Job Name:
Location:
Date:
Purchaser:
Engineer:
Submitted to:
For Reference Approval Construction
System Designation:
Schedule No.:
Cooling Capacity*
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .6,000 Btu/h
Heating Capacity*
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .7,200 Btu/h
*
Rating Conditions (Cooling) - Indoor: 80ºF (27ºC) DB, 67ºF (19ºC) WB; Outdoor: 95ºF
(35ºC) DB, 75ºF (24ºC) WB.
(Heating at 47ºF) - Indoor: 70ºF (21ºC) DB, 60ºF (16ºC) WB; Outdoor: 47ºF (8ºC) DB, 43ºF (6ºC) WB.
(For data on specifi c indoor units [all ducted, all non-ducted, and both ducted
and non-ducted] combinations, see the MXZ-B Technical and Service Manual.)
Electrical Requirements
Power Supply . . . . . . . . . . . . . . . . . . . . 208 / 230V, 1-Phase, 60 Hz
MCA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 A
Voltage
Indoor - Outdoor S1-S2 . . . . . . . . . . . . . . . . . . . . . . AC 208 / 230V
Indoor - Outdoor S2-S3 . . . . . . . . . . . . . . . . . . . . . . . . . DC 12-24V
Indoor - Remote Controller. . . . . . . . . . . . . . . . . . . . . . . . . Wireless
(Optional Wired Controller: DC 12V)
Fan Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.76 F.L.A.
Airfl ow (Quiet - Lo - Med - Hi - Super Hi)
Cooling . . . . . . . . . . . . . . . . . . . . .145 - 170 - 237 - 321 - 399 Dry CFM
109 - 134 - 201 - 286 - 364 Wet CFM
Heating . . . . . . . . . . . . . . . . . . . 145 - 170 - 233 - 321 - 406 CFM
Sound Pressure Level (Quiet - Lo - Med - Hi - Super Hi)
Cooling . . . . . . . . . . . . . . . . . . . . . . . . . 19 - 22 - 30 - 37 - 43 dB(A)
Heating . . . . . . . . . . . . . . . . . . . . . . . . . 19 - 22 - 30 - 37 - 43 dB(A)
DIMENSIONS
UNIT INCHES / MM
W
31-7/16 / 799
D
9-1/8 / 232
H
11-5/8 / 295
Weight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22 lbs. / 10 kg
External Finish . . . . . . . . . . . . . . . . . . . . . . Munsell No. 1.0Y 9.2 / 0.2
Field Drainpipe Size O.D.. . . . . . . . . . . . . . . . . . . . . . 5/8" / 15.88 mm
Remote Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Wireless
(Optional Wired Remote Controller PAR-21MAA;
see Data Submittal Sheet)
Refrigerant Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .R410A
Refrigerant Pipe Size O.D.
Gas Side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3/8" / 9.52 mm
Liquid Side. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/4" / 6.35 mm
Connection Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Flared
SUBMITTAL DATA: MSZ-GE06NA
6,000 BTU/H WALL-MOUNTED INDOOR UNIT FOR MXZ-B MULTI-ZONE HEAT-PUMP SYSTEMS
OPTIONAL ACCESSORIES
• M-NET Control Adapter (MAC-399IF)
• MA Contact Terminal Interface (MAC-397IF)
• Wired Remote Controller (PAR-21MAA; requires MAC-397IF)
• Condensate Pump (230V; SI3100-230)
• Anti-allergy Enzyme Filter (Two pieces per set; MAC-408FT-E)
GENERAL FEATURES
• Wall-mounted indoor unit
• Standard Hybrid Catechin Prefi lter is included with indoor unit
• Quiet operation
• Choice of fan speeds: Quiet, Low, Medium, High, and Super High;
Auto fan speed control also included
• Wireless remote controller is included; PAR-21MAA wired
remote controller can be installed as an option
• Indoor unit powered from outdoor unit using A-Control
• Auto restart following a power outage
• Limited warranty: fi ve years on parts and defects and seven years
on compressors
Indoor Unit: MSZ-GE06NA
Wireless Remote Controller
MXZ-B SERIES HEAT-PUMP OUTDOOR UNITS
SEZ-KD and PEAD-A24
Remote Controller PAR-21MAA - Packaged
with PCA-KA, PLA-ABA, SEZ, and PEAD
MSZ-GE06,09,12,15,18NA and MSZ-GA24NA
MXZ-B MULTI-ZONE SYSTEMS CAN INCLUDE:
• Ducted Indoor Units:
SEZ-KD09,12,15,18NA, PEAD-A24AA
• Nonducted Indoor Units:
MSZ-GE06,09,12,15,18NA, MSZ-GA24NA,
MSZ-FE09,12NA, MFZ-KA09,12,18NA,
PCA-A24KA, and PLA-A12,18,24BA
• A combination of both Ducted and Nonducted
Indoor Units
Refer to the separate submittal forms for the
MSZ-GE, MSZ-GA, MSZ-FE, SEZ-KD, PEAD,
PCA, PLA Indoor Units, and MXZ Outdoor Units.
Wireless Remote Controller -
Packaged with MSZ-GE, -GA,
-FE and MFZ-KA (Optional Wired
Remote Controller PAR-21MAA)
Outdoor Unit: MXZ-3B30NA
MSZ-FE
MFZ-KA
PCA-KA
PLA-A12,18,24BA