background image

Air-Conditioners

PEAD-RP·EA PUHZ-RP·HA
PEAD-RP·GA PU(H)-P·GAA

OPERATION MANUAL

For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit.

BEDIENUNGSHANDBUCH

Zum sicheren und einwandfreien Gebrauch der Klimaanlage dieses Bedienungshandbuch vor Inbetriebnahme
gründlich durchlesen.

MANUEL D’UTILISATION

Pour une utilisation correcte sans risques, veuillez lire le manuel d’utilisation en entier avant de vous servir du
climatiseur.

DRIFTSMANUAL

Läs denna driftsmanual noga för säkert och korrekt bruk innan luftkonditioneringen används.

BEDIENINGSHANDLEIDING

Voor een veilig en juist gebruik moet u deze bedieningshandleiding grondig doorlezen voordat u de
airconditioner gebruikt.

ISTRUZIONI DI FUNZIONAMENTO

Leggere attentamente questi istruzioni di funzionamento prima di avviare l’unità, per un uso corretto e sicuro
della stessa.

MANUAL DE INSTRUCCIONES

Lea este manual de instrucciones hasta el final antes de poner en marcha la unidad de aire acondicionado
para garantizar un uso seguro y correcto.

MANUAL DE OPERAÇÃO

Para segurança e utilização correctas, leia atentamente o manual de operação antes de pôr a funcionar a
unidade de ar condicionado.

DRIFTSMANUAL

Læs venligst denne driftsmanual grundigt før airconditionanlægget betjenes af hensyn til sikker og korrekt brug.

E°XEIPI¢IO O¢H°IøN XPH™Eø™

°È· ·ÛÊ¿ÏÂÈ· Î·È ÛˆÛÙ‹ ¯Ú‹ÛË, ·Ú·Î·Ï›ÛÙ ‰È·‚¿ÛÂÙ ÚÔÛ¯ÙÈο ·˘Ùfi ÙÔ ÂÁ¯ÂÈÚ›‰ÈÔ ¯Ú‹Ûˆ˜ ÚÈÓ ı¤ÛÂÙ ÛÂ
ÏÂÈÙÔ˘ÚÁ›· ÙË ÌÔÓ¿‰· ÎÏÈÌ·ÙÈÛÌÔ‡.

Iflletme Elkitab›

Emniyetli ve do¤ru biçimde nas›l kullan›laca¤›n› ö¤renmek için lütfen klima cihaz›n› iflletmeden önce bu
elkitab›n› dikkatle okuyunuz.

РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ

Для обеспечения правильного и безопасного использования следует ознакомиться с инструкциями,
указанными в данном руководстве по эксплуатации, тщательным образом до того, как приступать к
использованию кондиционера.

FOR USER

FÜR BENUTZER

POUR L’UTILISATEUR

FÖR ANVÄNDAREN

VOOR DE GEBRUIKER

PER L’UTENTE

PARA EL USUARIO

PARA O UTILIZADOR

TIL BRUGER

°π∞ ∆√¡ Ã∏™∆∏

KULLANICI ‹Ç‹N

ДЛЯ ПОЛЬЗОВАТЕЛЯ

English

Deutsch

Français

Nederlands

Español

Italiano

∂ÏÏËÓÈο

Português

Dansk

Svenska

Türkçe

Русский

Содержание Mr. Slim PEAD-RP EA

Страница 1: ... de poner en marcha la unidad de aire acondicionado para garantizar un uso seguro y correcto MANUAL DE OPERAÇÃO Para segurança e utilização correctas leia atentamente o manual de operação antes de pôr a funcionar a unidade de ar condicionado DRIFTSMANUAL Læs venligst denne driftsmanual grundigt før airconditionanlægget betjenes af hensyn til sikker og korrekt brug E XEIPI IO O H IøN XPH Eø È ÛÊ ÏÂ...

Страница 2: ...e a gas heater or any other open flame appliance where it will be exposed to the air discharged from the unit Incomplete combustion may result Do not remove the front panel or the fan guard from the outdoor unit when it is running When you notice exceptionally abnormal noise or vibration stop operation turn off the power switch and contact your dealer Never insert fingers sticks etc into the intak...

Страница 3: ...n Start running after the HO display has disappeared The HO display briefly appears on the room temperature display max 3 minutes when the power is turned on and after a power failure This does not indicate any failure of the air conditioner The operation modes of the indoor units cooling operation dry opera tion and heating operation are different from those of the outdoor units When the operatio...

Страница 4: ...mperature rise of the blown out air Wait a moment until the airflow comes out naturally The fan is not moving at the set speed In some models the system switches over to faint airflow when the temperature of the room reaches the set temperature In other cases 2 Operation it stops to prevent any cool air from escaping during the defrosting operation Air flows out even if operation is stopped Approx...

Страница 5: ...ime When using it as an off timer set the starting time to The is displayed next to 23 50 4 Press the 4 4 4 4 4 time selection button and bring up the A A A A A Timer end time display 5 Press the 4 4 4 4 4 button of the time switch and set the ending time When using it as an on timer set the ending time to The is displayed next to 23 50 6 Press the 2 2 2 2 2 timer continuous button and bring up th...

Страница 6: ...oving the air filter Be sure to check on the location and the way of setting with the contractor when the unit performs a trial run A Air intake B Filter C Screw Only RP EA Cleaning filters Air filter cleaning method varies according to filter material Read in struction concerning filter material and cleaning method carefully Gen eral method for cleaning filters is shown below Tap lightly or clean...

Страница 7: ...ere is a simple solution to your problem NOTE After a power cut the unit will not restart automatically You will have to restart it by pressing the POWER ON OFF button on the remote controller If none of the above apply turn the main switch off and contact the dealer from whom you bought the air conditioner telling him the model name and the nature of the problem Do not try to fix the unit yoursel...

Страница 8: ... 7 CDB 6 CWB 2 GA model 50 Pa 230 V RP1 6 2 5EA model 30 Pa 230 V RP3 6EA model 70 Pa 230 V RP2EA 5 60 6 30 2 53 2 20 295 935 700 13 5 17 36 40 35 RP2 5EA 6 60 7 15 2 65 2 36 295 1175 700 17 21 37 41 42 RP2 5GA 6 60 7 15 2 74 2 50 275 1171 16 5 21 35 40 42 RP3EA 325 1175 44 RP3GA 275 1171 42 RP4EA 3 83 4 00 325 1415 27 34 41 46 62 RP4GA 3 68 3 67 275 1411 26 5 33 42 45 60 RP5EA 12 20 14 00 4 87 4 ...

Страница 9: ... Electromagnetic Compatibility Directive 89 336 EEC This product is designed and intended for use in the residential commercial and light industrial environment HEAD OFFICE MITSUBISHI DENKI BLDG 2 2 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN Printed in UNITED KINGDOM WT04004X04 The product at hand is based on the following EU regulations ...

Страница 10: ......

Отзывы: