background image

16

X

 Filter removal

 Caution:

•  In removing the filter, precautions must be taken to protect your 

eyes from dust. Also, if you have to climb up on a stool to do the 
job, be careful not to fall.

•  When the filter is removed, do not touch the metallic parts inside 

the indoor unit, otherwise injury may result.

 PKA-RP·KAL

1

 Using both hands, pull both the bottom corners of the inlet grille to 

open the grille, then lift the filter until it clicks at the stop position.

2

 Hold the knobs on the filter and pull the filter up, then pull it out 

downward.
(Located in two places, on the left and right.)

A

 

Front grille

Filter

9. Emergency Operation for Wireless Remote-controller

ON/OFF 

TEMP.

°C

°C

FILTER

 Indicates that the filter needs cleaning.

  Clean the filter.

 When resetting “FILTER” display

  When the [FILTER] button is pressed two times successively after 

cleaning the filter, the display goes off and is reset.

Note:

 

When two or more different types of indoor unit are controlled, the 
cleaning period differs with the type of filter. When the master unit 
cleaning period arrives, “FILTER” is displayed. When the filter display 
goes off, the cumulative time is reset.

 

“FILTER” indicates the cleaning period when the air conditioner was used 
under general indoor air conditions by criteria time. Since the degree 
of dirtiness depends on the environmental conditions, clean the filter 
accordingly.

 

The filter cleaning period cumulative time differs with the model.

 

This indication is not available for wireless remote controller.

X

 Cleaning the filters

•  Clean the filters using a vacuum cleaner. If you do not have a vacuum 

cleaner, tap the filters against a solid object to knock off dirt and dust.

•  If the filters are especially dirty, wash them in lukewarm water. Take 

care to rinse off any detergent thoroughly and allow the filters to dry 
completely before putting them back into the unit.

 Caution:

•  Do not dry the filters in direct sunlight or by using a heat source, 

such as an electric heater: this may warp them.

•  Do not wash the filters in hot water (above 50°C), as this may 

warp them.

•  Make sure that the air filters are always installed. Operating the 

unit without air filters can cause malfunction.

 Caution:

•  Before you start cleaning, stop operation and turn OFF the power 

supply. 

•  Indoor units are equipped with filters to remove the dust of sucked-

in air. Clean the filters using the methods shown in the following 
sketches.

10. Care and Cleaning

 PKA-RP·KAL

[Combination Cooling and Heating Models]

[Cooling Only Models]

Operation Monitor Display

GREEN

ORANGE

STOP

{

{

The display will appear orange for 5 
seconds following the switch operation 
as indicated at the left, and then it will 
return to the regular display.

COOL

z

{

HEAT

z

z

{

 Turning off 

z

 Lighting

* Operation details at the time of emergency operation are as shown 

below.

Operation Mode

COOL

HEAT

Set Temperature 

24°C

24°C

Fan Speed

High

High

Airflow Direction Up and Down

Setting 1

Setting 4(5)

Cooling

Heating

Stop

Cooling

Stop

When the remote controller cannot be used

When the batteries of the remote controller run out or the remote 
controller malfunctions, the emergency operation can be done using the 
emergency buttons on the grille.

A

  DEFROST/STAND BY lamp (Orange)

B

  Operation lamp (Green)

C

  Emergency operation switch (cooling/heating)

D

 Receiver

•  Each press of the emergency operation switch will toggle the 

operation mode.

•  Check “COOL/HEAT” with the operation monitor display. (The display 

will appear orange for 5 seconds after the switch operation.)

B

A

C

B

A
D

Содержание Mr.SLIM PKA-RP KAL

Страница 1: ......

Страница 2: ...the air discharged from the unit Incomplete combustion may result Do not remove the front panel or the fan guard from the outdoor unit when it is running Symbols used in the text Warning Describes precautions that should be observed to prevent danger of injury or death to the user Caution Describes precautions that should be observed to prevent damage to the unit Symbols used in the illustrations ...

Страница 3: ...f timer is set shows the time remaining Louver display Indicates the action of the swing louver Does not appear if the louver is stationary Power On indicator Indicates that the power is on Fan Speed indicator Shows the selected fan speed Ventilation indicator Appears when the unit is running in Ventilation mode Sensor indicator Displayed when the remote controller sensor is used Locking function ...

Страница 4: ...ly Do not drop the remote controller or subject it to strong shocks In addition do not get the remote controller wet or leave it in a location with high humidity To avoid misplacing the remote controller install the holder included with the remote controller on a wall and be sure to always place the remote controller in the holder after use For explanation purposes all of the items that appear in ...

Страница 5: ...l Screens View and set the air conditioning system s operating status Timer Monitor View the currently set timer weekly timer simple timer or Auto Off timer Timer Setup Set the operation of any of the timers weekly timer simple timer or Auto Off timer How to change the screen A Hold down both the Operation mode button and the Timer On Off button for 2 seconds B Press the Timer Menu button C Press ...

Страница 6: ...m temperature once the temperature is reached automatic energy saving operation 5 3 Temperature setting To decrease the room temperature Press button 3 to set the desired temperature The selected temperature is displayed 3 To increase the room temperature Press button 3 to set the desired temperature The selected temperature is displayed 3 Available temperature ranges are as follows Cooling Drying...

Страница 7: ...e when room temperature is higher than the temperature setting Manual To Change the Airflow s Left Right Direction The louver button 7 cannot be used Model PKA RP KA Stop the unit operation hold the lever of the louver and adjust to the desired direction Do not set to the inside direction when the unit is in the cooling or drying mode because there is a risk of condensation and water dripping Caut...

Страница 8: ...imer Menu button b so that the Set Up appears on the screen at 2 Note that each press of the button toggles the display between Set Up and Monitor 3 Press the Timer On Off Set Day button 9 to set the day Each press advances the display at 3 to the next setting in the following sequence Sun Mon Tues Wed Thurs Fri Sat Sun Fri Sat Sun Mon Tues Wed Thurs Fri Sat 4 Press the or operation button 7 or 8 ...

Страница 9: ...TER CHECK OPERATION CLEAR TEST TEMP MENU BACK DAY MONITOR SET CLOCK ON OFF 2 a 9 0 4 1 b ON Hr AFTER SIMPLE 4 1 3 2 Timer Setting Action On or Off is displayed if there is no setting C C TIME SUN WEEKLY 0 6 Timer Timer Settings C TIMER SUN ON OFF WEEKLY 1 9 8 C C TIME SUN WEEKLY 0 7 Press the appropriate Temperature set button 3 to set the desired temperature at 7 Each press changes the setting in...

Страница 10: ...roller see 8 4 3 3 timer function setting 2 Hold down the Timer Menu button b for 3 seconds so that the Set Up appears on the screen at 2 Note that each press of the button toggles the display between Set Up and Monitor 3 Press the appropriate Set Time button a as necessary to set the OFF time at 3 4 Press the Filter button 4 to lock in the setting Note Your entry will be cancelled if you press th...

Страница 11: ...r mode to stop the unit will cancel the timers If the current time has not been set the timer operation cannot be used 7 Other Functions C C TIME SUN FUNCTION PAR 21MAA ON OFF FILTER CHECK OPERATION CLEAR TEST TEMP MENU BACK DAY MONITOR SET CLOCK ON OFF 4 1 1 Locking function indicator 7 1 Locking the Remote Controller Buttons Operation function limit controller If you wish you can lock the remote...

Страница 12: ...ting main or sub remote controller When two remote controllers are connected to one group one controller must be set to sub 2 Use of clock setting CLOCK Setting the use or non use of clock function 3 Timer function setting WEEKLY TIMER Setting the timer type 4 Contact number setting for error situation CALL Contact number display in case of error Setting the telephone number 4 Display change DISP ...

Страница 13: ...nction setting is not used Initial setting value Operation lock setting is except On Off button Operation lock setting is All buttons The automatic mode is displayed when the operation mode is selected Initial setting value The automatic mode is not displayed when the operation mode is selected The temperature range limit is not active Initial setting value The temperature range can be changed on ...

Страница 14: ...mit setting press the button H The selected setting will flash and the temperature can be set Settable range Cool Dry mode Lower limit 19 C 30 C Upper limit 30 C 19 C Heat mode Lower limit 17 C 28 C Upper limit 28 C 17 C Automatic mode Lower limit 19 C 28 C Upper limit 28 C 19 C 8 Function Selection 4 3 Operation mode selection setting 1 Remote controller main sub setting To switch the setting pre...

Страница 15: ...HANGE LANGUAGE Function selection Operation function limit setting Use of automatic mode setting Temperature range limit setting Limit temperature cool day mode Limit temperature heat mode Limit temperature auto mode Operation mode selection Remote controller setting MAIN Remote controller setting SUB Use of clock setting Setting the day of the week and time Timer set Timer monitor Weekly timer Ti...

Страница 16: ...knock off dirt and dust If the filters are especially dirty wash them in lukewarm water Take care to rinse off any detergent thoroughly and allow the filters to dry completely before putting them back into the unit Caution Do not dry the filters in direct sunlight or by using a heat source such as an electric heater this may warp them Do not wash the filters in hot water above 50 C as this may war...

Страница 17: ...g defrosting mode cool airflow may blow down and appear like a mist Water or vapor is emitted from the outdoor unit During cool mode water may form and drip from the cool pipes and joints During heat mode water may form and drip from the heat exchanger During defrosting mode water on the heat exchanger evaporates and water vapor may be emitted The operation indicator does not appear in the remote ...

Страница 18: ... batteries and press the Reset button If nothing appears even after the batteries are replaced make sure that the batteries are installed in the correct directions The operation lamp near the receiver for the wireless remote controller on the indoor unit is flashing The self diagnosis function has operated to protect the air conditioner Do not attempt to repair this equipment by yourself Turn off ...

Страница 19: ......

Страница 20: ...e be sure to put the contact address telephone number on this manual before handing it to the customer HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN Printed in Thailand RG79D344H01 ...

Отзывы: