7 Removing the drain pan 1 Rem...

Страница 35: ...w fans Photo 9 Photo 11 Photo 8 Photo 7 Screw Motor support Motor support Screw Fan motor Motor fixture Fan motor Screw Screw Fan motor Line flow fan Lineflow fan Bearing support Heat exchanger 8 Removing the line flow fan and the fan motor 1 Remove the left and right side panels 2 Remove the grilles 3 Remove the electrical parts box 4 Remove the drain pan 5 Loosen the screw that fixes the line fl...

Страница 36: ...T LINEFLOW FAN 1 1 3 T7W E57 480 HEAT EXCHANGER 1 R01 E61 480 HEAT EXCHANGER 1 R01 E62 480 HEAT EXCHANGER 1 1 4 T7W E13 529 DRAIN PAN 1 1 1 1 5 GUIDE VANE 16 16 16 16 BG25J821H01 6 ARM 3 3 3 3 BG25H301H02 7 R01 12G 621 CENTER COVER 1 1 1 1 8 R01 12G 063 JOINT SHAFT 1 1 1 1 9 R01 12G 002 AUTO VANE 2 2 2 2 10 R01 KV5 527 DRAIN HOSE 1 1 1 1 11 GUIDE VANE 4 4 4 4 BG25J821H02 12 R01 E05 223 VANE MOTER ...

Страница 37: ...IGHT LINEFLOW FAN CENTER SUPPORT BEARING BAND BEARING MOUNT SLEEVE BEARING FAN GUARD MOTOR LEG HEATER THERMAL SWITCH THERMAL FUSE HEATER SLEEVE BEARING INSULATOR 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 2 1 1 1 3 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 2 1 1 1 3 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 2 1 1 250V 6 3A JC 1A DC12V 3P S1 S2 S3 3P L N PN4S40 K 70 C...

Страница 38: ...16G 114 LEFT LINEFLOW FAN 1 R01 17G 114 LEFT LINEFLOW FAN 1 3 T7W E22 480 HEAT EXCHANGER 1 T7W E58 480 HEAT EXCHANGER 1 4 T7W E14 529 DRAIN PAN 1 1 5 GUIDE VANE 22 22 BG25J821H01 6 ARM 4 4 BG25H301H02 7 R01 12G 621 CENTER COVER 1 1 8 R01 12G 063 JOINT SHAFT 1 1 9 R01 16G 002 AUTO VANE 2 2 10 R01 KV5 527 DRAIN HOSE 1 1 11 GUIDE VANE 4 4 BG25J821H02 12 R01 E05 223 VANE MOTER 1 1 MV 13 R01 E03 317 WI...

Страница 39: ...N MOTOR RUBBER MOUNT MOTOR BAND RIGHT LINEFLOW FAN RIGHT LINEFLOW FAN CENTER SUPPORT BEARING BAND BEARING MOUNT SLEEVE BEARING FAN GUARD MOTOR LEG HEATER THERMAL SWITCH THERMAL FUSE HEATER SLEEVE BEARING INSULATOR 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 2 1 1 1 3 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 2 1 1 250V 6 3A JC 1A DC12V 3P S1 S2 S3 3P L N PN4S70 K 70 C OFF 50 C ON 117 C 16A 250V 240V 800W BG...

Страница 40: ... 14 RG00A734GG9 RG00A734GH1 Part No No Wiring Diagram Symbol Recom mended Q ty Remarks Drawing No Part Name Specifications Q ty set LEFT SIDE PANEL UNDER PLATE NOSE AIR FILTER INTAKE GRILLE RECEIVER RIGHT SIDE PANEL WIRELESS REMOTE CONTROLLER HOLDER WIRELESS REMOTE CONTROLLER DOOR WIRELESS REMOTE CONTROLLER BACK PLATE TOP PLATE BOX ASSEMBLY BOX ASSEMBLY DRAIN SOCKET PKH PKA RP60FAL RP71FAL P60FALH...

Страница 41: ...34GH0 RG00A734GH2 Part No No Wiring Diagram Symbol Recom mended Q ty Remarks Drawing No Part Name Specification Q ty set LEFT SIDE PANEL UNDER PLATE NOSE AIR FILTER INTAKE GRILLE RECEIVER RIGHT SIDE PANEL WIRELESS REMOTE CONTROLLER HOLDER WIRELESS REMOTE CONTROLLER DOOR WIRELESS REMOTE CONTROLLER BACK PLATE TOP PLATE BOX ASSEMBLY BOX ASSEMBLY INTAKE GRILLE DRAIN SOCKET RP100FAL 1 1 1 5 2 1 1 1 1 1...

Страница 42: ... 480 HEART EXCHANGER 1 1 G R01 K49 480 HEART EXCHANGER 1 1 1 G R01 K50 480 HEART EXCHANGER 1 1 1 4 G T7W E24 529 DRAIN PAN 1 1 1 1 1 1 1 1 5 G GUIDE VANE 16 16 16 16 16 16 16 16 BG25J821G01 6 G ARM 3 3 3 3 3 3 3 3 BG25H301G01 7 G R01 14G 621 CENTER COVER 1 1 1 1 1 1 1 1 8 G R01 13G 063 JOINT SHAFT 1 1 1 1 1 1 1 1 9 G R01 18G 002 AUTO VANE 2 2 2 2 2 2 2 2 10 G R01 E04 527 DRAIN HOSE 1 1 1 1 1 1 1 1...

Страница 43: ...VE BEARING FAN GUARD MOTOR LEG HEATER THERMAL SWITCH THERMAL FUSE HEATER SLEEVE BEARING INSULATOR 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 2 1 1 1 3 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 2 1 1 1 3 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 2 1 1 250V 6 3A JC 1A DC12V 3P S1 S2 S3 3P L N PN4S40 K 70 C OFF 50 C ON 117 C 10A 2...

Страница 44: ...4 LEFT LINEFLOW FAN 1 1 3 G T7W H35 480 HEART EXCHANGER 1 G T7W H38 480 HEART EXCHANGER 1 1 4 G T7W E25 529 DRAIN PAN 1 1 1 5 G GUIDE VANE 22 22 22 BG25J821G01 6 G ARM 4 4 4 BG25H301G01 7 G R01 14G 621 CENTER COVER 1 1 1 8 G R01 13G 063 JOINT SHAFT 1 1 1 9 G R01 19G 002 AUTO VANE 2 2 2 10 G R01 E04 527 DRAIN HOSE 1 1 1 11 G GUIDE VANE 4 4 4 BG25J821G02 12 G R01 E15 223 VANE MOTER 1 1 1 MV 13 G R01...

Страница 45: ... G R01 H06 202 PIPE TEMPERATURE THERMISTOR 1 1 1 TH2 27 G MOTOR BAND 1 1 1 BG02H065H01 28 G T7W E24 762 FAN MOTOR PN4S70 K 1 1 1 MF 29 G R01 16G 105 RUBBER MOUNT 2 2 2 30 G MOTOR BAND 1 1 1 BG02H178H01 31 G R01 19G 115 RIGHT LINEFLOW FAN 1 1 G R01 E05 115 RIGHT LINEFLOW FAN 1 32 G CENTER SUPPORT 1 1 1 BG00R259G07 33 G BEARING BAND 1 1 1 BG02L462H02 34 G R01 KV5 102 BEARING MOUNT 1 1 1 35 G R01 E03...

Страница 46: ...RU 7 G T7W E18 661 RIGHT SIDE PANEL 1 1 1 8 G R01 E00 075 WIRELESS REMOTE CONTROLLER HOLDER 1 1 1 9 G R01 E03 049 WIRELESS REMOTE CONTROLLER DOOR 1 1 1 10 G T7W E10 714 WIRELESS REMOTE CONTROLLER 1 1 1 11 G R01 E03 808 BACK PLATE 1 1 1 12 G R01 E19 641 TOP PLATE 1 1 1 13 G BOX ASSEMBLY 1 1 RG00A734GP5 G BOX ASSEMBLY 1 RG00A734GP7 14 G R01 E02 523 DRAIN SOCKET 1 1 1 RoHS Part number that is circled...

Страница 47: ...G T7W E18 661 RIGHT SIDE PANEL 1 1 1 8 G R01 E00 075 WIRELESS REMOTE CONTROLLER HOLDER 1 1 1 9 G R01 E03 049 WIRELESS REMOTE CONTROLLER DOOR 1 1 1 10 G T7W E10 714 WIRELESS REMOTE CONTROLLER 1 1 1 11 G R01 E04 808 BACK PLATE 1 1 1 12 G R01 E20 641 TOP PLATE 1 1 1 13 G BOX ASSEMBLY 1 1 RG00A734GP6 G BOX ASSEMBLY 1 RG00A734GP8 14 G R01 18G 692 INTAKE GRILLE 1 1 1 15 G R01 E02 523 DRAIN SOCKET 1 1 1 ...

Страница 48: ...ITSUBISHI ELECTRIC ENGINEERING CO LTD Distributed in May 2008 No OC331 REVISED EDITION B PDF 7 Distributed in Jun 2006 No OC331 REVISED EDITION A PDF 8 Distributed in May 2005 No OC331 PDF 9 Made in Japan New publication effective May 2008 Specifications subject to change without notice TM ...

Отзывы: